background image

© Parker Hannifin Corporation. All rights reserved.

ONE YEAR AIR QUALITY 

GUARANTEE

Your air quality has been guaranteed for 1 year and will be renewed at every annual filter element change.

Annual filter element changes ensure:

• Optimal performance is maintained

• Air quality continues to meet international standards

• Protection of downstream equipment, personnel and processes

• Low operational costs

• Increased productivity and profitability

• Peace of mind

PARKER HANNIFIN MANUFACTURING LIMITED

Gas Separation and Filtration Division EMEA
Dukesway, Team Valley Trading Est
Gateshead, Tyne and Wear
England NE11 0PZ

Tel: +44 (0) 191 402 9000

Fax: +44 (0) 191 482 6296

www.parker.com/gsfe

 

Summary of Contents for OIL-X Series

Page 1: ...OIL X COMPRESSED AIR FILTER Filters for Compressed Air USER GUIDE 17 118 6004 08 19 Rev A Maintenance Guide 171186001 Installation Setup Guide 171186002 Filtration User Guide EN P010 P055 WS A0 AA ACS ...

Page 2: ...ty Accessories Spare Parts Parker Worldwide Filter Weights and Dimensions System Depressurisation Filter Bowl Removal Removal of Element from Filter Bowl Automatic Drain Replacement Service Reminder Label System Start up Procedure Maintenance Intervals Insertion of Replacement Element into Filter Bowl Replacement of Filter Head O Ring Seal Reconnecting the Filter Bowl with Head Start Up Procedure ...

Page 3: ...03 OIL X Compressed Air Filter User Guide 2019 INSTALLATION RECOMMENDATIONS ...

Page 4: ...s a non serviceable item and should never be removed WS 1 3 4 2 AO AA 90o DIFFERENTIAL PRESSURE INDICATOR Fitted as standard to AA AO filters Hand tighten mounting screws and then torque to 2 5 Nm in sequence as shown 1 2 3 4 No DPI fitted to ACS or WS models Before pressurising the filter ensure that the head and bowl are correctly fitted and that the locking detail is properly aligned as shown i...

Page 5: ...se purification equipment should be installed as close to the application as possible Purification equipment should not be installed downstream of quick opening valves and should be protected from possible reverse flow or other shock conditions Purge all piping leading to the purification equipment before installation and all piping after the purification equipment is installed and before connecti...

Page 6: ...06 OIL X Compressed Air Filter User Guide 2019 START UP PROCEDURE ...

Page 7: ...ly open the inlet valve 01 to gradually pressurise the filter and wait 1 minute 02 before slowly opening the outlet valve 03 to re pressurise the downstream piping Note Do not open inlet or outlet valves rapidly or subject unit to excessive pressure differential as damage may occur 0 bar 7 bar 07 OIL X Compressed Air Filter User Guide 2019 01 03 WS AA AO 1 Minute 02 WS AA AO ...

Page 8: ...08 OIL X Compressed Air Filter User Guide 2019 PRODUCT MAINTENANCE ...

Page 9: ...uld always be placed downstream of a compressed air dryer to prolong adsorption filter element cartridge lifetime Compressor oil changes When compressor oil is changed the new lubricant burns off light ends which increases the oil vapour content for hours or even weeks afterwards This increase in oil vapour content is adsorbed by the adsorption filter element cartridge reducing the adsorption filt...

Page 10: ...rise the filter 03 using the drain Unscrew the filter bowl 01 02 and remove the used element 03 Note A strap wrench may be required for the removal of the 050 055 filter bowl 10 OIL X Compressed Air Filter User Guide 2019 Caution 0 bar 0 psi 01 02 03 Caution 0 bar 0 psi Safety Gloves Dispose Safely 01 02 ...

Page 11: ...L AUTOMATIC DRAIN REPLACEMENT Remove the element from the filter bowl Unscrew the automatic drain 01 and discard 02 Fit the new drain 03 and tighten 04 11 OIL X Compressed Air Filter User Guide 2019 2 5N m Dispose Safely 01 04 03 02 03 ...

Page 12: ...d with the new O ring provided Refit the filter bowl and head ensuring that the threads are fully engaged 01 and the locking details are aligned 02 Note To ensure that the bowl is fully engaged into the head the 010 030 bowl requires 360o of rotation until the thread stop 720o for the 035 045 bowl and 540o for the 050 055 bowl 12 OIL X Compressed Air Filter User Guide 2019 Ensure to lubricate the ...

Page 13: ...nd write on the date the element is to be replaced i e 12 months after element change Slowly open the inlet valve 01 to gradually pressurise the filter and wait 1 minute 02 before slowly opening the outlet valve 03 to re pressurise the downstream piping 13 OIL X Compressed Air Filter User Guide 2019 Do not use solvents or alcohol to clean the labels as this could cause damage 0 bar 0 psi 7 bar 100...

