![Parker Lucifer P4CN40 C Series Bulletin Download Page 6](http://html1.mh-extra.com/html/parker/lucifer-p4cn40-c-series/lucifer-p4cn40-c-series_bulletin_4122793006.webp)
Bulletin 408134 R03 13.06.2016
Instructions de Montage, Mise en Service & Maintenance
EPP4 Pressure Regulator
Part Mo. 496540
6
Parker Hannifin Manufacturing Switzerland SA
Fluid Control Division Europe
CH-1227 Carouge-Genève
‘CALYS’ OPTION
Order No.:
496449 (Communication cable)
‘Calys'
is a software to set all parameters of the EPP4 Comfort.
The software is free of charge but you have to buy the specific
cable 496449 to establish the communication with the EPP4.
‘Calys’
has 3 levels of use, with 2 different passwords:
-
View
view only, no settings possible, no password
-
Setting
for basic settings and maintenance
-
Factory
only for authorized people, all settings
Parameters must be changed within the functional limits of the pressure regulators.
To use software
Calys,
you have to order specific communication cable ref 496449, then:
-
You can download free
Calys
software from www.parker.com/fcde/support
-
Install the software and use the Help File (pdf), it is the "?" on the page, up right corner. Select first your
language (E, F, D, I), the Help File will be in the same language.
-
Password needed to access "setting" level is "glage"
-
Connect the EPP4 to your computer (see below)
-
Re-set the EPP4 to your needs
Connection
Use the specific cable 496449 to connect the EPP4 to your computer:
RS-232
-
M12 connector on EPP B connector
-
Sub-D on computer
-
Select the Port Com in the TOOL menu
-
The “LED” bottom right corner becomes green if
communication is ok
USB
Install the driver from the CD delivered with the USB kit.
Read carefully the manual of the USB kit.
-
M12 connector on EPP B connector
-
Sub-D on USB adapter
-
USB adapter on computer
-
Select the Port Com in the TOOL menu