background image

www.parker.com/hfde

European Product Information Centre 

(24-hour)
Freephone: +00800 27 27 5374
(from AT, BE, CH, CZ, DE, EE, ES, FI, 

FR, IE, IT, PT, SE, SK, UK)

Parker Worldwide

AE – UAE

, Dubai 

Tel: +971 4 8875600 

[email protected]

AR – Argentina

, Buenos Aires 

Tel: +54 3327 44 4129

AT – Austria

, Wiener Neustadt 

Tel: +43 (0)2622 23501-0 

[email protected]

AT – Eastern Europe

Wiener Neustadt 

Tel: +43 (0)2622 23501 970 

[email protected]

AU – Australia

, Castle Hill 

Tel: +61 (0)2-9634 7777

AZ – Azerbaijan

, Baku 

Tel: +994 50 2233 458 

[email protected]

BE/LU – Belgium

, Nivelles 

Tel: +32 (0)67 280 900 

[email protected]

BR – Brazil

, Cachoeirinha RS 

Tel: +55 51 3470 9144

BY – Belarus

, Minsk 

Tel: +375 17 209 9399 

[email protected]

CA – Canada

, Milton, Ontario 

Tel: +1 905 693 3000

CH – Switzerland

, Etoy 

Tel: +41 (0) 21 821 02 30 

[email protected]

CN – China

, Shanghai 

Tel: +86 21 5031 2525

CZ – Czech Republic

, Klecany 

Tel: +420 284 083 111 

[email protected]

DE – Germany

, Kaarst 

Tel: +49 (0)2131 4016 0 

[email protected]

DK – Denmark

, Ballerup 

Tel: +45 43 56 04 00 

[email protected]

ES – Spain

, Madrid 

Tel: +34 902 33 00 01 

[email protected]

FI – Finland

, Vantaa 

Tel: +358 (0)20 753 2500 

[email protected]

FR – France

, Contamine s/Arve 

Tel: +33 (0)4 50 25 80 25 

[email protected]

GR – Greece

, Athens 

Tel: +30 210 933 6450 

[email protected]

HK – Hong Kong

 

Tel: +852 2428 8008

HU – Hungary

, Budapest 

Tel: +36 1 220 4155 

[email protected]

IE – Ireland

, Dublin 

Tel: +353 (0)1 466 6370 

[email protected]

IN – India

, Mumbai 

Tel: +91 22 6513 7081-85

IT – Italy

, Corsico (MI) 

Tel: +39 02 45 19 21 

[email protected]

JP – Japan

, Fujisawa 

Tel: +(81) 4 6635 3050

KR – South Korea

, Seoul 

Tel: +82 2 559 0400

KZ – Kazakhstan

, Almaty 

Tel: +7 7272 505 800 

[email protected]

LV – Latvia

, Riga 

Tel: +371 6 745 2601 

[email protected]

MX – Mexico

, Apodaca 

Tel: +52 81 8156 6000

MY – Malaysia

, Subang Jaya 

Tel: +60 3 5638 1476

NL – The Netherlands

Oldenzaal 

Tel: +31 (0)541 585 000 

[email protected]

NO – Norway

, Ski 

Tel: +47 64 91 10 00 

[email protected]

NZ – New Zealand

, Mt Wellington 

Tel: +64 9 574 1744

PL – Poland

, Warsaw 

Tel: +48 (0)22 573 24 00 

[email protected]

PT – Portugal

, Leca da Palmeira 

Tel: +351 22 999 7360 

[email protected]

RO – Romania

, Bucharest 

Tel: +40 21 252 1382 

[email protected]

RU – Russia

, Moscow 

Tel: +7 495 645-2156 

[email protected]

SE – Sweden

, Spånga 

Tel: +46 (0)8 59 79 50 00 

[email protected]

SG – Singapore

 

Tel: +65 6887 6300

SK – Slovakia

, Banská Bystrica 

Tel: +421 484 162 252 

[email protected]

SL – Slovenia

, Novo Mesto 

Tel: +386 7 337 6650 

[email protected]

TH – Thailand

, Bangkok 

Tel: +662 717 8140

TR – Turkey

, Istanbul 

Tel: +90 216 4997081 

[email protected]

TW – Taiwan

, Taipei 

Tel: +886 2 2298 8987

UA – Ukraine

, Kiev 

Tel +380 44 494 2731 

[email protected]

UK – United Kingdom

Warwick 

Tel: +44 (0)1926 317 878 

[email protected]

US – USA

, Cleveland 

Tel: +1 216 896 3000

VE – Venezuela

, Caracas 

Tel: +58 212 238 5422

ZA – South Africa

Kempton Park 

Tel: +27 (0)11 961 0700 

[email protected]

© 2015 Parker Hannifin Corporation. 

