5. Hardware Setup
Before You Begin
Placement of the Brain is very important. The brain has a possibility to be mounted on a DIN rail. Brain is
not supposed to be exposed to direct weather conditions.
Before connecting Brain, ensure that the device in which the Brain is going to be embedded is
disconnected from the power supply.
5.1.
Input/output list
To connect the Parklio brain to the desired control unit, use cables up to 1mm
2
.
Table 5.1 - Input/output list
5.2.
Connecting steps
Table 5.2 - Connecting steps
10
V+
Positive power supply input
COM
Negative power supply input
ANT
Connector for external antenna
IO 0
Input/output terminal, can be configured through the mobile application
IO 1
Input/output terminal, can be configured through the mobile application
IO 2
Input/output terminal, can be configured through the mobile application
IO 3
Input/output terminal, can be configured through the mobile application
Step 1
Connect the
V+
terminal on the Parklio Brain to the
VDC (9-32VDC)
terminal on the control
unit.
Step 2
Connect the
COM
terminal on the Parklio Brain to the
COM
terminal on the control unit.
Step 3
Connect the provided antenna to the ANT connector on the Parklio Brain.
(Antenna needs to be previously mounted on the desired spot!)