background image

4

29

DESIGN FEATURES

Physical  Design

The amplifier is enclosed in a metal (steel) case of 2U height. The amplifier is designed

to  be  installed  into  a  standard  19"  rack.

The  amplifier  incorporates:

 power supply source;

 two similar amplifying monoblock units;

  input  module;

  indication  and  input  level  control  unit.

The  input  module  is  replaceable.

Power Supply Source

Common  for  both  channels.  The  power  supply  source  consists  of  a  soft-start  unit,  a

toroidal  transformer,  ac/dc  converters  and  a  filter  capacitor  PCB.

Cooling System

Fans  are  used  to  cool  the  output  stage.  The  cooling  system  is  independent  for  each

channel.  The  air  flows  backwards.  The  cooling  intensity  changes  progressively  in  the
process of  operation. On power-on  and when  the output power  is fairly low,  the fan  runs at
a low  speed thus  minimizing the  acoustic noise.  As the  output power  goes up  and so  rises
the  temperature  of  the  output  stage  heat  sinks,  the  fan  starts  blowing  harder,  thus
intensifying  the  cooling  process.

Output  Stage

The output stage is designed with the use of complementary pairs of TOSHIBA bipolar

transistors.  The  output  stage  is  based  on  Class  H  technology  with  double-level  power
supply.

FUNCTIONAL FEATURES

Output  Short-Circuit  Protection

The  amplifier  is  provided  with  individual  protection  for  each  channel  and  global

protection in the  bridge mode. The protective system  does not switch the amplifier  off, so it
resumes  its  unattended  operation  after  the  short-circuiting  conditions  are  gone.

Overload Protection

The  double-stage  overload  protection  system  provides  both  reliable  output  stage

protection  and  perfect  sonic  quality  even  under  overload.

In  case  of  a  short-time  overload  lasting  up  to  3  msec.,  (e.g.  overload  caused  by  a

sudden  drop  of  total  load  impedance),  only  the  output  stage  current  protection  goes  active
limiting  the current  running  through  the output  transistors  at  the safe  level.  In  this case  the
protection  system  does  not  preclude  the  amplifier  from  delivering,  for  a  short  while,  a  full
output  power  (without  any  output  voltage  reduction)  even  to  loads  of  very  low  impedance.

In  case  of  a  more  continuous  overload,  the  protection  system  activates  the  built-in

Clip-limiter, which reduces the level of the  input signal and eliminates the distortion, caused

by  hard  clipping.

DC  Output  Protection

The  amplifier  schematics  precludes  any    clicks  or  noise  occurring  during  the  power-

on/off  transition  processes  without  utilizing  any  relay  commonly  used  for  connecting  the

Frequency Response:

20Hz ... 20kHz

 

(

0.2dB, Pnom.)

10Hz ... 60kHz

 

(1dB, 1W)

Total  Harmonic  Distortion:

0.003%

 

(1kHz)

0.02 %

 

(20Hz ... 20kHz)

Slew Rate:

40V/µs

 

(channel)

, 80V/µs

 

(bridge)

Damping Factor:

 V4-900

MkIII

, V4-1200

MkIII

400

 

(1kHz, 8Ohm)

 V4-1800

MkIII

400

 

(1kHz, 8Ohm)

  V2-2400

MkIII

,  V4-2400

MkIII

600

 

(1kHz, 8Ohm)

Channel Separation:

60dB

 

(1kHz)

Signal-to-Noise Ratio:

100dB

 

(unweighted)

Input Impedance:

10 kOhm 

(balanced)

Sensitivity:

0.775V 

(standart model)

0.775V, 1.4V, 32dB

 ( * )

High-pass

Filter Cutoff Frequency**:

35Hz

High-Pass Filter Slope Rate**:

24dB/octave

Crossover Frequency***:

125Hz

Power Requirements:

~230V AC, 50/60Hz

Weight:

  V4-900

MkIII

14kg

  V4-1200

MkIII

15kg

  V4-1800

MkIII

16kg

  V2-2400

MkIII

18.5kg

  V4-2400

MkIII

18.5kg

Dimensions:

 width

482 mm

 height

96mm

 height in rack

2U

 depth

414 mm

 depth in rack

374mm

* Only when an input module with a sensitivity switch is installed.
** Only when an input module with a sensitivity switch or with a crossover is installed.
*** Only when an input module with a crossover is installed.

