Maintenance.

Used correctly, you can expect a long service life from a Parker 
plasma cutting torch.
There are a few common sense precautions you should
take note of when using and servicing your torch in order to
prolong its life.

Plasma consumables are rugged items, but they are made to
very tight tolerances, so if you do not use the correct tools to 
replace parts they are going to get damaged. We have 
provided a maintenance spanner within this instruction 
and guarantee pack and this should be sufficient 
for most needs. The spanner length is such, that by using 
hand tightening methods, you will not over tighten the parts.

If you are going to change parts, always turn off the 
power supply, it only takes a few seconds and it guarantees 
your safety.

Fault finding.

Cutting problems are normally caused by

       

Worn electrodes. If the Hafnium insert is recessed by 

       

more than 2mm it needs changing.

       

Worn cutting tip. If the hole is enlarged, and

     

or, a distorted shape, then it needs changing.

       

Dirty air. Plasma torches do not like wet or oily air. 

       

It causes unreliable cut quality and we always

       

recommend good quality air filters are fitted 

       

in your compressed air system. 

Plasma Warranty.

Every Parker Plasma cutting torch is manufactured to the highest 
standards and is warranted for 12 months from the date of sale 
to the end user. The warranty covers and is limited to a fault 
developing as a result of faulty workmanship or faulty materials. 

What is covered

Defective materials used in the manufacture of the product. 
Faulty workmanship in the manufacture of the product. 

What is not covered

Incorrect use or damage. 
Normal wear and tear to either the product or the consumables
supplied with the product. 
Faults arising from using non. Parker spare parts.
Direct or indirect costs of any form arising as a result of a 
suspected or actua defective product. 

How to make a claim. 

This warranty is limited to the original purchaser of the product.
If a fault is suspected the dealer, or ourselves. must be contacted 
and informed of the fault before the product is returned. 

You can contact us by

  

Mail:       [email protected]

 

Phone:  0086 531 88239823

 

Fax:        0086 531 88239398

How we will handle any claim

 

Parker’s sales office may ask you to return the product with a
copy of your proof of purchase, (If you are the end user) or 
a copy of proof of sale (If you are a distributer). 

Please note all returned torches should be complete with the 
consumables being used when the fault was detected, failure to 
do so the will invalidate the warranty.

Depending on the nature of the claim, we may ask one of our 
technical staff to discuss the problem with you to get a quick 
resolution to your concern. 

Once the cause of the problem is established, and at our 
discretion, we will either repair or replace the defective product 
free of charge.

If we believe the product failure is as a result of any reason other
than defective materials or manufacture, we will issue a written 
report to you detailing our findings. 

Maintenance, Fault Finding, and Warranty.

Copyright, all rights reserved

3

Summary of Contents for Plasma Cutting Series

Page 1: ...Plasma Cutting Series OWNER S HANDBOOK ...

Page 2: ...rch The switch is rated at 32V at 100 mA Requirements for connection of the torch these are covered above Plasma Cutting Torch Operating Manual Your plasma cutting torch Simple to follow instructions user tips A spares listing A maintenance spanner Basic product data and conformity information Conformity information A sample of this product has been tested and found to conform with the following s...

Page 3: ...y materials What is covered Defective materials used in the manufacture of the product Faulty workmanship in the manufacture of the product What is not covered Incorrect use or damage Normal wear and tear to either the product or the consumables supplied with the product Faults arising from using non Parker spare parts Direct or indirect costs of any form arising as a result of a suspected or actu...

Page 4: ...ike all modern tools they can be dangerous in untrained hands therefore we have assumed that you know how to use these products and appreciate the dangers of miss use These Plasma torches have the ability to inflict serious injuries if used by untrained personnel We strongly recommend that you are completely conversant with Plasma products and cutting techniques before you use this product If you ...

Page 5: ...direction Connecting the Torch If you have ordered direct to machine connections you will need to open the machine connection panels and wire the torch to your power source instructions Remember to turn off all power before connecting the torch Depending on your order your torch will come with either direct to machine connections or a euro connector Copyright all rights reserved 5 ...

Page 6: ...int or other coatings to ensure good electical contact Attach the work clamp as close as possible to the area being cut to reduce exposure to electromagnetic fields EMF Do not attach the work clamp to the portion that will fall away Copyright all rights reserved 6 ...

Page 7: ...s have different front end set ups to help improve ease of use Please refer to the wear parts configurator section in the wear parts manual for options or go to our web site www parkertorchology com cn After the torch trigger switch is released the gas will continue to flow for at least 60 seconds to cool the torch and consumables This helps to cool the torch and prolong the life of the consumable...

Page 8: ...ng Note Most torches have specialized front end set ups for the process Hold the torch so that the nozzle is within 1 16 in 1 5 mm from the workpiece before firing the torch Hold the torch at a 45 angle to the workpiece Pull the trigger to obtain a pilot arc Transfer the arc to the work piece Maintain an approximate 45 angle to the workpiece Feed into the gouge Printed on paper manufactured from s...

Page 9: ......

Page 10: ...an Export Processing Zone The East End Of Jing Shi Dong Road Jinan 250102 P R China Tel 86 531 88239823 Fax 86 531 88239398 Website www parkertorchology com Email info parkertorchology com MPP010 V 2019 06 ...

Reviews: