PVSG User Guide
6
3. Inputs
The•PVSG•has•2•GPIO•inputs.•
•
•
Both•inputs•are•active•high•and•able•to•be•used•as•wake•up•(power•control)•inputs•to•activate•the•unit•
or•shut•it•down.
Damage to equipment!
•Do•not•connect•inputs•directly•to•unprotected•inductive•loads•
such•as•solenoids•or•relay•coils,•as•these•can•produce•high•voltage•spikes•that•may•
damage•the•CM0504.•If•an•inductive•load•must•be•connected•to•an•input,•use•a•protective•
diode•or•transorb.
3.1. Input capabilities
There•are•2•active•high•inputs•(INPUT1•and•INPUT2).•This•GPIO•Type•1•input••provides•a•fixed•input•
detection•threshold•with•fixed•pull•down•resistance.
The•primary•function•of•the•inputs•is•to•provide•a•wake•on•ignition•feature•as•a•digital•input.•The•‘Wake•
Up’•functionality•is•software•configurable.
A•secondary•function•is•to•interface•with•switch•sensors•in•an•application.
The•following•table•provides•specifications•for•the•inputs:
GPIO input Type 1 characteristics
Item
Min
Nom
Max
Unit
Input voltage range (non-operational)
0
32
V
Over voltage
36
V
Pull-up resistance
open
Input resistance w.r.t. ground
10.11
kΩ
Negative going threshold
3.375
3.67
Vt
Positive going threshold
3.65
3.931
V
Filtering - hardware time constant
28
us