5
HX SERIES USER GUIDE
3.
Intended Use
The information on the product label must be observed. Non-observance of the data given there is regarded as
improper use. The filters are suitable for filtering compressed air and other non-flammable inert gases, such as
nitrogen.
3.1
Impermissible Applications
The filtration of liquids is not permitted. HX-Series filters must
NEVER
be used for filtration of explosive,
flammable, or noxious gases (including natural gas). Modifications to HX-Series pressure vessels and
elements will endanger operational safety and may cause damage or personal injury and are not permitted.
4.
Filter Installation and Maintenance Personnel
These operating instructions are intended for specialists charged with the installation, operation, and maintenance
of compressed air filters. Such persons must be trained in and have basic working knowledge of handling pressure
devises.
5.
Safety Instructions
5.1
Hazard due to a sudden release of pressure!
Never remove any parts of the filter, or manipulate the filter in any way, as long as the filter is pressurized. A
sudden release of pressure may cause serious injuries. BE SURE TO DEPRESSURIZE THE FILTER before
carrying out any work on the filter. Verify that the housing has been depressurized using a gauge known to be
in good working order.
6C HX C K
Element Type
Series
Bowl Size
Kit
4C
HX
A
K = Kit
6C
B
8C
BH
10C
C
7CP
D
XF
E
WS
F
3P
G
A
H
J
2.2
HX Series Replacement Elements
Examples:
6CHXAK, WSHXBHK, XFHXJK, 6CHXGK