down.
There is a risk of burning. Do
not use coolants or the like.
•
Always empty the dust con-
tainer before work breaks.
Sanding dust in the dust sack, micro
filter, paper sack (or in the filter sack or
extraction system filter) can self-ignite
under unfavourable conditions such
as flying sparks caused by grinding
metals. Particular hazards are caused
if the sanding dust is mixed with paint,
polyurethane residues or other chemi-
cal substances, or if the sanded object
is hot after long working periods.
Please check the operating manual of
your vacuum cleaner whether it is suit-
able for the suction of grinding chips.
• Connect the appliance to a power
socket with a residual current circuit
breaker of rated residual current no
more than 30 mA.
• If the supply cord of this power
tool is damaged, it must be re-
placed by a specially prepared
cord available through the ser-
vice organization.
Residual risks
Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Lung damage, if suitable respiratory
protection is not worn;
b) Cuts
c) Ear damage if working without ear pro
-
tection.
d) Eye damage if suitable eye protection
is not worn.
e) Damage to your health caused by
swinging your hands and arms when
operating the appliance for longer pe-
riods of time or if the unit is not held or
maintained properly.
Warning! During operation, this
electric tool generates an electro-
magnetic field which, under certain
circumstances, may impair the
functionality of active or passive
medical implants. To reduce the risk
of serious or lethal injuries, we re-
commend that persons with medical
implants consult their doctor and the
manufacturer of their medical im-
plant before operating the machine.
Assembly
Always disconnect the plug from
the mains socket before working.
Danger of electric shock.
Installing/changing the
sanding disc
The device is delivered with the orbital
sander disc pre-installed.
Removing pre-assembled
sanding disc:
1. Remove the 4 Phillips screws
(22).
2. Remove the pre-assembled sand-
ing disc.
Position the mounting
plate:
3. Position the movable mounting
plate (23) on the device:
The two threaded bores (24)
of the mounting plate must be
aligned with the markings (25)
on the device.
4. Check the correct position of the
felt ring (26).