11
Liquid tight cable outlet
Rubber gasket seal in lid recess.
Driver plug base to valve coil rubber
gasket supplied ( loose )
M3 x 40mm mounting screw
If required, Apply ‘lithium
grease’ under lid ( fill void )
and between driver plug
base, gasket and valve coil
connector.
Application Notes for Harsh Environments.
• Use care when re-assembling unit after adjustment and ensure that lid gasket is in place.
• DO NOT over tighten the central M3 x 40mm mounting screw.
• Ensure that flat rubber gasket ( supplied ) is fitted between valve coil and driver plug.
• For ‘high moisture’ applications apply ‘lithium grease’ between valve coil and driver plug base
before final assembly and mounting screw tightening process.
• For total immersion applications, follow above step and additionally fill driver plug lid with ‘lithium
grease’ after adjustment and before final assembly to form liquid proof seal around all potentiometers
and units plug base / valve coil joint.
Block Diagram.
PWM
F.E.T.
output
stage
‘Dither’
( PWM )
frequency
adjust.
I Min adjust
ECU PWM
signal I/P
Internal
PSU
Ramp
Generator
Current
Feedback
PWM ‘ f ’
generator
Output to
valve coil
interface
I Max ( 20 Turn potentiometer )
+Vin
0Vin
ECU 0V
700-00027-0, DFC-3 Plug Top Driver Unit.
PWM
To V