8
GB CY
Assembly
Pull out the mains plug.
Danger of electric shock.
The package contains an antistatic
chain which you may wish to install
at the bottom of the appliance to
avoid electrostatic charge during
operation.
1. Attach the antistatic chain (24)
to the metal hook at the bottom
of the stainless steel container
(6) (see small picture in the
middle).
2. Screw on the carrying handle
(2) with the enclosed cross-
head screws.
3. Place the feet (8a+b) on the
casing:
- The feet with the swivel cas-
tors (8a) in the sockets on the
front of the container (6)
- The feet with the wheels (8b)
with the imprinted numbers
+
into the corresponding
holes on the back of the con-
tainer (see small picture above).
4. Attach the feet using the en-
closed cross-head screws.
5. Fit the motor head (1) onto the
stainless steel container (6)
(see picture ) and fix it with
the fixing clips (10).
6. Plug the air diffuser (17) into the
blow connection (11) (bayonet
fixing).
7. Fit the accessories:
- Connect the suction hose (15)
(bayonet fixing).
- Fit the handle (16)
- Fit the telescopic suction pipe
(13).
(Press the knob on the tel-
escopic suction pipe in the
direction and separate to the
desired length).
- Fit the desired nozzle.
Do not vacuum without a filter!
To store the suction set during
breaks, push together the tel-
escopic suction hose and plug the
suction pipe holder into the socket
on the motor housing (see small
picture below).
Switching on/off
Connect the mains plug.
Do not vacuum without a filter!
(How to insert the filter is described
in the chapters “dry vacuuming“
and “wet vacuuming“).
Switching.On:
On/Off Switch (see
no. 3)
In position “
I
“
Switching.Off:
On/Off Switch (see
no. 3)
In position “
0
”
Dry vacuuming
1. For dry vacuuming, fit the pleated filter
(20) onto the filter basket on the motor
head (1). The sealing lip that curves
upward must point away from the mo-
tor head.
2. Fit the filter cover (19) and lock it with
a light turn:
Lock the filter cover
Unlock the filter cover
Summary of Contents for PNTS 1400 A1
Page 3: ...4 22 18 5 1 2 3 13 16 23 24 6 15 20 21 11 10 9 8a 8b 12 17 7 14 19...
Page 4: ...21 1 17 8b 8b 20 19 18 15 11 1 5 6 9 12 15 13 4 4 1 6 15 8b 8b 8a 8a 1 2 17 10 13 16 24 6...
Page 20: ...20 HR...
Page 29: ...29 BG 29 29 29 31 31 32 32 33 33 33 33 34 34 34 35 35 36 E 54 55 Grizzly Service Center 57...
Page 30: ...30 BG 16A FI 30 mA 57...
Page 31: ...31 BG 1 2 3 4 4 5 6 7 8a 2 8b 2 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24...
Page 32: ...32 BG 1 10 2 2 6 1 24 6 2 2 3 8a b 8a 6 8b 4 5 1 6 10 6 17 11 7 15 16 13...
Page 33: ...33 BG 3 I 3 0 1 20 1 2 19 1 20 2 21 5 6 18 1 17 15...
Page 35: ...35 BG 1400 W 230V 50 Hz II IP24 16 kPA 2 2 m3 min 4 m 23 l 15 l 6 5 kg 36 12 57...
Page 36: ...36 BG 3 15 22 23 13 16 6 6 18 20 21...
Page 37: ...37 GR CY 37 37 37 39 39 39 40 40 41 41 41 41 42 42 43 43 44 54 55 Grizzly Service Center 57...
Page 38: ...38 GR CY 16A FI 30 mA 57...
Page 39: ...39 GR CY 1 2 3 4 5 6 7 8a 2 8b 2 9 10 11 12 13 T 14 15 16 17 18 19 20 21 22 23 24 1 10 2 2 T 6...
Page 40: ...40 GR CY 1 24 6 2 2 3 B 8a b 8a 6 8b 4 5 1 6 10 6 17 11 7 15 16 13 3 I...
Page 41: ...41 GR CY 3 0 1 20 1 2 19 1 20 2 21 5 6 18 1 o 17 15 11 1...
Page 43: ...43 GR CY 1400 W 230V 50 Hz II IP24 16 kPA 2 2 m3 min 4 m 23 l 15 l 6 5 kg 36 12 57...
Page 44: ...44 GR CY ON OFF 3 15 22 23 13 16 6 6 18 20 21...