    Page 21                                                Instruction manual Parker X-Flow                                         FM-1407 Rev -  7/18   

Sub-function code 

(dec) 

Name 

10 

Clear Counters and Diagnostics Register 

11 

Return Bus Message Count 

12 

Return Bus Communication Error Count 

13 

Return Bus Exception Error Count 

14 

Return Slave Message Count 

15 

Return Slave No Response Count 

16 

Return Slave NAK Count (always 0) 

17 

Return Slave Busy Count (always 0) 

18 

Return Bus Character Overrun Count 

 

 

The maximum message size for the Return Query Data sub function is 100 bytes at 9600 baud 

(200 bytes at 19200 baud and 400 bytes at 38400 baud). When this size is exceeded, 
corrupted responses may be received. 

 
Possible exception responses: 

 

01, ILLEGAL FUNCTION, in case of not-supported sub-function 

 

03, ILLEGAL DATA VALUE, in case of an incorrect value for the data field 

Report Slave ID (17) 

The Slave ID field in the response is a string with the same contents as FlowDDE parameter 1 (indent 
 version nr/serial nr). The Run Indicator Status field in this message will indicate ON when the 
device is in normal operating mode (FB_NORMAL). 
 
Possible exception responses: 

 

04, SLAVE DEVICE FAILURE, in case of an internal error 

2.5.5

 

Available parameters 

Modbus® registers (in the data model) are numbered from 1 to 65536. In a Modbus® PDU (Protocol 
Data Unit) these registers are addressed from 0 to 65535. 
 
The following table lists the most commonly used parameters. 
 

MODBUS® REGISTERS 
 
PARAMETER 
NAME 

 
PARAMETER 
TYPE 

 
ACCESS 

 
PDU 
ADDRESS 
hex 

 
REGISTER NUMBER 
 

 
REMARK 

Hex 

Dec 

Wink 

Unsigned char  W 

0x0000 

0x0001 

Value 14592 

Init/reset 

Unsigned char  RW 

0x000A 

0x000B 

11 

 

Valve output 

Unsigned int 

RW 

0x001F 

0x0020 

32 

0..32767 

Measure 

Unsigned int  

0x0020 

0x0021 

33 

 

Setpoint 

Unsigned int 

RW 

0x0021 

0x0022 

34 

 

Setpoint slope 

Unsigned int 

RW 

0x0022 

0x0023 

35 

 

Analog input 

Unsigned int 

0x0023 

0x0024 

36 

 

Setp. control 
modes 

Unsigned char  RW  

0x0024 

0x0025 

37 

 

Sensor type 

Unsigned char  RW 

 

0x002E 

0x002F 

47 

 

Capunit 

Unsigned char  RW 

 

0x002F 

0x0030 

48 

 

Fluid number 

Unsigned char  RW 

0x0030 

0x0031 

49 

 

Alarminfo 

Unsigned char  R 

0x0034 

0x0035 

53 

 

Temperature 

Unsigned int 

0x0427 

0x0428 

1064 

 

Identnumber 

Unsigned char  RW 

 

0x0E2C 

0x0E2D 

3629 

 

ContrResp 

Unsigned char  RW 

 

0x0E45 

0x0E46 

3654 

 

CycleTime 

Unsigned char  R 

0x0E4C 

0x0E4D 

3661 

 

RespStable 

Unsigned char  RW 

 

0x0E51 

0x0E52 

3666 

 

RespOpen0 

Unsigned char  RW 

 

0x0E52 

0x0E53 

3667 

 

Calibration mode 

Unsigned char  RW 

 

0x0E61 

0x0E62 

3682 

 

Monitor mode 

Unsigned char  RW 

 

0x0E62 

0x0E63 

3683 

 

Reset 

Unsigned char  W 

0x0E68 

0x0E69 

3689 

 

Sensor zero 
potmeter 

Unsigned char  RW 

 

0x0E85 

0x0E86 

3718 

 

!

Summary of Contents for X-Flow

Page 1: ......

Page 2: ...njury and or damage to the equipment Even though care has been taken in the preparation and publication of the contents of this manual we do not assume legal or other liability for any inaccuracy mist...

Page 3: ...3 Basic Operation 14 3 1 General 14 3 2 Analog operation 14 3 3 Digital communication protocol detection Flow BUS RS232 or MODBUS RS485 15 3 4 Basic RS232 Flowbus operation 15 3 5 Modbus RS485 operat...

Page 4: ...g a constant flow rate 1 3 Symbols Important information Discarding this information could cause injuries to people or damage to the Instrument or installation Helpful information This information wil...

Page 5: ...al mass flow sensor a laminar flow element which acts as a bypass a solenoid proportional control valve and a digital electronic PC board for PID control and communication There is one model 601XF for...

Page 6: ...ty to ensure compatibility there is no liability for damages accruing from the use of this manual or other sources regarding compatibility Compatibility of seals with gasses can impact reliability of...

Page 7: ...al conditions 1 calibration fluid N2 2 customer fluid Contact the factory for more information 1 5 5 Features Each instrument consists of an Analog interface a digital RS 232 interface and a digital M...

Page 8: ...he delta T sensed by the upstream and downstream temperature sensors on the capillary The transfer function between gas mass flow and signal can be described by the equation m p signal c K V Vsignal o...

Page 9: ...Units may be flushed with clean dry inert gas In case of severe contamination it may be required to clean the inside of the instrument After cleaning a recalibration is required Contact ppfinfo parke...

Page 10: ...sure of the process conditions stipulated by the customer with a minimum of 8 bar Each instrument is helium leak tested to at least 2 10 9 mbar l s Helium outboard The tested pressure is stated on the...

Page 11: ...ed It is recommended to install an in line filter or liquid separator upstream of the flow controller and if backflow can occur a downstream filter is recommended too Be aware of the pressure drop cau...

Page 12: ...ve been made according to the hook up diagram It is recommended to turn on power before applying pressure on the instrument and to switch off power after removing pressure Check fluid connections and...

Page 13: ...ing by means of using the micro switch button on top of unit is described in this manual Warm up pressurize the system and fill the instrument according to the process conditions Make sure no flow is...

Page 14: ...ode indicates to which setpoint source the controller should respond 2 2 Analog operation At analog operation following signals are available Measured value analog output Setpoint analog input The typ...

Page 15: ...age is received the instrument will answer reply to this message and stay in the detected protocol The protocol is detected The instrument will remember the detected protocol as long as the instrument...

Page 16: ...er will be translated by FlowDDE to a channel number FlowDDE and other Parker X Flow applications are available from the factory A special RS232 cable 7 03 366 can be ordered separately It consists of...

Page 17: ...e done in the following ways Using RS232 FlowDDE Off line via the RS232 communication port by means of FlowDDE This program can be used to read change parameters including the slave address baud rate...

Page 18: ...For indication of baud rate setting both LEDs will flash The flashes are called count flashes and have a pattern of 0 5 sec on 0 5 sec off Table LED indications for bus address and baud rate Green LE...

Page 19: ...itch and count red and green flashes for baud rate setting Release after desired count Counts up to max 3 and then starts at 0 again When counting failed keep switch pressed and restart counting for n...

Page 20: ...s at 19200 baud and 400 bytes at 38400 baud When this size is exceeded corrupted responses may be received Write Single Register 06 Possible exception responses 02 ILLEGAL DATA ADDRESS in case of writ...

Page 21: ...s Modbus registers in the data model are numbered from 1 to 65536 In a Modbus PDU Protocol Data Unit these registers are addressed from 0 to 65535 The following table lists the most commonly used para...

Page 22: ...705 6170 7 Model number String 14 bytes RW 0xF110 0xF1 16 0xF111 0xF11 7 61713 6171 9 Serial number String 16 bytes RW 0xF118 0xF1 1F 0xF119 0xF12 0 61721 6172 8 Manufacturer config String 16 bytes RW...

Page 23: ...t 8 bits exponent and 23 bits fraction The first register contains bit 32 16 the second register contains bit 15 0 String parameters can have a length of maximal 16 bytes and can take up to 8 Modbus r...

Page 24: ...cations using micro switch button at normal running mode of an instrument LED s Time Pushed Indication Green Red off Off 0 4 sec No action Pressing a switch shortly by accident will not cause unwanted...

Page 25: ...ime Handling Green Red Green amount of count flashes 0 2 Off 0 2 sec maximu m tens in control mode number off amount of count flashes 0 9 0 2 sec maximu m units in control mode number 2 8 LED indicati...

Page 26: ...to 64 See Chapter 4 1 1 General Product Information for more details Range Some parameters only accept values within a certain range x Minimal value of the range y Maximal value of the range FlowDDE...

Page 27: ...the particular time frame of a protocol then it will immediately switch to this protocol for 660 ms If a valid message is received the instrument will answer reply to this message and stay in the dete...

Page 28: ...en 0 and 100 Control Mode Type Access Range FlowDDE Flowbus Modbus Unsigned int RW 0 18 12 1 4 0x0024 37 The Controller mode is used to select different functions of the instrument The following modes...

Page 29: ...3 1 2 Identification Serial number Type Access Range FlowDDE Flowbus Modbus Unsigned char 20 R 92 113 3 0xF118 0xF11F 61721 61728 This parameter consists of a maximum 20 byte string with instrument se...

Page 30: ...0 1E 10 183 33 22 0xA1B0 0xA1B1 41393 41394 This is the capacity zero point offset for direct reading in sensor base units 3 1 4 Auto Zeroing To start the auto zero procedure two parameters should be...

Page 31: ...0 1E 10 254 114 1 0xF2F0 0xF2F1 62193 62194 Ti PIDTi Type Access Range FlowDDE Flowbus Modbus PDU Float RW 0 1E 10 168 114 22 0xF2B0 0xF2B1 62129 62130 Integration action in seconds of the PID control...

Page 32: ...irement After every power on reset the instrument will return to its default control mode The default control mode can be changed with the following parameter IOStatus Type Access Range FlowDDE Flowbu...

Page 33: ...Flowbus Modbus PDU Unsigned char RW 0 255 86 114 11 0xF258 62041 Bit 3 7 0 is used to disable the micro switch 0 micro switch disabled 1 micro switch enabled Procedure to enable the micro switch Read...

Page 34: ...table below Diameter mm Kv Normally closed p max bard 0 05 0 07 0 10 0 14 0 20 0 30 0 37 0 50 0 70 1 00 1 30 1 50 1 70 2 00 4 33 x 10 5 8 48 x 10 5 1 73 x 10 4 3 39 x 10 4 6 93 x 10 4 1 56 x 10 3 2 3...

Page 35: ...ntrol mode Pressing the switch 2x briefly with intervals of max 1 second in normal running operation mode will trigger the instrument to show its control mode For indication of the control mode number...

Page 36: ...dry meter with air or 2 N Valve blocked contaminated 3c clean valve Valve internal damage swollen seat in plunger 3d replace plunger assembly and adjust valve or return Incorrect type of gas is used a...

Page 37: ...e Contact your local Parker Sales office In the US contact the Parker factory or send an email describing the problem to ppfinfo parker com PARKER HANNIFIN CORPORATION INSTRUMENTATION GROUP PRECISION...