All rights reserved.

DD0000002_IPDR_EN_Rev 1

Summary of Contents for icountPDR

Page 1: ...icountPDR icountPDR User Manual DD0000002_IPDR_EN_Rev 1 2015 Parker Hannifin Corporation www parker com hfde GB...

Page 2: ...draulic connection 11 Flow control 12 System 20 sensor connection 14 Electrical connections 15 Variable current output settings 20 Variable voltage output settings 21 CAN bus output option 21 Moisture...

Page 3: ...ation users are NOT permitted to open the unit under any circumstances Doing so will invalidate the unit s calibration and it would NOT be suitable for calibrated use RH limitations Extended exposure...

Page 4: ...GB 4 Parker Hannifin icountPDR EC Declaration of Conformity...

Page 5: ...equentially through a month reverting to 001 at the beginning of each month 3 D O M Date of manufacture 4 Manufactured Country of manufacture United Kingdom 5 Exclamation mark icon Refer to product ma...

Page 6: ...asurements and that is the Measurement Period This can be set from 5 seconds to 180 seconds The longer the Measurement Period the more contaminant is measured averaging out any spikes seen on a smalle...

Page 7: ...m and High contamination levels A low cost solution to prolonging fluid life and reducing machine downtime Self diagnostic software Mineral fluid compatible construction Fully PC PLC integration techn...

Page 8: ...USGPM Size 1 24 to 100 l min 6 26 USGPM Size 2 170 to 380 l min 45 100 USGPM Ambient storage temperature 40 C to 80 C 40 F to 176 F Environment operating temperature 30 C to 60 C 22 F to 140 F Fluid o...

Page 9: ...andards ISO Particle limits 19 18 15 Measurement period 60 seconds Reporting interval 30 seconds Power on mode AUTO Auto start delay 5 seconds Date format dd mm yy Default if options fitted Relay hyst...

Page 10: ...unting locations two each side to suit M8 5 16 fixings supplied Communication and Supply cable M12 12 pin Ultra Lock IP69 Rated female connector Supply Limit Cable 5m 16ft 4in Product identification l...

Page 11: ...supplied with two 06L EO 24 cone end hydraulic connections for use with a 6mm pipe For hydraulic connection ensure that the hydraulic pipe connection fitting is compatible with the size 06L EO 24 cone...

Page 12: ...ns i e 40 140 ml min or where pipe diameters do not allow the icountPDR to be installed directly The flow control device fits onto the downstream outlet side of the icountPDR A 06L G1 8A female adapte...

Page 13: ...he inlet and outlet sides of the mounting block The differential pressure valve automatically compensates for pressure and viscosity changes while maintaining its flow setting even as the workload cha...

Page 14: ...ring System 20 sensors See Inline Sensor Monitors Parker Hannifin Brochure CM013GB1 for more information on System 20 sensors IMPORTANT NOTE P1 and P2 of the System 20 sensors MUST be connected to the...

Page 15: ...slot are correctly aligned to avoid damaging the pins and push home firmly to connect To disconnect pull the Ultra Lock s metal collar back to release the cable lock and pull the cable boot out squar...

Page 16: ...re Sensor CAN Ground 8 Red Product Supply 9 40Vdc Product Supply 9 40Vdc Product Supply 9 40Vdc Product Supply 9 40Vdc 9 Black Product Supply 0Vdc Product Supply 0Vdc Product Supply 0Vdc Product Suppl...

Page 17: ...nnel A 0 5V 0 3V output Green Channel B 0 5V 0 3V output Yellow 0 5V 0 3V supply 12 24V Brown Product supply 0Vdc Black Product supply 9 40Vdc Red Optional switch box ms B A C This example shows the s...

Page 18: ...l A 4 20mA output Green Channel B 4 20mA output Yellow 4 20mA supply 12 20Vdc Brown Product supply 0Vdc Black Product supply 9 40Vdc Red Optional switch box ms B A C This example shows the switch posi...

Page 19: ...B CAN bus SAE J1939 connections CAN Ground Blue CAN Hi Green CAN Low White Product supply 0Vdc Black CAN Hi CAN Low CAN Ground Product supply 9 40Vdc Red PSU icountPDR Comms and Supply CAN controller...

Page 20: ...9 5 20 ISO 17 18 19 20 21 22 Over range ERROR The actual calculation is as follows ISO code output in mA 4 x 2 e g 11 5mA 4 x 2 7 5 x 2 ISO 15 Saturation i e above ISO code 22 ISO v output mA ISO code...

