9.2 ‘Remote’ Operation (Using Pre-Defined Macro’s)
To run the drive ‘remotely’ (using either push-buttons, switches or PLC’s as opposed to a keypad), the
following steps need to be followed.
Note: This sequence assumes that the ‘Basic Drive Setup’ routine has been completed, as outlined
above.
Enable ‘Remote’ Control Mode
To enable ‘
Remote
’ Control Mode:
Remote Control Mode Selection
Onboard Keypad Display
6901 Remote Keypad Display
Press and hold the ‘
Stop
’ key for approx. 3
seconds as “
C … O … L
” disappears from the
display.
Press the ‘
L/R
’ key.
Once ‘
Remote
’ Control Mode is enabled, the drive will show the following status indication:
Remote Control Mode ‘Enabled’
Onboard Keypad Display
6901 Remote Keypad Display
The hand icon will disappear from the display.
The ‘
SEQ
’ & ‘
REF
’ LEDs will turn off.
Selecting & Loading A Macro
To select and load a pre-defined Macro:
- Navigate through the ‘
Setup
’ menu, to the ‘
Application
’ sub-menu:
Application Level Menu Overview
Onboard Keypad Display
6901 Remote Keypad Display
SEt
APP
P
1150
P
1152
P
1151
Setup
Application
Application
Application Lock
Load Application