![Parkside PHD 100 D2 Translation Of Original Operation Manual Download Page 32](http://html.mh-extra.com/html/parkside/phd-100-d2/phd-100-d2_translation-of-original-operation-manual_3879009032.webp)
32
GB
Unsuitable extension cables can
be dangerous as people can be
harmed by an electric shock!
• Protect the electric plug connections
against moisture.
• If there is a risk of flooding, fix the
plug connections in an area that is safe
from flooding.
• Ensure that the mains voltage matches
the specifications on the rating plate.
• The electrical installation shall be ac-
cording to national wiring rules.
• Connection to the mains must be car-
ried out by an experienced electrician
and meet the requirements of IEC
60364-1.
• The device must only be connected to
a mains socket via a residual-current
circuit breaker (RCD) with a rated leak-
age current of not more than 30 mA.
Fuse: at least 13 ampere.
• Before each use, check the equipment,
cable and plug for damage.
• If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer, a customer service agent
of the same or a similarly qualified per
-
son in order to prevent hazards.
• Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.
• Do not carry or fix the equipment by
the cable.
• Use only extension cables that are pro
-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the ca-
ble for damage.
• Before any work on the equipment,
during work breaks and in the case
of non-use, remove the plug from the
socket.
• Protect the pressure washer from frost
and dry running.
• Use only original accessories and do
not carry out conversion work on the
equipment.
• Please read the notes in the operating
instructions on the topic of “mainte-
nance and cleaning”. Any measures
above and beyond these, particularly
opening the equipment, are to be car-
ried out by an electrician. In the case
of repairs, always contact our service
centre.
• The washer was designed for opera-
tion with a neutral detergent based on
a biologically decomposable anionic
tenside. Other detergents or chemical
substances could impair the safety of
the washer and damage it.
• If you come into contact with cleaning
agents, rinse with plenty of clean wa-
ter.
• Water that has passed through a back-
flow preventer is classified as undrink
-
able.
• High-pressure hoses, fittings and
couplings are important for machine
safety. Use only high-pressure hoses,
fittings and couplings recommended by
the manufacturer.
• To ensure machine safety, use only
original replacement parts from the
manufacturer or replacement parts au-
thorised by the manufacturer.
Electrical safety:
Caution: to avoid accidents and
injuries from electric shocks:
• The plug and socket of an extension
cable must be water-tight!