Page 21: ...Voltage output NAS Err 00 0 1 2 3 4 5 6 7 8 9 10 11 12 Err 0 5Vdc 0 4 0 6 0 9 1 2 1 5 1 8 2 1 2 4 2 7 3 0 3 3 3 6 3 9 4 2 4 5 4 6 0 3Vdc 0 2 N S 0 3 0 5 0 7 0 9 1 1 1 3 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2...

Page 22: ...DIGITAL DISPLAY UNITS AVAILABLE Part number Description DDU1001 Process indicator 22 55Vdc DDU1002 Process indicator 90 264Vdc Digital Display Units e g Parker Hannifin DDU1002 Output channel C White...

Page 23: ...rn Please contact Parker Hannifin Sales for a range of DDUs Digital Display Units Output channel C White Output channel A Green Output channel B Yellow Product supply 9 40Vdc Red Product supply 0Vdc B...

Page 24: ...to be connected to a 9 way D type connector not supplied as standard For the connector pin termination and wire colour refer to the Communication and Supply cable connector section of this manual page...

Page 25: ...ay also use Microsoft Windows HyperTerminal program but note that this program is not currently supplied with the Windows Vista operating system icountPD Setup Utility software PC Installation The ico...

Page 26: ...nfiguration Relay Options and Alarm Limits Step 2 Set the values for Detector ID and Date Format The remaining detector information is preset by Parker Hannifin and cannot be changed Step 4 Set the Vo...

Page 27: ...Software Parker Hannifin icountPDR 27 GB Step 5 Setup values are verified as valid in Results Click Start to start verification and Stop to stop...

Page 28: ...ganisation s IT department if the program is not present Please note that HyperTerminal is not supplied with Windows Vista but the Parker Terminal utility can be used with this operating system The st...

Page 29: ...settings as in the standard communications settings table on the previous page Step 6 Once the icountPDR is connected to power the product identification is displayed This screen shown is only for exa...

Page 30: ...e only and can be accessed via a password system Should an unauthorized person attempt to access these commands the icountPDR returns the error code for Invalid Command A list of error codes is given...

Page 31: ...er Fault number displayed RJE Read J1939 Status ON or OFF displayed RLR Read the Last contamination Result Last contamination result displayed RLT Read contamination Limit Threshold Contamination limi...

Page 32: ...e full description of the error code i e Error 40 Expected On or Off Error Verbose OFF displays just the error code i e Error 40 SJE Set J1939 Status SJE On Off can only set On SLT Set contamination L...

Page 33: ...ff SWM Set Warning limit relay for Moisture 1 2 SWM on SWM off 1 Command requires a Moisture sensor to be fitted to the icountPDR 2 Command requires a Limit Relay to be fitted to the icountPDR 3 Comma...

Page 34: ...e error codes are given in the following table Code Message Error 0 No error Error 1 Unknown command Error 2 Characters after command ignored Error 3 Command ignored unit is busy Error 5 Unexpected ch...

Page 35: ...GB Reference Contamination Standards See the Parker Guide to Contamination Standards DD0000015 available on your CD This publication makes available industry recognized cleanliness specifications for...

Page 36: ...nalyse has a relative viscosity to 60 cSt to generate the optimum flow rate 60ml min a differential pressure of 0 5bar is required If the fluid you wish to analyse has a relative viscosity of 400 cSt...

Page 37: ...restry NOTE It is advisable to make a note of any changes you make for future reference To SET the above states launch HyperTerminal and with the unit reporting enter SJP followed by the setting optio...

Page 38: ...aling offset not used Unit not used SPNL SPN low byte Under normal operation the product is restricted to SPN2551 proprietary group B This register is not acted on until the SPNH register is loaded SP...

Page 39: ...countPDR 39 GB Example IQAN screen NOTE The CanBus termination resistor is built onto the PCB so an additional termination resistor should not be required when connecting to a Management Information S...

Page 40: ...ay Limit Relay Comms Moisture sensor Cable connector kit IPDR 1 Mineral 2 MTD 1 None 1 No 2 RS232 4 20mA 1 No 40 M12 12 pin plug connector 3 Aviation fuel 4 channels 3 RS232 0 5V 2 Yes 10 Deutsch 12 p...

Page 41: ...Reference Parker Hannifin icountPDR 41 GB...

Page 42: ...Ireland Dublin Tel 353 0 1 466 6370 parker ireland parker com IN India Mumbai Tel 91 22 6513 7081 85 IT Italy Corsico MI Tel 39 02 45 19 21 parker italy parker com JP Japan Fujisawa Tel 81 4 6635 305...

Reviews: