background image

REAR PANEL

 

 

 

 

 

 

 

 

T

O

REDUCE

THE

RISK

OF

FIRE

OR ELECTRIC

SHOCK

 

 

 

 

 

 

 

 

  

DO

NOT

EXPOSE

THIS

EQUIPMENT

T

O

RAIN

OR

MOISTURE.

 

 

 

DO

NOT

REMOVE

COVER.

 

 

 

 

NO

USER

SER

VICEABLE

P

ARTS

INSIDE.

 

 

 

 

 

REFER

SER

VICING

T

O

QU

ALIFIED

SER

VICE

PERSONNEL.

W

ARNING

INPUT

INPUT

PUSH

PUSH

MODE

CH 3

CH 3- 4

CH 4

THRU

MONO

STEREO

BRIDGE

THRU

OFF

CROSSOVER

THRU

CH 4

CH 3

OUTPUT

4   min

BRIDGE

8   min

ON

OFF

ON

CROSSOVER

THRU

1

2

1

2

1
2

4   min

Use  INPUT CH 3

for MONO

& BRIDGE MODE

CH 4

4   min

1
1

INPUT

INPUT

PUSH

PUSH

MODE

CH1

CH 1-2

CH 2

THRU

MONO

STEREO

BRIDGE

THRU

OFF

CROSSOVER

THRU

CH 2

CH 1

OUTPUT

4   min

BRIDGE

8   min

ON

OFF

ON

CROSSOVER

THRU

1

2

1

2

1
2

4   min

Use  INPUT CH 3

for MONO

& BRIDGE MODE

CH 2

4   min

1
1

MAINS IN

RISK OF ELECTRIC SHOCK

CAUTION

DO NOT OPEN

5

6

7

1

2

3

4

21

22

23

11

20 19 18

15

16

17

14 13 12

10

8

9

PROFESSIONAL POWER AMPLIFIER

model 

DF1404 MkII

230V  50/60Hz  550VA

Serial No

Park Audio II, Ltd    M

  ade i n U

  kraine

THRU

 – line outputs for сhannels 4, 3, 2, 1, respectively (

XLR

 male).

Are used to deliver input signal along the respective channel to the input of 
another amplifier.
THRU connectors are parallel to INPUT connectors of respective channels.

INPUT

   –   balanced inputs (

XLR

 female) channels 4, 3, 2, 1, respectively. 

Inputs for сhannels 1, 3 are also used to supply the input signal for channels 
1, 2 and channels 3, 4 functioning in the MONO and BRIDGE mode.

MODE

 switch for channel 3 and 4:

– MONO – channels 3,  4 drive two loads from a single input signal source;
– STEREO – channels 3, 4 drive two loads from two separate input signal 
sources;
– BRIDGE – channels 3, 4 drive a common load from a single input signal 
source.

MODE

 switch for channels 1 and 2:

– MONO – channels 1, 2 drive two loads from a single input signal source;
– STEREO – channels 1, 2 drive two loads from two separate input signal 
sources;
– BRIDGE – channels 1, 2 drive a common load from a single input signal 
source.

MAINS IN

 – power cord socket for 230 V AC 50 / 60 Hz grounded mains.

CROSSOVER

 switches for channels 4, 3, 2 and 1, respectively, to select the 

required frequency band: 
– TOP – higher frequency signal component;
– SUB – lower frequency signal component; 
– THRU (Full Range).
Switches for channels 1, 3 are also used to select the required frequency 
band for channels 1, 2 and channels 3,  4 functioning in the BRIDGE mode.

2 4 7 9

11

12 17 18 23

1 5 6 10

3

8

8

Summary of Contents for DF series

Page 1: ...PROFESSIONAL FOUR CHANNEL CLASS D POWER AMPLIFIER DF1 404 MKII Owner s Manual DF series R...

Page 2: ...ACCESSORIES 1 Power Cord 1pc 2 Owner s Manual 1pc 3 Warranty 1pc...

Page 3: ...onnected to the unit in operation CAUTION The high sound pressure level of speaker systems generated by high output power delivered by the amplifier may be hazardous to your hearing Please take adequa...

Page 4: ...s of channels bridged To ensure the most advantageous and faultless operation of the amplifier please read this Manual before use UNPACKING The manufacturer s quality control system provides for caref...

Page 5: ...erference with long input connecting cables Line Outputs The amplifier line outputs are parallel to the inputs each along the respective channel and provide for parallel connection of several amplifie...

Page 6: ...full range signal is selected individually for each channel with a slide switch The crossover frequency point is factory preset generally to 125Hz However it can be changed by replacing the crossover...

Page 7: ...ical signals of powerful high frequency spectrum Thermal Protection The continuous operation support protection system is common for four channels When the heat sink becomes heated over 50 the fan goe...

Page 8: ...SPEAKER OUTPUT THRU INPUT THRU TOP THRU SUB CROSSOVER LEVEL LEVEL 1 HF LF TOP THRU SUB CROSSOVER CH 3 INPUT ON OFF HI PASS FILTER 45 Hz 45Hz 150Hz 150Hz HF LF CH 4 ON OFF HI PASS FILTER 45 Hz 150Hz 15...

Page 9: ...clip LEDs for Channels 1 2 3 and 4 respectively They indicate overload condition causing distortion activation of thermal protection system which disables the respective channel the SIGNALLED goes of...

Page 10: ...ther amplifier THRU connectors are parallel to INPUTconnectors of respective channels INPUT balanced inputs XLR female channels 4 3 2 1 respectively Inputs for hannels 1 3 are also used to supply the...

Page 11: ...tor is interlinked with channel 2 output while channel 3 output connector with channel 4 output thus making it possible to use a single NL4FC connector wired accordingly to connect channel 1 and 2 lou...

Page 12: ...hazard Since the power applied to the loudspeaker is of primary concern in system design we have included the table below to allow you determine the appropriate wire gauge for your application Power L...

Page 13: ...use SpeakON NL4FC See the wiring on the figures below CAUTION Never attempt to jumper or otherwise link up any pins of output connectors 2 1 3 2 1 3 1 1 1 2 1 2 1 2 1 2 1 2 1 2 XLR male XLR female Co...

Page 14: ...which supplies 230VAC 50 60Hz In the event of line voltage sag the unit will continue to operate normally albeit with less power The mains lower voltage limit for the amplifier to retain its operabili...

Page 15: ...4Ohm Never attempt to jumper or otherwise link up any pins of SpeakON output connectors TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT REMOVE COVE...

Page 16: ...mpt to jumper or otherwise link up any pins of SpeakON output connectors TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE DO NOT REMOVE COVER NO USER SERVI...

Page 17: ...s 1 and 3 with a SpeakON NL4FC connector wired for bridge connection Set the MODE switches for Channels 1 2 and Channels 3 4 to BRIDGE Adjust the input signal level with the LEVELattenuators for Chann...

Page 18: ...Filter Note Any pair of channels 1 2 or 3 4 can be operated in the bridge mode or individual mode if properly connected and set up The loudspeaker rated impedance should be at least 4Ohm for individu...

Page 19: ...ut Filter Note Any pair of channels 1 2 or 3 4 can be operated in the bridge mode or individual mode if properly connected and set up The loudspeaker rated impedance should be at least 4Ohm for indivi...

Page 20: ...temperature has exceeded 65 thus activating the thermal protection system Sound Distortion Only SIGNALLED is ON applied input signal is distorted before it gets to the amplifier loudspeakers are dama...

Page 21: ...1kHz Signal to Noise Ratio 98dB unweighted Input Impedance 10kOhm balanced Sensitivity 0 775V Crossover Frequency 125Hz basic model High pass Filter Cutoff Frequency 45Hz High Pass Filter Slope Rate 2...

Page 22: ...445 max 482 466 76 88 96 38 324 362 DIMENSIONS 20...

Page 23: ...PARK AUDIO II Ltd Vinnytsia Ukraine www parkaudio ua e mail park parkaudio ua R...

Reviews: