Maintenance.
Used correctly, you can expect a long service life from a Parker
plasma cutting torch.
There are a few common sense precautions you should
take note of when using and servicing your torch in order to
prolong its life.
Plasma consumables are rugged items, but they are made to
very tight tolerances, so if you do not use the correct tools to
replace parts they are going to get damaged. We have
provided a maintenance spanner within this instruction
and guarantee pack and this should be sufficient
for most needs. The spanner length is such, that by using
hand tightening methods, you will not over tighten the parts.
If you are going to change parts, always turn off the
power supply, it only takes a few seconds and it guarantees
your safety.
Fault finding.
Cutting problems are normally caused by
Worn electrodes. If the Hafnium insert is recessed by
more than 2mm it needs changing.
Worn cutting tip. If the hole is enlarged, and
or, a distorted shape, then it needs changing.
Dirty air. Plasma torches do not like wet or oily air.
It causes unreliable cut quality and we always
recommend good quality air filters are fitted
in your compressed air system.
Plasma Warranty.
Every Parker Plasma cutting torch is manufactured to the highest
standards and is warranted for 12 months from the date of sale
to the end user. The warranty covers and is limited to a fault
developing as a result of faulty workmanship or faulty materials.
What is covered
Defective materials used in the manufacture of the product.
Faulty workmanship in the manufacture of the product.
What is not covered
Incorrect use or damage.
Normal wear and tear to either the product or the consumables
supplied with the product.
Faults arising from using non. Parker spare parts.
Direct or indirect costs of any form arising as a result of a
suspected or actua defective product.
How to make a claim.
This warranty is limited to the original purchaser of the product.
If a fault is suspected the dealer, or ourselves. must be contacted
and informed of the fault before the product is returned.
You can contact us by
Mail: [email protected]
Phone: 0086 531 88239823
Fax: 0086 531 88239398
How we will handle any claim
Parker’s sales office may ask you to return the product with a
copy of your proof of purchase, (If you are the end user) or
a copy of proof of sale (If you are a distributer).
Please note all returned torches should be complete with the
consumables being used when the fault was detected, failure to
do so the will invalidate the warranty.
Depending on the nature of the claim, we may ask one of our
technical staff to discuss the problem with you to get a quick
resolution to your concern.
Once the cause of the problem is established, and at our
discretion, we will either repair or replace the defective product
free of charge.
If we believe the product failure is as a result of any reason other
than defective materials or manufacture, we will issue a written
report to you detailing our findings.
Maintenance, Fault Finding, and Warranty.