“N” Series

High Speed 
Inline Poppet Valves 
2 & 3-Way

Section M

www.parker.com/pneu/n

Basic Valve Functions .............................................. M2

“N” Series Basic Features ........................................ M3

Common Part Numbers ...................................... M4-M5

Model Number Index .......................................... M6-M7

Technical Information 

Pilot Supply .................................................... M8-M9 
Electrical Connections ....................................... M10 
Solenoid Characteristics .................................... M11 
Solenoid & Parts Lists ................................ M12-M14 
Coil Information .................................................. M15

Time Delay Modules ............................................... M16

Dimensions 

Single Solenoid .......................................... M17-M20 
Remote Operated ....................................... M21-M22

BOLD ITEMS ARE MOST POPULAR.

Summary of Contents for "N" Series

Page 1: ...m pneu n Basic Valve Functions M2 N Series Basic Features M3 Common Part Numbers M4 M5 Model Number Index M6 M7 Technical Information Pilot Supply M8 M9 Electrical Connections M10 Solenoid Characteris...

Page 2: ...t restrict the inlet Note For 2 Way Normally Closed Exhaust Port is Plugged Single Solenoid 3 Way 2 Position NO NP Normal position Pressure at inlet port marked IN open to cylinder Exhaust port is blo...

Page 3: ...3 8 Body 3 8 1 2 NPT 3 4 Body 1 2 3 4 1 NPT 1 1 4 Body 1 1 1 4 1 1 2 NPT BSPP G Threads Available Operating Pressure 30 to 250 PSI 0 to 1000 kPa Vacuum with External Pilot Features Continuous Duty Rat...

Page 4: ...tandard Service Junction Box w Light 120VAC 3 8 3 4 Body Size 3 Way Normally Open In Cyl Ports Exh Port N375 39 045 53 3 8 1 2 N375 49 045 53 1 2 1 2 N375 59 045 53 1 2 3 4 N375 69 045 53 3 4 1 N375 7...

Page 5: ...3 4 N374 61 091 3 4 1 N374 71 091 1 1 1 4 NPT Remote Pilot Port with Internal Pilot Return Single Remote Pilot Normally Closed 2 Way 2 Position 3 Way 2 Position Single Remote Pilot Normally Open 3 Wa...

Page 6: ...Cyl 1 1 2 Exhaust BSPP S 1 1 2 Inlet Cyl 1 1 2 Exhaust NPT 9 1 1 2 Inlet Cyl 1 1 2 Exhaust BSPP T Not available with Valve Function 325 Note BSPP is to the ISO 228 Standard and requires an R BSPT male...

Page 7: ...Options AC 60hz AC 50hz DC Standard Duty 49 24 5 6 53 120 110 5 6 8 9 Solenoid Type 0 Standard P Pilot Configuration 02 External Pilot Std Service 125 PSI 47 Internal Pilot Std Service 125 PSI Valve F...

Page 8: ...PSI 3 8 Basic 3 4 Basic 25 PSI 35 200 35 200 50 PSI 45 200 40 200 75 PSI 55 200 50 200 100 PSI 65 200 65 200 150 PSI 80 200 80 200 250 PSI 110 200 110 200 External Pilot supply should be used when th...

Page 9: ...n air reservoir is located close to the valve inlet as to not starve the valve of air pressure Basic Valve Size Inlet Port Size Exhaust Port Size Cv Inlet to Cylinder Cv Cylinder to Exhaust 3 8 3 Way...

Page 10: ...2 SOLENOID COIL 4 PIN MICRO TOP COVER 1 2 3 4 5 SOLENOID COIL 5 Pin Male Single Solenoid Encl Option N Wiring Option F 4 Pin Male Single Solenoid Encl Option J Wiring Option F 3 Pin Male Single Soleno...

Page 11: ...ontinuous Duty Pilot 3 8 3 4 Basic L Pilot Voltage Cycles Amps Inrush Amps Holding Resistance Ohms Watts Insulation Class 120 60VAC 29 18 122 12 B 110 50VAC 21 14 122 12 B 240 60VAC 18 12 610 12 B 24...

Page 12: ...0 H142 01 Seal 11 K41RB72011 O Ring STD Service H249 69 O Ring Continuous Duty Item No Part Number Description 12 K272 004 Plunger Guide 13 K152 003 Override Assembly 14 K183 047 Cover Gasket 16 K183...

Page 13: ...STD Service 7 K41RB72011 O Ring STD Service H249 69 O Ring Continuous Duty 10 K423 001 Top Seat K423 002 Top Seat Continuous Duty 11 K593 025 Coil 120V 60Hz 110V 50Hz K593 035 Coil 240V 60Hz 220V 50H...

Page 14: ...42 Plunger 8 K423 020 Top Seat 1 8 Orifice K423 022 Top Seat 3 16 Orifice 9 H134 36 Seal 10 H142 02 Seal 11 H142 15 Seal 12 K322 004 Junction Box Kit 13 K183 012 Gasket Coil leads are 19 long Parts in...

Page 15: ...9 24 K593097 51 48 K593254 53 115 K593108 58 230 K593111 Coils for L Pilot Operated Valves Coils for P Pilot Operated Valves Voltage Code Voltage Coil 60Hz 50Hz DC 19 Leads 72 Leads 40 12 K593007 41 4...

Page 16: ...e valve Function Time delay to be used with external pressure return valve only Time delay modules provide precise consistent delay of valve shift They eliminate the need for electrical timers and rel...

Page 17: ...uded in seal kit Key 3 8 Valve 3 4 Valve Description 1 1 2 Tap K053 075 Body N C 3 8 Tap K053 022 3 4 Tap K053 076 1 2 Tap K053 023 1 Tap K053 220 1A 3 4 Tap K053 077 Body N O 3 8 Tap K053 025 3 4 Tap...

Page 18: ...72121 K41RB72221 O Ring Parts included in seal kit Key 3 8 Valve 3 4 Valve Description 1 1 2 Tap K053 067 Body N C 3 8 Tap K053 019 3 4 Tap K053 069 1 2 Tap K053 157 1 Tap K053 221 1A 3 4 Tap K053 065...

Page 19: ...8 H178 17 Washer 9 H063 38 Stop Nut 10 K092 046 Bottom Cap N C 10A K103 061 Bottom Cap N O 11 K183 058 Gasket 12 K473 016 Spring 13 K012 003 Adapter 14 K41RB72143 O Ring Parts included in seal kit Nor...

Page 20: ...34 136 K 3 44 87 N 2 31 59 P 10 45 265 Q 4 56 116 Key 1 1 4 Valve Description 5 K493 016 Stem 6 K313 028 Lower Piston 7 H137 28 Seal 8 H178 17 Washer 9 H063 38 Stop Nut 10 K092 046 Bottom Cap N C 10A...

Page 21: ...3 018 K123 021 K123 024 Cover Parts included in seal kit Key 3 8 Valve 3 4 Valve 1 1 4 Valve Description 1 1 2 Tap K053 075 1 Tap K053 111 Body N O 3 8 Tap K053 022 3 4 Tap K053 076 1 1 4 Tap K053 112...

Page 22: ...002 K313 028 Lower Piston Assy 7 H135 19 H136 76 H137 28 Seal 8 H178 11 H178 13 H178 17 Washer 2 9 H063 26 H063 32 H063 38 Stop Nut 2 10 K092 020 K092 034 K092 046 Bottom Cap Assy N C 10A K103 035 K1...

Page 23: ...to change by Parker Hannifin Corporation and its subsidiaries at any time without notice Offer of Sale The items described in this document are hereby offered for sale by Parker Hannifin Corporation i...

Page 24: ...alve FRL Vacuum component or accessory Assuring that all user s performance endurance maintenance safety and warning requirements are met and that the application presents no health or safety hazards...

Page 25: ...mponents Air leakage Look and listen to see if there are any signs of visual damage to any of the components in the system Leakage is an indication of worn or damaged components Damaged or degraded co...

Page 26: ...which is utilized in the manufacture of the items sold hereunder even if such apparatus has been specially converted or adapted for such manufacture and notwithstanding any charges paid by Buyer Unle...