background image

– 24 –

Summary of Contents for LC series

Page 1: ...LC Family 2016 PARI GmbH Spezialisten f r effektive Inhalation 022D0103 O 06 16...

Page 2: ......

Page 3: ...9 Intended use 9 Contraindications 9 Product variants and combinations 10 Material information 10 Operating life 10 INHALATION 11 Assembling the nebuliser 11 Filling with medication 12 Performing the...

Page 4: ...MISCELLANEOUS 22 Disposal 22 Technical data 22 Explanation of symbols 23 Contact 23 4...

Page 5: ...available for medical specialists If these instructions for use are lost you can request another copy from PARI GmbH see Contact page 23 The instruc tions for use for some products can be retrieved on...

Page 6: ...and the ac cessories out of the reach of babies and infants Special masks may be obtained for treating babies and infants who are not yet able to inhale using the mouthpiece The nebulisers are only d...

Page 7: ...tion Before every use and cleaning wash your hands thoroughly Make absolutely sure you also carry out cleaning and drying before using the device for the first time For cleaning and disinfection alway...

Page 8: ...ined in your package If anything is missing please notify the dealer from whom you purchased the PARI product immediately 1 Nebuliser lower section 2 Nozzle attachment 3 Inspiratory valve 4 Mouthpiece...

Page 9: ...d by using PARI nebulisers with compressors or accessories from other manufacturers Please read and follow the instructions for use of the com pressor and of the accessories you are using 2 3 Intended...

Page 10: ...nts who are not yet able to inhale using the mouthpiece 2 6 Material information Polypropylene Nebuliser lower section nozzle attachment inspiratory valve mouthpiece child mask Thermoplastic elastomer...

Page 11: ...parts Please also follow the instructions for as sembly given below Damaged components and or an in correctly assembled nebuliser may impair functioning of the nebuliser and thus treatment as well Ins...

Page 12: ...ask Attach the child mask to the nebuliser When using a mask make sure that the expiratory valve plate is pressed out so you can exhale freely during an inhalation session 3 2 Filling with medication...

Page 13: ...ng max level 8 ml Overfilling can greatly impair the nebulisation of medication max 8 ml Attach the inspiratory valve to the nebuliser If you are to inhale several medications one after the other in o...

Page 14: ...onnect the connection tube to the compressor and switch the compressor on Sit in an upright position and relax Take the nebuliser out of its holder and hold it upright Take the mouthpiece between your...

Page 15: ...nebuliser into its individual parts Carefully pull the blue expirat ory valve out of the slot in the mouthpiece The valve must still be attached to the mouth piece Rinse all components of the nebulis...

Page 16: ...ng disinfect the dismantled nebuliser and accessor ies used except for the connection tube Effective disinfection is only possible if the nebuliser has been cleaned Information when using masks with r...

Page 17: ...use a disinfector with a runtime of at least 6 minutes Regarding disinfection the duration of the dis infection procedure and the quantity of water required for this follow the instructions for use of...

Page 18: ...ector with enough space between them to allow the steam to reach all surfaces reliably Maintain the following times when disinfecting Wattage Disinfection time Cooling time 850 950 4 min 2 min 600 850...

Page 19: ...ry hot Therefore it is essential to wait for the cooling time to pass before taking the parts out otherwise there is a risk of burns Inadequate or ineffective disinfection encourages the growth of bac...

Page 20: ...n time are adhered to and if all individual parts are completely immersed in the solution for the entire application time There must not be any air pockets or bubbles Prepare a 2 solution of Bomix plu...

Page 21: ...nfection Replace any broken misshapen or seriously discoloured parts 4 6 Drying and storage Place all parts on a dry clean and absorbent surface and let them dry completely Wrap the nebuliser in a cle...

Page 22: ...espective member countries 5 2 Technical data Aerosol data according to DIN EN 13544 1 is available on re quest from PARI GmbH Operating gases Air oxygen Minimum flow 3 0 l min Corresponding minimum o...

Page 23: ...equirements as set forth in Appendix I of Directive 93 42 EEC concerning medical devices Please follow the instructions for use Order no Lot no 5 4 Contact For all product information and in the event...

Page 24: ...24...

Page 25: ......

Page 26: ...PARI GmbH Moosstrasse 3 82319 Starnberg Germany Tel 49 0 81 51 2 79 0 Fax 49 0 81 51 2 79 101 E Mail info pari de www pari com 2016 PARI GmbH Spezialisten f r effektive Inhalation 022D0103 O 06 16...

Reviews: