Setting up Compax3
56
I11 T11 192-120101 N6 - March 2004
The actual position is set to 0 before each positioning. Thus the travel range has no
fixed zero point. All positionings are relative - in relation to the actual position.
0
0
0
START
START
START
Since the positioning mode (relative or absolute) can be selected additionally for
each positioning data record, mixed operation is possible too.
Execution of the positioning data records: sequential / single
positioning
With a START edge (X12/7=24VDC) after
!
Machine zero run or after the
!
"Deenergized state"
the selected positioning data record is executed.
!
On the next STARTedge the next positioning data record is executed
(irrespective of the set positioning data record address).
If the positioning data record address 0 is still present, the machine zero run is
executed.
!
With a repetition number >1 this can be the same positioning data record.
!
Subsequent STARTs execute the current positioning data record the number of
times corresponding to the repetition number.
!
The next start thereafter switches to the next positioning data record.
!
After the last positioning data record, the positioning data record 1 is executed
next.
!
(see on page 56 ) = 0 reads in the address new.
After a
STOP with termination
(see on page 58 ), the positioning address is read
in new.
After
STOP without termination
(see also on page 58 ) the sequential positioning
is interrupted; on the next START the sequential positioning is resumed with the
interrupted positioning data record.
1
E/I3
E/I4
E/I5
E/I6
START
1
1
1
0
0
0
0
home
--3--
--4--
x
x
x
x
x
x
x
x
--4--
0/1
0/1
1
2
3
4
5
1
1
1
2
1
x
x
x
x
--5--
0/1
1
2
3
4
5
1
2
Column 1: Positioning data record address
Column 2: Repetition counter
Action
Behaviour
START 1 after Power On
Machine zero run (home)
Positioning data record address irrelevant
START 2
Positioning data record address is read in
Positioning data record 3 is executed
Endless mode
Note
Sequential
positioning
Behaviour after
STOP
Example 1: