May 2013

© Parker Hannifin Corporation

All products manufactured or distributed by Racor 
are subject to the following, and only the following, 
LIMITED EXPRESS WARRANTIES, and no others: 
For a period of one (1) year from and after the date of 
purchase of a new Racor product, Racor warrants and 
guarantees only to the original purchaser-user that 
such a product shall be free from defects of materials 
and workmanship in the manufacturing process. The 
warranty period for pumps and motors is specifically 
limited to ninety (90) days from date of purchase. A 
product claimed to be defective must be returned to 
the place of purchase. Racor, at its sole option, shall 
replace the defective product with a comparable new 
product or repair the defective product. This express 
warranty shall be inapplicable to any product not 
properly installed and properly used by the purchaser-
user or to any product damaged or impaired by 
external forces. 

THIS IS THE EXTENT OF WARRANTIES AVAILABLE 
ON THIS PRODUCT. RACOR SHALL HAVE NO 
LIABILITY WHATSOEVER FOR CONSEQUENTIAL 
DAMAGES FLOWING FROM THE USE OF ANY 

DEFECTIVE PRODUCT OR BY REASON OF THE 
FAILURE OF ANY PRODUCT. RACOR SPECIFICALLY 
DISAVOWS ALL OTHER WARRANTIES, EXPRESS 
OR IMPLIED INCLUDING, WITHOUT LIMITATION, 
ALL WARRANTIES OF FITNESS FOR A PARTICULAR 
PURPOSE (EXCEPT FOR THOSE WHICH APPLY 
TO PRODUCT OR PART THEREOF THAT IS 
USED OR BOUGHT FOR USE PRIMARILY FOR 
PERSONAL, FAMILY, OR HOUSEHOLD PURPOSES), 
WARRANTIES OF DESCRIPTION, WARRANTIES 
OF MERCHANTABILITY, TRADE USAGE OR 
WARRANTIES OR TRADE USAGE.

Warning

Failure or improper selection or improper use of the 
products and/or systems described herein or related 
items can cause death, personal injury and property 
damage. This document and other information 
from Parker Hannifin Corporation, its subsidiaries 
and authorized distributors provide product and/
or system options for further investigation by users 

having technical expertise. It is important that you 
analyze all aspects of your application and review 
the information concerning the product or system 
in the current product catalog. Due to the variety 
of operating conditions and applications for these 
products or systems, the user, through its own analysis 
and testing, is solely responsible for making the final 
selection of the products and systems and assuring 
that all performance, safety and warning requirements 
of the applications are met.   
The products described herein, including with 
limitation, product features, specifications, designs, 
availability and pricing, are subject to change by 
Parker Hannifin Corporation and its subsidiaries at 
any time without notice.

The following statement is required pursuant to 
proposition 65, applicable in the State of California: 
‘This product may contain a chemical known to the 
State of California to cause cancer or reproductive 
toxicity’.

Limited Warranties Statement

Fuel tanks above filter

head pressure should not

exceed maximum PSI of filter.

Fuel Tank

(Pressure Side Installation)

Install a shut-off valve when fuel 

tank is higher than filter

Fuel tank below filter

lift should not exceed 4 inHg.

Fuel Tank

(Ideal Vacuum 

Side Installation)

Fuel Tank

(Vacuum Side Installation)

Install a check valve 

(with light or no restriction) when 

tank is lower than filter to main 

prime.

Optional fuel transfer pump not to exceed 

maximum PSI or flow rate of filter.  

Not ideal - pumps emulsify water hindering 

filter performance.

Fuel transfer pump

(IDEAL vacuum side installation)

Engine

Maintain a service clearance below filter 

assembly of at least 2 in. (5.1 cm)

Valve 1

Valve 2

Valve 3

Optional Bypass Installation and Operation

(allows user to service filter without shutting down engine.)

            

Valves 

1 2 3

            Unit On-line 

Open 

Open     

Closed

            Unit Off-line 

Closed 

Closed 

Open

Installation Diagram

Summary of Contents for Racor 120R-RAC-01

Page 1: ...C 02 is marine UL Listed and USCG approved Instruction Part Number 10223 Rev C Marine Gasoline Series 120R RAC 01 and 120R RAC 02 Fuel Filter Water Separators 120R RAC 01 Specifications 120R RAC 01 120R RAC 02 Application Inboard Outboard No Yes Yes Yes Maximum Flow Rate 30 GPH 114 LPH 30 GPH 114 LPH Replacement Filter S3240 S3240TUL Center Threads M18 x 1 5 M18 x 1 5 Port Size 1 4 18 NPTF 1 4 18 ...

Page 2: ...fitting prior to installation into head For mounting flexibility there are two inlet ports and two outlet port Plated steel fittings are recommended Plug unused ports with provided steel NPT plugs do not use tapes on NPT threads Use quality fuel hose in maximum fuel line size applicable to reduce potential fuel flow restrictions Note USCG accepted hose recommended Thread fittings into appropriate ...

Page 3: ...3 Gasket Kit 4 S3240 120R RAC 01 10 micron Replacement Filter includes s 3 and 5 S3240UL 120R RAC 02 10 micron Replacement Filter includes s 3 and 5 5 RK 10012 Bowl O ring Kit 6 RK 10222 Clear Bowl Kit 01 model includes s 5 and 7 7 RK 30476 Self venting Drain Kit 8 RK10553 Metal Bowl Kit 02 model includes s 5 9 and 10 9 RK 20022 Probe Plug Kit 1 2 20 UNF 10 01SP 2S Drain Plug Kit 1 8 NPTF 1 2 3 4 ...

Page 4: ... subsidiaries and authorized distributors provide product and or system options for further investigation by users having technical expertise It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog Due to the variety of operating conditions and applications for these products or systems the user thr...