Parker PNC1050 User Manual Download Page 18

18 - Rev. E

PNC200 - PNC1200 USER GUIDE

9.   

Spare Parts List

Item 

#

Replacement parts

MODEL

PNC200
(DWG. # 

AD11511)

PNC250
(DWG. # 

AD11510)

PNC325
(DWG. # 

AD11509)

PNC400
(DWG. # 

AD11508)

PNC500
(DWG. # 

AD11507)

PNC700
(DWG. # 

AD11506)

PNC850
(DWG. # 

AD11505)

PNC1050

(DWG. # 

AD11504)

PNC1200

(DWG. # 

AD11503)

Refrigerant Compressor 

1A

230V/1PH/60Hz               

DP14231-1-C

DP14245-2-C

n/a

1B

230V/3PH/60Hz  

n/a

DP14245-3-C

DP16211-3

DP14341-3-C

DP14371-3-C

1C

460V/3PH/60Hz  

n/a

DP14245-4-C

DP16211-4

DP14341-4-C

DP14371-4-C

Fan motor

2A

230V/1PH/60Hz               

DP14231-2-M

DP14245-2-M

DP18184-2-M

DP14245-2-M

2B

460V/1PH/60Hz  

n/a

DP18105-4

DP18184

DP18105-4

3

Fan blade 

DP18182-B

DP18172-B

4

Refrigerant condenser

DP14231-CD

DP14245-CD

DP14295-C

DP14313-CD

DP14371-CD

5

Evaporator/separator/air-
air exchanger

XF0325-NCR-F

XF0500-

NCR-F

XF1000-NCR-F

6

Expansion valve 

DP34181-404

DP34182-404-1

DP34183-404

DP34185-404

7

Refrigerant filter   

DP28125

DP28135

8

Hot gas bypass valve

DP36062-4

DP36062-2

9

Fan #1 pressure switch  
(230v)

DP40080

DP40081

9A

**Fan #1 pressure switch  
(460v/575v)

DP40106

9B

Fan #2 pressure switch  
(230v)

n/a

DP40080

9C

**Fan #2 pressure switch  
(460v/575v)

n/a

DP40106

10

High refrigerant pressure 
switch

DP40133

11

Low refrigerant pressure 
switch

DP40026

12

Refrigerant gauge

DP42107

13

Timed drain assembly

TDS-025

14

Drain solenoid valve

TP8002-1

15

Valve strainer screen

KP5025-S

16

on/off rocker switch

EX0040-1

17

Red alarm light

EL1012

18

Amber power light

EL1011

19

Dewpoint indicator

398H354317

20

Compressor contactor

ES5035

21

Transformer

ET0250

21A

230/1 & 3 Fuse - Primary 
(Ctrl.Transformer)

EF0300-1-TD

21B

230/1 & 3 Fuse - Secondary 
(Ctrl.Transformer)

EF0300-1-TD

21C

460/3 Fuse - Primary 
(Ctrl.Transformer)

N/A

EF0150-G

21D

460/3 Fuse - Secondary 
(Ctrl.Transformer)

N/A

EF0300-1-TD

Cabinet panels

22

Front panel

DP0325-NC-

CAB-700-REV

DP0325-NC-CAB-800-REV

DP1000-NC-CAB-700

23

Back panel

DP0325-NC-CAB-500-REV

DP0500-NC-

CAB-500-REV

DP1000-NC-CAB-500

24

Left panel  

DP0325-NC-CAB-600-REV

DP-1000-NC-CAB-900

DP-1000-NC-CAB-800

25

Right panel

DP0325-NC-CAB-600-REV

DP1000-NC-CAB-600

26

Top panel

DP0325-NC-CAB-400-REV

DP1000-NC-CAB-400

** DP 40106 phased in during 2016. Units shipped early 2016 and older will need the following: Fan #1: DP40080 & Fan #2: DP40081. DP40106   
    is mounted directly on the top of electrical box, the others are not.

Summary of Contents for PNC1050

Page 1: ...User Guide Rev E Models PNC200 PNC1200 Parker Non Cycling Refrigerated Dryer Effective September 2015 Supercedes HY25 1890 M1 US June 2015...

Page 2: ...3 Controls Standard on all models 5 4 Start Up Procedures 6 4 1 When Operating Dryer 6 5 Routine Maintenance 7 6 Maintenance Schedule 8 6 1 Maintenance Procedures 8 7 Troubleshooting Service 9 7 1 Ref...

Page 3: ...n ambient temperature between 41 100 F 5 38 C and free from explosive and corrosive fumes Three 3 feet 92cm of space must be allowed between all open grills If the dryer is installed in a confined are...

Page 4: ...ns To be performed by a qualified person only Risk of serious injury or death Observe Lock out Tag Out Procedure Disconnect lock out and tag all power at source prior to attempting repairs or adjustme...

Page 5: ...Standard on all models Dryer ON OFF Switch Dryer POWER Light HIGH REFRIGERANT PRESSURE ALARM LOW REFRIGERANT PRESSURE ALARM DEWPOINT TEMPERATURE INDICATOR Adjustable time drain module mounted directly...

Page 6: ...s may be the result of shipping damage see section 1 0 4 Switch unit on ON OFF indicator will light 5 Do not pass air through the dryer until it stabilizes Typically 5 minutes 6 Once the dryer stabili...

Page 7: ...sis for dirt or debris that might accumulate Remove any debris immediately The strainer should be checked weekly Pre filtration per installation instructions Parker pre filter should be installed dire...

