May 2013
© Parker Hannifin Corporation
All products manufactured or distributed by Racor
are subject to the following, and only the following,
LIMITED EXPRESS WARRANTIES, and no others:
For a period of one (1) year from and after the date of
purchase of a new Racor product, Racor warrants and
guarantees only to the original purchaser-user that
such a product shall be free from defects of materials
and workmanship in the manufacturing process. The
warranty period for pumps and motors is specifically
limited to ninety (90) days from date of purchase. A
product claimed to be defective must be returned to
the place of purchase. Racor, at its sole option, shall
replace the defective product with a comparable new
product or repair the defective product. This express
warranty shall be inapplicable to any product not
properly installed and properly used by the purchaser-
user or to any product damaged or impaired by
external forces.
THIS IS THE EXTENT OF WARRANTIES AVAILABLE
ON THIS PRODUCT. RACOR SHALL HAVE NO
LIABILITY WHATSOEVER FOR CONSEQUENTIAL
DAMAGES FLOWING FROM THE USE OF ANY
DEFECTIVE PRODUCT OR BY REASON OF THE
FAILURE OF ANY PRODUCT. RACOR SPECIFICALLY
DISAVOWS ALL OTHER WARRANTIES, EXPRESS
OR IMPLIED INCLUDING, WITHOUT LIMITATION,
ALL WARRANTIES OF FITNESS FOR A PARTICULAR
PURPOSE (EXCEPT FOR THOSE WHICH APPLY
TO PRODUCT OR PART THEREOF THAT IS
USED OR BOUGHT FOR USE PRIMARILY FOR
PERSONAL, FAMILY, OR HOUSEHOLD PURPOSES),
WARRANTIES OF DESCRIPTION, WARRANTIES
OF MERCHANTABILITY, TRADE USAGE OR
WARRANTIES OR TRADE USAGE.
Warning
Failure or improper selection or improper use of the
products and/or systems described herein or related
items can cause death, personal injury and property
damage. This document and other information
from Parker Hannifin Corporation, its subsidiaries
and authorized distributors provide product and/
or system options for further investigation by users
having technical expertise. It is important that you
analyze all aspects of your application and review
the information concerning the product or system
in the current product catalog. Due to the variety
of operating conditions and applications for these
products or systems, the user, through its own analysis
and testing, is solely responsible for making the final
selection of the products and systems and assuring
that all performance, safety and warning requirements
of the applications are met.
The products described herein, including with
limitation, product features, specifications, designs,
availability and pricing, are subject to change by
Parker Hannifin Corporation and its subsidiaries at
any time without notice.
The following statement is required pursuant to
proposition 65, applicable in the State of California:
‘This product may contain a chemical known to the
State of California to cause cancer or reproductive
toxicity’.
Limited Warranties Statement
Fuel tanks above filter
head pressure should not
exceed maximum PSI of filter.
Fuel Tank
(Pressure Side Installation)
Install a shut-off valve when fuel
tank is higher than filter
Fuel tank below filter
lift should not exceed 4 inHg.
Fuel Tank
(Ideal Vacuum
Side Installation)
Fuel Tank
(Vacuum Side Installation)
Install a check valve
(with light or no restriction) when
tank is lower than filter to main
prime.
Optional fuel transfer pump not to exceed
maximum PSI or flow rate of filter.
Not ideal - pumps emulsify water hindering
filter performance.
Fuel transfer pump
(IDEAL vacuum side installation)
Engine
Maintain a service clearance below filter
assembly of at least 2 in. (5.1 cm)
Valve 1
Valve 2
Valve 3
Optional Bypass Installation and Operation
(allows user to service filter without shutting down engine.)
Valves
1 2 3
Unit On-line
Open
Open
Closed
Unit Off-line
Closed
Closed
Open