WARNINGS FOR INSTALLER AND USER
All the operations indicated on these warnings must be carried out by qualified staff according to the
regulations in force.
This category I 3B/P appliance can only run on
Butane/Propane
and does not need any adjustment.
ATTENTION:
don’t move the appliance during use or when it is still warm.
Change deteriorated gas pipes and replace them before expiry date imprinted on
the pipe.
Pipes must not be dented in any parts and must be installed in such a way that
they don’t have to be placed under any strain.
They must not come into contact with any hot part.
Nevertheless after connection check that the burner flame is stable and properly
ventilated.
Air regulation band:
if not already fitted, fit it as in the photo, observing the
dimension X=5mm, which is to be considered indicative and can be modified in
relation to the appearance of the flame.
THE GAS BOTTLE SHALL RUN ON A MAXIMUM OF 10 KG. OF BUTANE
The label is on the front of the appliance.
WARNINGS FOR INSTALLER
INSTALLATION OF THE APPLIANCE
The appliance can be placed on a surface with the following specifications:
- the support shall have a temperature resistance of at least 80°C;
- ONLY FOR
OUTDOOR USE
- Installation must be carried out following the installation regulations in force
CONNECTION TO GAS SUPPLY
The appliance operates with butan/propan gas and must be connected using flexible pipes to hose holder.
The flexible pipe must be in accordance with the particular laws in force.
The rubber flexible pipe must be in accordance with the standards in force and fixed to hose holder with
clamp. Pressure regulator of the gas bottle must be in accordance with the regulations in force (
DO NOT
USE HIGH PRESSURE REGULATORS!
)
The installation of this appliance must be carried out by qualified person in accordance with the
requirements of the gas safety regulations, the local building regulations and the by-laws of the local
undertakings.
It should also be in accordance with any relevant requirements of the local gas region of LPG supplier, the
local authority and the relevant recommendations of the standards (latest edition) concerned.
All gas cylinder connection and replacement operations shall be performed by skilled staff in compliance
with the following observations:
- Before connecting the cylinder carefully close the burner’s taps and those of the cylinder to be replaced.
Unscrew the pressure adjuster of the cylinder by unscrewing the nut in clockwise direction.
- Remove protection hood from the cylinder to be connected and unscrew the closing nut (left threaded).
The closing tap must not be damaged.
- After checking if the gasket is in place on the cylinder tap and that no gasket is stuck to the pressure
adjuster, manually screw the pressure adjuster by turning the nut in anticlockwise direction.
- Do not turn the adjuster. Make sure that the pipe is not being pulled.