Page 8: ...ndensing coil fins air cooled units only Dryer Compressor oil level sight glass 250 to 1200 SCFM Filtration Depressurized dryer Replace pre and after filter elements Dryer Check for refrigerant leaks...

Page 9: ...loose connection open 3 Check electrical circuit Adjustments should only be made under the guidance of a certified refrigeration technician The controls interact with each other and although the effec...

Page 10: ...1 2 1 5 16 1 25 460 3 60 5 4 23 1 0 6 1 5 7 9 10 575 3 60 5 4 23 1 0 6 1 5 6 3 10 PNC700 230 3 60 15 7 98 1 3 1 2 23 2 35 460 3 60 7 1 38 1 1 5 1 2 11 0 15 575 3 60 7 1 38 1 1 5 1 2 8 8 15 PNC850 230...

Page 11: ...AOP040HNFI P040AO AAP040HNFI P040AA PNC250 AOP040HNFI P040AO AAP040HNFI P040AA PNC325 AOP040HNFI P040AO AAP040HNFI P040AA PNC400 AOP040HNFI P040AO AAP040HNFI P040AA PNC500 AOP04 5INFI P045AO AAP045INF...

Page 12: ...12 Rev E PNC200 PNC1200 USER GUIDE 11 Associated Drawings REF ADE11374 REV E...

Page 13: ...13 Rev E PNC200 PNC1200 USER GUIDE REF ADE11374 REV E...

Page 14: ...14 Rev E PNC200 PNC1200 USER GUIDE REF ADE11374 REV E...

Page 15: ...15 Rev E PNC200 PNC1200 USER GUIDE REF ADE11374 REV E...

Page 16: ...16 Rev E PNC200 PNC1200 USER GUIDE REF ADE11374 REV E...

Page 17: ...17 Rev E PNC200 PNC1200 USER GUIDE REF ADE11374 REV E...

Page 18: ...switch 230v n a DP40080 9C Fan 2 pressure switch 460v 575v n a DP40106 10 High refrigerant pressure switch DP40133 11 Low refrigerant pressure switch DP40026 12 Refrigerant gauge DP42107 13 Timed dra...

Page 19: ...xploded Views DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 200 EXPLODED ASSY AD11511 2 1 1 16...

Page 20: ...CALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 200 EXPLODED ASSY AD11511 2 2 1 16 2014 5 4 6 8 7 14 15 13 SEE...

Page 21: ...UIDE DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 250 EXPLODED ASSY AD11510 2 1 1 15 2014 26...

Page 22: ...ZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 250 EXPLODED ASSY AD11510 2 2 1 15 2014 20 21 3 2B 2A 11 10 9A 1C 1B 1A 14 15 13 5...

Page 23: ...UIDE DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 325 EXPLODED ASSY AD11509 2 1 1 15 2014 26...

Page 24: ...ZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 325 EXPLODED ASSY AD11509 2 2 1 15 2014 20 21 3 2B 2A 11 10 9A 1C 1B 1A 14 15 13 5...

Page 25: ...UIDE DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 400 EXPLODED ASSY AD11508 2 1 1 15 2014 26...

Page 26: ...TLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 400 EXPLODED ASSY AD11508 2 2 1 15 2014 20 21 3 2B 2A 11 10 9A 1C 1B 14 15 1...

Page 27: ...UIDE DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 500 EXPLODED ASSY AD11507 2 1 1 14 2014 26...

Page 28: ...TLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 500 EXPLODED ASSY AD11507 2 2 1 14 2014 13 4 8 7 6 14 15 3 2B 2A 21 20 9A 10...

Page 29: ...UIDE DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 700 EXPLODED ASSY AD11506 2 1 1 14 2014 12...

Page 30: ...TLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 700 EXPLODED ASSY AD11506 2 2 1 14 2014 8 7 6 5 13 4 SEE CONDENSING UNIT DET...

Page 31: ...UIDE DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 850 EXPLODED ASSY AD11505 2 1 1 14 2014 12...

Page 32: ...TLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 15 NON CYCLING 850 EXPLODED ASSY AD11505 2 2 1 14 2014 8 7 6 5 13 4 SEE CONDENSING UNIT DET...

Page 33: ...UIDE DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 16 NON CYCLING 1050 EXPLODED ASSY AD11504 2 1 1 14 2014 19...

Page 34: ...E SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 16 NON CYCLING 1050 EXPLODED ASSY AD11504 2 2 1 14 2014 5 13 6 10 7 8 4 2B 1C 9A 9B 21 20 SEE...

Page 35: ...UIDE DRAWN BY DATE SCALE UNITS TITLE SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 16 NON CYCLING 1200 EXPLODED ASSY AD11503 2 1 1 14 2014 19...

Page 36: ...E SIZE SHEET DRAWING NUMBER REVISION PARKER HANNIFIN FAF DIVISION LANCASTER NY 14086 USA INCHES OF B RJS 1 16 NON CYCLING 1200 EXPLODED ASSY AD11503 2 2 1 14 2014 5 13 6 10 7 8 4 2B 1C 9A 9B 21 20 SEE...

Page 37: ...dicate a response on a scale of 1 being the lowest to 5 being the highest Condition of Arrival Ease of Installation Ease of Start Up Product Quality Technical Assistance Clarity of Instruction Warrant...

Page 38: ...s Etten Leur Netherlands 31 76 508 5300 www parker com dhfns Hiross Airtek Essen Germany 49 2054 9340 www parker com hzfd Padova Italy 39 049 9712 111 www parker com hzfd Engine Filtration Water Purif...

Reviews: