5
Parker Hannifin
Pump & Motor Division Europe
Trollhättan, Sweden
Service/Spare Parts Manual
Series F10
MSG30-5524-M1/UK
Specifications
1) Intermittent: max 6 seconds in any one minute.
Frame size F10 -030 -037 -056 -080 -090 -107 -125
Displacement
[cm
3
/rev] 30.0
37.0
54.4
78.6
93.0 104.0 125.0
Operating pressure
3)
max intermittent
1)
[bar]
350
350
350
350
350
350
350
max continuous [bar]
300
300
300
300
300
300
300
Motor operating speed
3)
[rpm]
max intermittent
1)
5400 4900 4200 3900 3800 3500 3100
max continuous 4900 4400 3800 3500 3400 3200 2800
min continuous
50
50
50
50
50
50
50
Max pump selfpriming speed
L or R function; max [rpm] 3100 3000 2300 2150 2000 1950 2000
Motor input flow
max intermittent
1)
[l/min]
162
196
228
307
353
364
387
max continuous [l/min]
147
176
207
275
316
333
350
Drain temperature
, max [°C]
115
115
115
115
115
115
115
min [°C]
-40
-40
-40
-40
-40
-40
-40
Theoretical torque at 100 bar
[Nm]
47.6
58.7
86.3 124.7 174.8 198.4
241
Mass moment of inertia
(x10
-3
) [kg m
2
]
1.7
1.7
2.9
5.0
8.4
8.4
11.2
Weight
[kg] 11.5
11.5
15.7
18.6
25.7
25.7
33.0