![Parker ValveMaster EX-M05 Series Operation Manual Download Page 4](http://html.mh-extra.com/html/parker/valvemaster-ex-m05-series/valvemaster-ex-m05-series_operation-manual_756278004.webp)
4
EX-M05 40983307 UK.indd RH 15.07.19
Test Unit
Series EX-M05
Operation Manual
Parker Hannifin Corporation
The test unit ValveMaster
®
is suitable for testing
and commissioning of all proportional and servo
proportional valves with onboard electronics.
For easy on-site service all necessary cables are
securely located inside of the rugged case. The
test unit provides all command signal sources and
measuring ports for concerted and time saving
control and diagnosis of the valves.
Features
• Control of valves incorporating integrated elec-
tronics and central plug acc. EN 175201-804
(6p.+PE)
• Built-in fuses and safety appliances
• Cable set included
• lockable rugged box
• DC valve output (24VDC/40W)
• Internal U/I-commands
• External command values pluggable
Technical data
Ordering code
Design
series
Test unit
Design
Lockable rugged box, polypropylene (break proof)
Supply voltage
[V] 85...260, 50...60 Hz
Power consumption
[VA] max. 160
Current consumption max.
[A] 1.3 at 230 V
Main input fuse
[A] 3.15 time lag
Required main supply fuse
[A] 16
Protection class
IP40
EMC
EN 61000-6-2
Valve central connection
Valve supply
[V] 24 (±5 %)
Command voltage
[V] 0...±10 (±1 %), 0...10, 0...±20 mA, 0...20 mA, 4...12...20 mA,
4...20 mA
Diagnostic output
0...±24 V / 0...±20 mA
Enable signal
[V] 7.5 (±10 %)
Measurement terminals
For multimeter with Ri min = 10 kOhm
Display
Display digits
4
Resolution
10 mV / 10 mA ; 1 digit
Main cord
Unit site
Cable inlet connector IEC320
Main site
CEE 7/7 plug
Cable length
[m] 2
Valve cords
A - control valves
B - DC valves
Unit site
Connector Amphenol SV70
DIN 40040
Connector M12x1 as per
IEC61076-2-101
Valve site
Female connector 6+PE
acc. EN175201-804
Female connector
acc. EN175301-803
Cable length
[m] 3
Ambient temperature
[°C] 0...40
Weight
[kg] 3.9
Dimensions
[mm] L 305 x B 270 x H 144
00
EX
M05
10