32 GB/IE
Note:
operation without automatic levelling will always be indi-
cated via the red LED indicator
2
.
Note:
if the product is agitated or its position is changed during
operation, the product will automatically re-level. After re-levelling
check the positions of the horizontal and vertical laser lines against
reference points to avoid errors.
Using individual lines and crossed lines
When the product is performing automatic levelling and the base
of the measurement device deviates from the horizontal by less
than 4° (green LED on), carefully press the H-button
1
to turn the
horizontal line on or off.
Or correspondingly press the V-button
4
to turn the vertical line
on or off.
Crossed lines can be locked with this product:
When the product is performing automatic levelling and the base
of the measurement device deviates from the horizontal by less than
4° (green LED on) hold down the H-button
1
until the LED indica-
tor
2
goes red. Now automatic levelling is switched off and the
crossed lines are permanently switched on - even if the base of the
measurement device deviates from the horizontal by more than 4°.
You can turn this mode off again by pressing and holding down the
H-button
1
until the LED indicator
2
goes green again. The au-
tomatic levelling system has been switched on again.
The crossed lines are turned off as soon as the base of the measuring
tool deviates from the horizontal by more than 4°, and the LED indica-
tor
2
will turn red again.