Installation of the multi-axis system PSD1-M
60 (109)
192-011006N8 2019-07
09.10.19 09:27
*Display of error numbers by flash sequence
Green LED: Decimal
1 flash = 10; 2 flashes = 20; 3 flashes = 30; ...
Red LED: Single figure
1 flash = 1; 2 flahes = 2; 3 flashes = 3; ...
Adding both values results in the error number.
Display sequence:
•
Green LED = OFF, red LED on for 5 s
•
Green LED 1 … 9 flashes, depending on the error number.
•
Red LED 1 … 9 flashes, depending on the error number.
•
Green LED off and red LED off for 1 s).
This sequence repeats until the error is reset.
Meaning of the error numbers
11
Phase error
12
Voltage DC bus too low
13
Voltage DC bus too high
21
Temperature in the rectifier too high
22
Braking circuit overloaded
23
Temperature in the braking resistor too high
24
Short-circuit in the braking circuit
25
Rectifier overloaded
31
Voltage DC bus too high
32
Voltage offset DC bus too high
41
Overcurrent at digital output
51
None or wrong EEPROM - Data
Caution - Risk of electric shock!
High voltage supply may be present even with missing voltage supply (both
LEDs off)!
5.12.3.
S2: Modes switch (Power module)
Switch
position
Operating mode
0
standard
1
Increased performance by line choke mode
Warning!
Operating without line choke can destroy the device.
2 ... F
Not defined
Acceptance of the switch position when switching on 24 VDC Control
voltage.
5.12.4.
S3: Voltage switch (Power Module)
Switch
position
Supply-
voltage
Load Circuit
Umax
Turn-on
threshold [VDC]
Turn-off
threshold [VDC]
[VDC]
0
3AC400V
780
770
810
1
3AC110V
780
770
810
2
3AC230V
780
770
810
3
3AC380V
780
770
810
4
3AC480V
780
770
810
5
3AC230V
390
380
410
6
3AC110V
390
380
410
7
1AC230V*
390
380
410
8
1AC110V*
390
380
410
9 ..F
factory use