PKZ 180 C3
■
20
│
GB
│
IE
♦
Insert the nozzle adapter into the lever quick
coupler and then release it .
♦
Push the nozzle adapter into the adapter
nozzle .
♦
Inflate as described above .
using the adapter nozzle
Area of use:
You can insert the adapter nozzle in a vent
valve . You will find this together with other valves
(standard valve, screw valve, . . .) on large-volume
items, for example an inflatable mattress .
♦
Press the lever quick coupler downwards to
attach it .
♦
Insert the nozzle adapter into the lever quick
coupler and then release it .
♦
Push the nozzle adapter into the adapter
nozzle .
♦
Inflate as described above .
Maintenance and cleaning
WARNING! RISK OF INJURY! Switch
the appliance off and remove the
power plug before commencing any
work to the appliance.
■
Do not use any sharp objects to clean the
appliance. Never permit fluids to penetrate
inside the appliance.
The appliance could be
damaged .
■
The appliance is maintenance-free .
■
Ensure that the appliance has cooled down
completely, otherwise there is a risk of burns .
■
The appliance must be depressurised before
all cleaning and maintenance tasks . To do this,
open the release valve until no more air
escapes .
■
Clean the appliance regularly, preferably im-
mediately after completion of the work .
■
Clean the housing with a dry cloth – do NOT
use petrol, solvents or cleaners that can attack
the plastic .
■
Ventilation openings must never be obstructed .
NOTE
►
Replacement parts not listed (such as adapter
nozzles, switch) can be ordered via our
service hotline .
NOTE
This appliance is maintenance free . Never open
the appliance . The appliance may only be re-
paired by an authorised service centre or Cus-
tomer Service . If one of the faults listed below
occurs, note the following:
♦
Disconnect the appliance from any power
supply .
♦
Allow the appliance to cool down and wait a
short while for the residual energy to neutralise .
♦
Ensure that the appliance is in good working
condition .
Troubleshooting
Fault
Solution
1 . Appliance
does not
run
1 . Check your power supply .
Check that all cables, fuses
and the mains socket are in
working order .
2 . Do not use excessively long
extension cables .
3 . Do not use the appliance
at temperatures below
+5 degrees .
4 . Avoid overheating the
motor . Allow the motor
to cool down .
2 . Working
pressure
too low
Check the seals and the non-
return valve . Replace these if
necessary .
3 . Tools do
not work
Check the hoses, quick coupler
and the tools . Replace these if
necessary .