Appendix A – Specifications
59
Environmental Specifications
GV-L3n;
GV-U3n/U6n/U12n;
GV-H20n (with
< 25W regen);
GV-H20n (with
GV-H40n
<100W regen)
Operating Temperature:
Still Air:
45
°
C (113
°
F)
35
°
C (95
°
F)
Moving air:
50
°
C (122
°
F)
40
°
C (104
°
F)
Minimum:
0
°
C (32
°
F)
0
°
C (32
°
F)
Storage Temperature:
-40
°
C – 85
°
C (-40
°
F – 185
°
F)
Humidity:
0 – 95%, non-condensing
Shock:
15g, 11msec half sine
Vibration:
10 – 2000 Hz at 2g
Standards
UL, cUL
508C
CE for LVD
72/23/EEC
BS EN61010-1:1993/A2:1995 (ie includes 1995 amendment AMD 8961)
Safety requirements for electrical equipment for measurement, control,
and laboratory use
Part 1. General requirements
CE for EMC
89/336/EEC
BS EN61800-3: 1997
Adjustable speed electric power drive systems
Part 3. EMC product standard including
specific test methods.
IEC 61800-3: 1996
Adjustable speed electric power drive systems
Part 3. EMC product standard including
specific test methods.
Interface/Communication
Connector:
Drive connector:
9 pin D-subminiature plug.
Mating connector:
9 pin D-subminiature receptacle
RS-232:
RS-485*:
Rx, Tx, Gnd
4-wire plus ground (Rx+, Rx-, Tx+, Tx-, Gnd)
9600 baud
9600 baud
8 data bits
8 data bits
1 stop bit
1 stop bit
no parity
no parity
full duplex
full duplex
*twisted pair cabling recommended (e.g. Belden 9842)
Weight
Weight
Drive
pounds (kg)
GV-L3n:
4.2 (1.9)
GV-U3n:
4.2 (1.9)
GV-U6n:
4.9 (2.2)
GV-U12n:
4.9 (2.2)
GV-H20n:
8.9 (4.0)
GV-H40n:
15.8 (7.2)