![Parker](http://html1.mh-extra.com/html/parker/n-series/n-series_user-manual_3778028008.webp)
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatics
M8
M
“N” Series Valves
Pilot Supply
Catalog 0600P-10/USA
Technical Information
Operating Pressure
Internal Pilot – Solenoid Valves
3/8" & 3/4" Body
• 20 to 140 PSIG (standard)
1-1/4" Body
• 25 to 140 PSIG (200 PSIG option available)
Operating Pressure Limitations
Air Pressure
Thru Valve
Remote Pilot Pressure (PSI)
3/8" Basic
3/4" Basic
1-1/4" Basic
25 PSI
30-250
30-250
30-250
50 PSI
50-250
50-250
50-250
75 PSI
70-250
75-250
70-250
100 PSI
95-250
95-250
90-250
150 PSI
140-250
145-250
130-250
200 PSI
175-250
185-250
175-250
250 PSI
215-250
230-250
205-250
Air Pressure
Thru Valve (PSI)
External Pilot Pressure Required (PSI)*
3/8" Basic
3/4" Basic
25 PSI
35-200
35-200
50 PSI
45-200
40-200
75 PSI
55-200
50-200
100 PSI
65-200
65-200
150 PSI
80-200
80-200
250 PSI
110-200
110-200
External Pilot supply should be used when the main valve needs to operate below the Minimum Operating
Pressure or at Vacuum. A Selector function can also be achieved (pressurizing the IN and EXHAUST ports)
with an External Pilot Supply. Refer to charts for required external pilot pressure.
1-1/4" Body
3/8" & 3/4" Body
3/8" & 3/4" Body
1-1/4" Body
Single Solenoid External Pilot
Normally Closed
Single Solenoid External Pilot
Normally Open
3/8" & 3/4" Body
3/8" & 3/4" Body
Remote Operated External Return
Normally Closed
Remote Operated External Return
Normally Open
Internal Pilot – Remote Pilot Valve
Vacuum up to 1" HG, less than a perfect vacuum.
* With 200 PSI option.
Do not exceed 140 PSI with standard pilots.
Solenoid Valves: External Supply
3/8" & 3/4" Basic