42
GB
Assembly
Disconnect at the plug before carry-
ing out any work on the equipment.
Risk of electric shock!
1. Check that the pleated filter
(
13) and wire filter basket
(
14) are sitting correctly and
securely.
2. Place the container lid (5) on
the metal container (10) and
close it using the seal clips (8).
3. Connect the suction hose (11).
To do this, insert the rotatable
plastic end piece (with the
printed symbol) into the
hose connection (7) and
screw it tight (bayonet con-
nection).
When assembling/detaching the suc-
tion hose, hold the black plastic end
piece and not the metal suction hose.
Twisting or bending could damage
the hose.
4. Plug the suction tube (12) onto
the rigid end piece of the suc-
tion hose (11).
Switching on/off
Connect the mains plug.
The equipment is fitted with a safety
stop, which allows operation only
with the pleated filter and wire filter
basket installed correctly.
Switching On:
On/Off Switch (see
6) In position “
I
“
Switching Off:
On/Off Switch (see
6) In position “
0
”
Operating Instructions
The vacuuming of glowing
embers and of materials that
are combustible, explosive or
harmful to health is prohib-
ited.
There is a risk of injury!
• Place the equipment on a level surface
that is not heat sensitive.
• Always use the suction tube for vacu-
uming. In case of minor contamination,
hold the suction pipe approx. 1 cm
above the ash. Remove large ash vol-
umes by directly immersing the suction
pipe.
• Vacuum only cooled ash at less than
40°C.
• When vacuuming, keep checking the
metal container and suction hose for
rises in temperature.
• In the event of a rise in temperature,
switch off the equipment and discon-
nect at the plug. Place the equipment
outside and monitor it as it cools.
• During breaks, you can place the suc-
tion hose (
12) in the suction tube
holder (
2) on the container lid.
• Always use the carry handle (
4a)
for transporting the equipment.
• The metal container may be filled to
no more than half, so the pleated filter
always remains clear.
• Empty the container outside in order
to avoid mess (see “cleaning/mainte-
nance“).
• Clean the pleated filter (
13) (see
“cleaning/maintenance“) if the suction
performance deterio rates or when the
inspection window blockage indicator
(
3) on the container lid turns red.