ELECTRICAL FEATURES

The DA750 unit is built to operate from either 115VAC or 230VAC (not interchangeably),

50/60 Hz., Single phase current. Line current at rated output is approximately 27 amperes

at 115 volts and 14 amperes at 230 volts. Check  "Data Nameplate" on the unit for correct

operating voltage.

The DA750 is wired at the factory for either 115VAC or 230VAC operating voltage.

Change over from one voltage to another can not be done in the field. Unit must be

returned to the factory for modification.

An automatic thermal reset/circuitbreaker is provided to prevent overheating and damage

to electrical components.

The current control potentiometer in conjunction with internal electrical circuit, provide

infinitely variable magnetizing and demagnetizing current control.

The power transformer operating in conjunction with an SCR module, transforms the high

voltage line input to low voltage, high amperage A.C. or Half-Wave DC output.  While

these components are fan cooled, they are designed for intermittent service at 750

amperes output. To avoid overheating and possible damage, a minumum duty cycle of

50% must be adhered to.

CAUTION:

Attaching less than 30' of 4/O cable (two 15' cables) will cause excessive line

current draw and possible overheating of parts.

CONNECTION

1. With current control in the "Off" position, connect the line cord to the properly fused

and grounded disconnect switch of proper rating. Consult "Data Nameplate" on the back

of the unit for correct operating voltage.

2. Turn the current control so that the unit powers "On".  A red pilot light will glow

indicating that there is power to the unit and that it is "On".

3. Plug in and twist clockwise two 15' 4/O magnetizing cables into the output terminals at

the front of the unit.

Note:

One cable must be connected to the "Common" output

terminal. The other cable must be connected to either the A.C. or HWDC cable

connector. Connect the two eitherend connectors or two lug connectors at the opposite

end of the cables to form a "loop".  Plug in the control cable and activate to check

operation for both AC and DC output.

For maximum output on either AC or half-wave DC, it is necessary to reduce the inductive

loop of the external cables as much as possible\; that is, the spacing between the

external  4/O cables must be kept at a minimum. If possible, the first ten feet of cable may

be bound of taped together for optimum current output.

NOTE

: When cables are used  as a coil with AC current, ammeter readings will be lower

due to coil/part  inductance.

Summary of Contents for DA750

Page 1: ...on It features infinitely variable magnetizing and demagnetizing current THE FOLLOWING SHOULD BE READ AND FULLY UNDERSTOOD SAFETY PRECAUTIONS PAGE 2 GENERAL DESCRIPTION PAGE 2 ELECTRICAL FEATURES PAGE 3 CONNECTION PAGE 3 CONTROLS ELECTRICAL PAGE 4 OPERATION PAGE 5 SERVICE DATA WARRANTY PAGE 6 SCHEMATIC DIAGRAM PAGE 7 Parker Research Corporation assumes no liability from any claims arising from the...

Page 2: ...ces a strong electromagnetic field which can be harmful to people with implanted Cardiac Pacemakers Personnel with such devices should not operate this machine and must stay a safe distance away from this machine and cable output area Contact the manufacturer of your Pacemaker for additional precautions and warnings GENERAL DESCRIPTION The DA750 is a extremely rugged and compact Magnetic Inspectio...

Page 3: ...ss than 30 of 4 O cable two 15 cables will cause excessive line current draw and possible overheating of parts CONNECTION 1 With current control in the Off position connect the line cord to the properly fused and grounded disconnect switch of proper rating Consult Data Nameplate on the back of the unit for correct operating voltage 2 Turn the current control so that the unit powers On A red pilot ...

Page 4: ...er to provide accurate current readings for both AC and half wave DC magnetizing currents OUTPUT TERMINALS Half wave DC current is obtained by connecting the magnetizing cables to the Common and Half Wave connectors AC current is obtained by connecting to the Common and A C connectors Always insert and then twist cable connectors clockwise to lock in position CONTROL CABLE RECEPTACLE This receptac...

Page 5: ...le into Control Cable Receptacle 3 Turn current control to position that gives desired current level 4 Make prod contacts with clean surface of part Place prod tips approximately six inches apart on either side of the line of suspected defect Press prod handle switch to initiate current flow Use very firm contact pressure to minimize chances of arcing and burning Ammeter will indicate magnetizing ...

Page 6: ... the DA750 at no charge less incoming freight charges for a period of one 1 year from the date of purchase Warranty will not apply to units that have been altered or to those units that have been used improperly In the event of malfunction return the unit prepaid to the factory Repair or replacement of the defective unit will be made at the discretion of Parker Research Corporation The repaired or...

Page 7: ...7 ...

Reviews: