Parker Compax3F Fluid Installation Manual Download Page 9

 

 

Parker EME 

Safety instructions 

 

192-121100 N8 September 2014

 

2.5 

Safety instructions 

General hazards

In this chapter you can read about: 

 ................................................................................................................ 9 

Safety-conscious working .................................................................................................. 9 
Special safety instructions ....
............................................................................................. 9 

 

 

2.5.1. 

General hazards 

General Hazards on Non-Compliance with the Safety Instructions 
The device described in this manual is designed in accordance with the latest 
technology and is safe in operation. Nevertheless, the device can entail certain 
hazards if used improperly or for purposes other than those explicitly intended. 
Electronic, moving and rotating components can 

 

constitute a hazard for body and life of the user, and 

 

cause material damage 

 

Designated use 

The device is designed for operation in electric power drive systems (VDE0160). 
Motion sequences can be automated with this device. Several motion sequences 
can be can combined by interconnecting several of these devices. Mutual 
interlocking functions must be incorporated for this purpose. 

 

2.5.2. 

Safety-conscious working 

This device may be operated only by qualified personnel. 
Qualified personnel in the sense of these operating instructions consists of: 

 

Persons who, by virtue to their training, experience and instruction, and their 
knowledge of pertinent norms, specifications, accident prevention regulations and 
operational relationships, have been authorized by the officer responsible for the 
safety of the system to perform the required task and in the process are capable of 
recognizing potential hazards and avoiding them (definition of technical personnel 
according to VDE105 or IEC364), 

 

Persons who have a knowledge of first-aid techniques and the local emergency 
rescue services. 

 

persons who have read and will observe the safety instructions. 

 

Those who have read and observe the manual or help (or the sections pertinent to 
the work to be carried out). 

This applies to all work relating to setting up, commissioning, configuring, 
programming, modifying the conditions of utilization and operating modes, and to 
maintenance work. 
This manual and the help information must be available close to the device during 
the performance of all tasks. 

 

2.5.3. 

Special safety instructions 

 

Check the correct association of the device and its documentation. 

 

Never detach electrical connections while voltage is applied to them. 

 

Safety devices must be provided to prevent human contact with moving or rotating 
parts. 

 

Make sure that the device is operated only when it is in perfect condition. 

 

Implement and activate the stipulated safety functions and devices. 

 

Operate the device only with the housing closed. 

 

Make sure that all devices are sufficiently fixed. 

 

Summary of Contents for Compax3F Fluid

Page 1: ...he data correspond to the current status at the time of printing Compax3 Fluid Installation Manual Hydraulics Controller Paper version Release as from R09 63 C3Manager Compax3F Unterlagen Software use...

Page 2: ...656 Offenburg Germany Tel 49 0781 509 0 Fax 49 0781 509 98176 Internet www parker com eme http www parker com eme E mail sales automation parker com mailto EM Motion parker com Parker Hannifin GmbH Si...

Page 3: ...ndently from the Parker Integrated Engineering Tool After the installation of the ServoManager you can copy the desired Online help system with the C3 ServoManager Help Installer you can select the C3...

Page 4: ...rator authorization on the target computer Note Several applications running in parallel reduce the performance and operability Especially customer applications exchanging standard system components d...

Page 5: ...utilization for CE conform operation 10 2 8 EC declaration of conformity Compax3F 11 3 Compax3F device description 12 3 1 State of delivery 12 3 2 Plug and connector assignment Compax3 Fluid 12 3 2 1...

Page 6: ...id This manual is valid for the following devices C3F001D2 F12 supplement 2 2 Scope of delivery The following items are furnished with the device Manuals Installation manual German English French Comp...

Page 7: ...ler 001 10V and 0 20mA outputs 16 Bit D2 24VDC device 3 Unique number of the particular device 4 Supply voltage 24 VDC 5 Date of factory test 6 Designation of the feedback system F12 Feedback Module 7...

Page 8: ...ntains materials that fall under the special disposal regulation from 1996 which corresponds to the EC directory 91 689 EEC for dangerous disposal material We recommend to dispose of the respective ma...

Page 9: ...e of pertinent norms specifications accident prevention regulations and operational relationships have been authorized by the officer responsible for the safety of the system to perform the required t...

Page 10: ...d Shielding connection of the valve cables The cable must be fully screened and connected to the Compax3 housing Use the cable clamps shield connecting terminals furnished with the device The shield o...

Page 11: ...Parker EME EC declaration of conformity Compax3F 192 121100 N8 September 2014 11 2 8 EC declaration of conformity Compax3F...

Page 12: ...ignment 13 Plug and connector assignment complete 14 Analog Input plug X1 15 Analog Output plug X2 16 Voltage supply plug X3 17 RS232 RS485 interface plug X10 17 Analog Encoder plug X11 18 Digital inp...

Page 13: ...192 121100 N8 September 2014 13 3 2 2 Plug and connector assignment X1 Analog Inputs X2 Analog Outputs X3 24 VDC power supply X10 RS232 RS485 X11 2 Feedback Type X12 Inputs Outputs X13 1 Feedback Typ...

Page 14: ...O8 I8 Input24VDC O9 I9 O10 I10 O11 I11 InputGND X22 Input Output option M12 M10 HEDA HEDA motionbus option M11 M10 I Os X20 6 Lx X20 7 res X20 8 res X20 HEDA in X20 1 Rx X20 2 Rx X20 3 Lx X20 4 res X2...

Page 15: ...IN3 Signal Sensor 3 16 IN3 Signal Sensor 3 17 IN4 10V Input 4 18 IN4 10V Input 4 19 IN5 10V Input 5 20 IN5 10V Input 5 Requirement Connection cable Use shielded cables Shield connection of the cables...

Page 16: ...Voltage 10V 1000 Current 4 20mA 600 Current 100mA 100 All outputs are short circuit proof Requirement Connection cable Use shielded cables Shield connection of the cables The cable must be fully scree...

Page 17: ...2 7 RS232 RS485 interface plug X10 Interface selectable by contact functions assignment of X10 1 X10 1 0V RS232 X10 1 5V RS485 PIN X10 RS232 Sub D 1 Enable RS232 0V 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS...

Page 18: ...back system X11 High Density Sub D Pin DA monitor RS422 Encoder Start Stop time of flight SSI 1 24V max 100mA 24V max 100mA 2 3 Aout1 4 Aout0 5 5V for encoder max 150 mA 6 A INIT Clock 7 A INIT Clock...

Page 19: ...of the device specific assignment in the online help which can be opened from the Compax3 ServoManager Maximum capacitive loading of the outputs 50nF max 4 Compax3 inputs 3 2 9 1 Connection of the di...

Page 20: ...on the encoder side Vcc 5V controlled on the encoder side Vcc 5V controlled on the encoder side 5 5V for encoder max 150mA 5V 5V 6 A Clock INIT Clock 7 A Clock INIT Clock 8 B COS COS STSP 9 SIN SIN 10...

Page 21: ...0 N8 September 2014 21 3 2 11 Mounting and dimensions Mounting 3 socket head screws M5 or by direct snapping on a 35 mm supporting rail according to DIN EN 50 022 Mounting material DIN rail clip and d...

Page 22: ...9 IP 20 Inputs And Outputs Controller type Compax3 F001 D2 8 control inputs 24 VDC 10 kOhm 4 control outputs Active HIGH short circuit proof 24 V 100 mA 4 analog current inputs 14 Bit 2 analog voltage...

Page 23: ...ion Operation storage transport 85 class 3K3 95 class 2K3 95 class 2K3 Relative humidity Elevation of operating site 1000m above sea level for 100 load ratings 2000m above sea level for 1 100m power r...

Page 24: ...panel LEDs via X10 12 Mounting and dimensions 21 N Notes on the Documents Supplied 3 P Packaging transport storage 8 Plug and connector assignment 13 Plug and connector assignment Compax3 Fluid 12 Plu...

Reviews: