22
GB
If the fastener is too deep, decrease the
air pressure in steps of 0.5 bar.
Alternatively, you can speed up opera-
tion by holding the trigger
2
pressed in.
Place the air stapler on the workpiece.
Press the device onto the workpiece until
the mouth
11
touches the workpiece.
The fastener leaves the device.
As long as you keep the trigger
2
pressed, then, every time the mouth
11
touches the workpiece, then a fastener
will leave the device.
Alternatively you can also keep the
mouth
11
of the device pressed continu-
ously onto the workpiece.
Every time you press the trigger
2
one
fastener leaves the device.
In all cases you should endeavour to work
with the lowest level of air pressure. This
brings you three significant advantages:
1) You save energy,
2) You reduce the noise level,
3) You reduce the wear on the fastening
device.
Avoid triggering the fastening device when
the magazine is empty. If the fastening
device is defective or is not working
properly, disconnect it immediately from
the compressed air and hand it over to
an expert for inspection. During long
work breaks or when work has finished,
disconnect the device from the compressed
air system and ideally empty the magazine.
Protect the compressed air connections of
the fastening device and the hose lines
against contamination. Penetration of
coarse dust, chips, sand, etc. leads to leaks
and damage to the fastening device and
couplings.
NOTE:
It is also possible to carry out
fine-tuning using the knurled screw
9
.
Rotate the knurled screw
9
down, to
make the fastener go deeper into the
workpiece.
Rotate the knurled screw
9
up, to make
the fastener go less deep into the
workpiece.
Rotate the exhaust air outlet
1
, to guide
the exhaust air flow point in the direction
you want.
Disconnect the device from the compres-
sor after completing work.
z
Removing jammed staples
If a staple/nail has got stuck in the
magazine shaft, remove the compressed
air supply immediately.
Open the magazine
7
as described in
the “Load magazine” chapter.
Open the face plate
12
by pulling the
quick clamp lever for the face plate
13
in the direction of the trigger safety
catch
10
.
Remove the jammed fastener. Close the
face plate
12
by pulling the quick clamp
lever for the face plate
13
in the direction
of the exhaust air outlet
1
.
Close the magazine
7
of the air stapler,
as described in the “Load magazine”
chapter.
z
Maintenance
DANGER OF INJURY!
Always disconnect the
device from the compressed
air supply and empty the
magazine before cleaning
and/or carrying out main-
tenance work.