Summary of Contents for V4-900 MkIII

Page 1: ...O II Ltd Vinnitsa Ukraine www parkaudio2 com e mail park parkaudio2 com PROFESSIONAL POWER AMPLIFIERS V series V4 900 V4 1200 V4 1800 V4 2400 V2 2400 MkIII MkIII MkIII MkIII MkIII OWNER S MANUAL PARK...

Page 2: ...ACCESSORIES 1 Power Cord 1 ea 2 Owner s Manual 1 ea 3 Warranty 1 ea Printed in Ukraine...

Page 3: ...Panel 11 Rear Panel 12 Input Module with Sensitivity Switch 13 Input Module with Crossover 14 Cabel Requirements 15 Input and Output Connectors 16 Rack Mounting Requirements 17 AC Power Requirements 1...

Page 4: ...lifier can yield dangerous output voltage Do not touch the non insulated cable parts connected to outputs of the unit in operation CAUTION The amplifier yields high output power The manufacturer shall...

Page 5: ...y in the schematics elements output power and weight Unless specified otherwise the word amplifier hereinafter applies to any of the above models UNPACKING The manufacturer s quality control system pr...

Page 6: ...ty even under overload In case of a short time overload lasting up to 3 msec e g overload caused by a sudden drop of total load impedance only the output stage current protection goes active limiting...

Page 7: ...output stage of the respective channel This status is indicated by a brightly full lit ALARM LED The amplifier automatically resumes its operation in the reverse order after the output stage transist...

Page 8: ...input module Input Filter only for input modules with a sensitivity switch or with a crossover To improve the performance of speaker systems the amplifier incorporates a switch selectable high pass 4...

Page 9: ...channels drive two separate loads from two separate signal sources MONO two channels drive two separate loads from a single input signal source BRIDGE two channels drive the same load from a single si...

Page 10: ...Amplifier 1 CHANNEL2 SWITCHED OUTPUT HI position CROSSOVER LO position CHANNEL1 SWITCHED OUTPUT HI position CROSSOVER LO position AMPLIFIER BLOCK DIAGRAM Power amplifier Power amplifier Limiter Limit...

Page 11: ...ource To Channel 2 Input Signal Source Channel 2 Satellite Channel 1 Satellite Channel 2 Subwoofer Channel 1 Subwoofer AMPLIFIER BLOCK DIAGRAM for input modules with a sensitivity switch 775V 1 4V 32d...

Page 12: ...R HI position AMPLIFIER BLOCK DIAGRAM for input modules with crossover CROSSOVER CROSSOVER HF LF HF LF HI FULL RANGE LO CROSSOVER LEVEL LEVEL HI FULL RANGE LO CROSSOVER Power amplifier Power amplifier...

Page 13: ...te Channel 2 Subwoofer Channel 1 Subwoofer FRONT PANEL Power switch LEVEL input signal attenuators for channel 1 2 respectively ALARM LEDs Indicate alarm status and protection of the respective channe...

Page 14: ...two channels drive two separate loads from two separate input signal sources BRIDGE two channels drive a common load from a single input signal source INPUT balanced input XLR female for Channel 1 in...

Page 15: ...n THROUGH line outputs for Channel 2 1 respectively XLR male Are used to deliver input signal along the respective channel to the input of another amplifier THROUGH connectors are parallel to INPUT co...

Page 16: ...al delivered to the output of the respective channel CROSSOVER switch for channel 1 2 respectively Selects the desired frequency range to be amplified HI LO FULLRANGE The BRIDGE mode the frequency ran...

Page 17: ...loss to the load at other cable lengths For example if you plan to deliver 500Watts to 8 Ohm load through 20m of 1 5 mm2 cable the power loss in the cable would be 2 9 x 2 5 8 of 500W or 29W lost in...

Page 18: ...V4 1800MkIII V4 2400MkIII V2 2400MkIII amplifiers are supplied with a three conductor grounded AC power cord and should be plugged into a standard 3 wire grounded electrical outlet which supplies 230...

Reviews: