5
NI
IE
Overview
1 Protective cap
2 Water inlet
3 Protective cap
4 Water outlet
5 On/Off switch
6 Power cable
7 Carrying handle
8 2 ixing screws
9 Filler screw
10 Draining screw
11 Adapter
12 Seal ring
13 Suction hose connection,
water inlet
14 Suction hose
15 Preilter with backlow preventer
16 Suction hose connection, preilter
Technical Data
Garden pump set .... PGPS 1100 A1
Mains connection .............230 V~, 50 Hz
Power consumption ................... 1100 W
Suction lift ....................................... 7 m
Max. discharge rate ...............4.600 l/h*
Max. discharge head (Hmax) .......... 45 m
Max. water temperature (Tmax)
...... 35 °C
Hose connection .................1“ (30.3 mm)
Safety class .......................................... I
Degree of protection .........................IPX4
Sound pressure level
(L
pA
) ................69.5 dB(A); K
pA
=3 dB(A)
Sound power level (L
WA
)
measured .. 81.6 dB(A); K
WA
=2.16 dB(A)
guaranteed .......................... 85 dB (A)
* With the included suction hose (
14),
the maximum discharge rate of the garden
pump can not be reached.
The garden pump is not suitable for con
-
tinuous duty. Continuous operation reduces
the durability and shortens the guarantee
period. This equipment is not suitable for
commercial use.
Commercial use will invalidate the guar-
antee.
The operator or user is responsible for ac
-
cidents or damage to other people or their
property.
The manufacturer shall not be liable for
damages caused by use other than for
which the equipment is intended or by in-
correct operation.
General Description
The illustration of the principal
functioning parts can be found
on the front and back foldout
pages.
Scope of Delivery
Carefully unpack the appliance and check
that it is complete:
-
Garden pump
-
Carrying handle
- 2 ixing srews
-
Suction hose
-
Seal ring (pre-mounted)
-
Adapter (pre-mounted)
- Preilter with backlow preventer
(pre-mounted)
-
Instruction Manual
Functional description
After connecting the suction and pressure
hoses and illing the garden pump with
water, it will output a deined volume of
clear water.