isysNet Relay Output Module, Series A (PSSTR4M12A) 

E109P

4

Install the Relay Output Module

To Install the Relay Output Module, Proceed as Follows:

  1. Using a bladed screwdriver, rotate the keyswitch on the mounting 

base  clockwise  until  the  number  7  aligns  with  the  notch  in  the 
base.

  2. Position  the  module  vertically  above  the  mounting  base.  The 

module will bridge two bases.

  3. Push the module down until it engages the latching mechanism. You 

will hear a clicking sound when the module is properly engaged.

The locking mechanism will lock the module to the base.

Remove the Relay Output Module From the 
Mounting Base

To Remove the Module from the Mounting Base:

  1. Put a flat blade screwdriver into the slot of the orange latching 

mechanism.

  2. Push the screwdriver toward the I/O module to disengage the 

latch.  The module will lift up off the base.

  3. Pull the module off of the base.

0

1

2

3

0

1

2

3

MOD

NET

PSSTR4M12A

Form A

Isolated Relay Out

Module Will Bridge Two Bases

Summary of Contents for PSSTR4M12A

Page 1: ...hat all performance safety and warning requirements of the application are met The products described herein including without limitation product features specifications designs availability and prici...

Page 2: ...s Attentions help you Identify a Hazard Avoid a Hazard Recognize the Consequence SHOCK HAZARD Labels may be located on or inside the equipment to alert people that dangerous voltage may be present BUR...

Page 3: ...and Tap for M6 Screw Ground Lug Connection Latching Mechanism Mounting Base Keyswitch Set to position 7 for the PSSTR4M12A relay output modules Install the Mounting Base as Follows 1 Lay out the requ...

Page 4: ...odule down until it engages the latching mechanism You will hear a clicking sound when the module is properly engaged The locking mechanism will lock the module to the base Remove the Relay Output Mod...

Page 5: ...ur Module I O messages are sent to consumed and received from produced the I O module These messages are mapped into the processor s memory The I O relay output module consumes 1 byte of output data s...

Page 6: ...e that the PSSTR4M12A is now under the I O configuration Add Relay Output Module to RSLogix 5000 I O Configuration To add your relay output module to RSLogix 5000 I O configuration follow these steps...

Page 7: ...cation faulted device the device has detected a network access error and is in communication faulted state Device has received and accepted an Identity Communication Faulted Request long protocol mess...

Page 8: ...Test Nb Operating Thermal Shock 20 to 60 C 4 to 140 F Storage Temperature IEC 60068 2 1 Test Ab Un packaged Non operating Cold IEC 60068 2 2 Test Bb Un packaged Non operating Dry Heat 40 to 85 C 40 to...

Reviews: