TECHNICAL DATA
Note:
AO / AA / WS grade filters for use up to 16 bar g (232 psi g) are supplied with a float drain [F] as standard.
For pressures between 16 and 20 bar g (232 and 290 psi g) a manual drain [M] must be used.
ACS grade filters are supplied with a manual drain [M] as standard.
17
OIL-X Compressed Air Filter - User Guide. ©2019.
FILTRATION
GRADE
FILTER MODELS
MIN
OPERATING
PRESSURE
MAX
OPERATING
PRESSURE
MIN
RECOMMENDED
OPERATING TEMP
MAX
RECOMMENDED
OPERATING TEMP
BAR G
PSI G
BAR G
PSI G
O
C
O
F
O
C
O
F
WS
with float drain
PX010 to 055
1.5
22
16
232
2
35
65
149
AO
with float drain
PX010 to 055
1.5
22
16
232
2
35
65
149
AO
with manual drain
PX010 to 055
1
15
20
290
2
35
80
176
AA
with float drain
PX010 to 055
1.5
22
16
232
2
35
65
149
AA
with manual drain
PX010 to 055
1
15
20
290
2
35
80
176
ACS
with manual drain
PX010 to 055
1
15
20
290
2
35
50
122