Page 14: ... Start up Procedure System De pressurisation Filter Bowl Removal Removal of Element from Filter Bowl Automatic Drain Replacement Insertion of Replacement Element into Filter Bowl Replacement of Filter Head O Ring Seal Reconnecting the Filter Bowl with Head Service Reminder Label System Start up Procedure Watch this guide via Parker Hannifin ...

Page 15: ...15 TECHNICAL SPECIFICATION ...

Page 16: ...TOR FLOW RATES CFP Correction Factor Minimum Inlet Pressure Water Separators MODEL PORT SIZE L S M3 MIN M3 HR CFM P010A P020D P045I P010C P035G P025E P055J P010B P025D P050I P015C P040H P030G 2 1 1 1 3 2 2 10 40 350 10 350 110 800 10 110 800 40 350 110 0 6 2 4 21 0 0 6 21 0 6 6 48 0 0 6 6 6 48 0 2 4 21 0 6 6 36 144 1260 36 1260 396 2880 36 396 2880 144 1260 396 21 85 742 21 742 233 1695 21 233 169...

Page 17: ... 8 233 911 466 1314 339 1314 699 P030 P050 P040 P055 P035 P055 P045 396 1548 792 2232 576 2232 1188 GRADE GRADE GRADE GRADE GRADE GRADE GRADE FILTER FLOW RATES CFP Correction Factor Minimum Inlet Pressure Coalescing and Dry Particulate Filters MODEL PORT SIZE L S M3 MIN REPLACEMENT ELEMENT KIT M3 HR CFM NO P010A P020C P010C P025D P010B P020D P015C P025E 1 10 30 10 60 10 30 20 60 0 6 1 8 0 6 3 6 0 ...

Page 18: ...1 35 6 28 0 79 2 54 1 08 6 46 2 64 10 80 7 09 10 91 20 31 7 09 17 32 9 37 17 32 7 09 10 91 9 37 17 32 10 91 20 31 6 06 9 13 17 48 6 06 15 08 7 95 15 08 6 06 9 13 7 95 15 08 9 13 17 48 2 99 4 72 7 56 2 99 6 46 3 5 6 46 2 99 4 72 3 5 6 46 4 72 7 56 1 97 2 76 4 72 1 97 3 94 1 97 3 94 1 97 2 76 1 97 3 94 2 76 4 72 2 56 4 53 7 20 2 56 6 18 3 31 6 18 2 56 4 53 3 31 6 18 4 53 7 20 1 5 1 5 1 57 1 5 1 5 1 ...

Page 19: ... 84 2 14 10 30 15 30 0 82 3 04 1 17 7 30 0 84 2 69 1 16 6 90 1 44 7 10 15 9 7 09 10 91 25 75 33 23 7 09 14 45 9 37 20 94 7 09 10 91 9 37 17 32 10 91 20 94 33 23 6 06 9 13 22 91 30 39 6 06 12 68 7 95 18 7 6 06 9 13 7 95 15 07 7 95 18 7 30 39 2 99 4 72 7 56 7 56 2 99 4 72 3 5 6 46 2 99 4 72 3 5 6 46 3 5 6 46 7 56 1 97 2 76 4 72 4 72 1 97 2 76 1 97 3 94 1 97 2 76 1 97 3 94 1 97 3 94 4 72 2 56 4 53 7 ...

Page 20: ...035 045 035 045 035 045 050 055 050 055 050 055 010 030 010 055 035 055 010 055 TRK1 2 MBK1 1 MBK1 2 TRK3 2 MBK3 1 MBK3 2 TRK2 2 MBK2 1 MBK2 2 TRK4 2 MBK4 1 MBK4 2 TRK5 2 MBK5 1 MBK5 2 DPI K PD15NO ZD90GL EM1 ACCESSORIES SPARE PARTS SERVICE KITS 20 OIL X Compressed Air Filter User Guide 2019 ...

Page 21: ...T ITALY Corsico MI Tel 39 02 45 19 21 parker italy parker com JP JAPAN Tokyo Tel 81 0 3 6408 3901 KR SOUTH KOREA Seoul Tel 82 2 559 0400 KZ KAZAKHSTAN Almaty Tel 7 7272 505 800 parker easteurope parker com LV LATVIA Riga Tel 371 6 745 2601 parker latvia parker com MX MEXICO Apodaca Tel 52 81 8156 6000 MY MALAYSIA Shah Alam Tel 60 3 7849 0800 NL The Netherlands Oldenzaal Tel 31 0 541 585 000 parker...

Page 22: ...erformance is maintained Air quality continues to meet international standards Protection of downstream equipment personnel and processes Low operational costs Increased productivity and profitability Peace of mind PARKER HANNIFIN MANUFACTURING LIMITED Gas Separation and Filtration Division EMEA Dukesway Team Valley Trading Est Gateshead Tyne and Wear England NE11 0PZ Tel 44 0 191 402 9000 Fax 44 ...

Reviews: