background image

To set up.

 

  

 

 

Before starting make sure that the end of the welding wire has been dressed and burrs and sharp edges 

 

removed to prevent internal scoring of the torch liner

 

Open the Pull-Mig Handle cover

 

Unscrew the tension knob

 

Open the pressure arm assembly 

 

Toggle feed the wire from the machine until it emerges from the liner.

 

Carefully and slowly feed the wire into the neck liner nipple. 

 

Close the pressure arm assembly.

 

Tighten the tension knob so it is fully wound down and locked into position     

 

Close the handle cover

The pressure arm is factory set to deliver the correct amount of side force to the drive roll. 
We do not recommend changing this setting.

Water-cooled Pull – Mig torches. 

If you have purchased a Water-Cooled variant, the water connections are industry standard and are marked blue (showing the cold 
water inlet) and red (showing the hot water outlet)

We recommend a good quality water coolant additive is added to the cooling fluid, this will enhance cooling through the torch body 
and will prolong torch hose life. It will also prevent frost damage to the torch internal components.

When first connecting a water-cooled variant, run the cooler before you weld to remove any trapped air pockets and remember to 
check the water levels in the cooler after this startup check. An average 8m torch will hold around 0.5 liters of coolant. After welding, 
we recommend that you run the water cooler for at least one minute to cool all the torch’s internal components. When removing a 
water-cooled torch from a recirculator and to prevent loss of coolant from the torch, use the red and blue stoppers that are supplied. 
We recommend draining the torch of coolant if it is not going to be used for any length of time.

You will require a water cooler ( recirculator ) with the following specification:

            Minimum water flow : 1.2 l/m

            Minimum inlet pressure :2.0 bar

            Minimum cooling capacity :1600W

            Maximum inlet pressure 5.0 bar

            Maximum water inlet temperature 50 degrees C

We strongly recommend that a flow switch be fitted to the return side of the recirculator and wired in series with the torch trigger. This 
flow switch will shut down the system and give torch protection should the water flow rate drop below 1.2 Litres per minute. (72 Litres 
per hour)

Water-Cooled neck assemblies

Water-Cooled Torch necks are supplied with a location pin. The purpose of this pin is to lock the neck in a positive position. The 
location pin registers in one of eight equi-spaced holes drilled in the neck seat.

If a different position is required to one of those eight pre-set positions, the pin can be removed but it must be removed with the Torch 
coolant drained from the torch. A gentle pull on the pin will remove it.

6

Summary of Contents for Suregrip Digi-Pull Mig Series

Page 1: ...Suregrip Digi Pull Mig Series OWNER S HANDBOOK...

Page 2: ...e switch is rated at 1A AC 250V AC Basic product data and conformity information Conformity information A sample of this product has been tested and found to be in conformity with the following standa...

Page 3: ...ons to get you going The PARKER TORCHOLOGY DIGI PULL MIG torch is designed to act as a power assist to the main wire drive system Wire is pushed from the main drive is passed across a motorized drive...

Page 4: ...e a slow start followed by fast forward Repeated pressing of the buttons provides an inch facility Holding the function buttons down causes the digital displays to advance quickly to aid searching You...

Page 5: ...rmal operation Parker team of specialist technical engineers is available to provide assistance to specifiers to enable them to select the most appropriate model and to give advice with the installati...

Page 6: ...the cooler after this startup check An average 8m torch will hold around 0 5 liters of coolant After welding we recommend that you run the water cooler for at least one minute to cool all the torch s...

Page 7: ...ecause during operation debris and dust is generally carried forward towards the neck end of the Liner Blowing from the opposite direction will push the debris into the Liner When a liner is due for r...

Page 8: ...Replacement liners are supplied cut to length and ground to 40 degrees They do not need adjustment and can be used straight from the package Refit the liner and nipple to the swan neck and re assemble...

Page 9: ...ll destroy the threads in the tip adaptor Drive Rolls Always make sure you have the correct drive roll for the type and size wire you are using and note that the drive roll threads are left hand and t...

Page 10: ...the claim we may ask one of our technical staff to discuss the problem with you to get a quick resolution Once the cause of the problem is established and at our discretion we will either repair or r...