9
GB
Remove batteries / rechargeable batteries
if the product will not be used for a longer
period.
Risk of damage of the product
Only use the specified type of battery /
rechargeable battery!
Insert batteries / rechargeable batteries
according to polarity marks (+) and (-) on
the battery / rechargeable battery and
the product.
Use a dry lint-free cloth or cotton swab to
clean the contacts on the battery / recharge-
able battery and in the battery compart-
ment before inserting!
Remove exhausted batteries / rechargea-
ble batteries from the product immediately.
Start-up
Before first use (see fig. B)
Remove the battery compartment cover
16
on the rear side of digital manometer
1
.
Put the batteries
15
into battery compart-
ment
17
. Check the polarity of the battery
is correctly connected.
Close the battery compartment
17
by
replacing the compartment cover
16
.
Connecting the compressed
air source
Warning:
Never exceed the maximum per-
mitted operating pressure of 8 bar.
Warning:
In order to regulate the pressure,
the compressed air source must be fitted with
a pressure regulator.
Connect the product to a suitable compres-
sed air source. Now connect the supply
pipe using the quick-release connector to
the male air fitting coupler
7
on the in-
flator
5
.
Using the digital inflator
Inflating
bicycle tyre, ball, airbed, rub-
ber dinghy etc. is a noisy ope-
ration. In order to protect hearing, wear
suitable ear protection gear is required.
Always wear suitable personal protective
gear whenever is applicable by checking
the instruction manual of the product to
be inflated.
Never point
the digital inflator to people or
animal. Expelling high pressure
air to eyes will cause serious injury.
Digital manometer
functionalities (see fig. C)
Note:
The function of digital manometer is
to monitor the inflation pressure. It is not a
calibrated measurement device.
Press On / Unit / Off button
4
briefly to
switch on the digital manometer
1
.
When digital manometer
1
be switched
on, by pressing On / Unit / Off button
4
for about 5 seconds to switch it off.
To switch on the back light of LCD display
panel
2
by pressing Light / Zero button
3
briefly.
To switch off the back light of LCD display
panel
2
by pressing Light / Zero button
3
briefly.
Press briefly On / Unit / Off button
4
to
select measuring unit of bar, kgf/cm
2
, psi,
or kPa.
Press Light / Zero button
3
for about
5 seconds to reset the digital pressure
gauge
1
to zero reading.
Note:
Do not reset digital manometer whilst
measuring. Only reset it when inflator is dis-
connected from bicycle tyre or the item to be
inflated.