Front Panel Power Button and Display 

 

 

 

 

Power Button 

If the Turn On Options switch is set to the Manual position, pushing the Power button turns on all 
channels/zones.  When turned on the ring around the Power button and the 4 channel status indicators will 
illuminate green.  Pushing the Power button again turns off all channels/zones.  

If the rear panel Turn On 

Options switch is not set to 

Manual

 the front panel power button will not operate.  

 

 

Channel Indicators (1 - 4) 

The channel numbers on the front panel illuminate according to each 

channel’s operational status.  Both 

channel number indicators for a zone will always illuminate together.  When a zone is turned on, both of the 
channel number indicators for that zone will illuminate green.  For zones that are not turned on the 
corresponding channel pair indicators will not illuminate. 
 
Channel indicators are illuminated by channel pairs that correspond to two zones:  
 

Ch 1-

 

2 = Zone 1              Ch 3-

 

4 = Zone 2 

 

Green:

 Indicates normal operation.  

 

   

Red:

 Indicates the protection circuit has suspended operation of that channel pair to protect them from an 

overload or because one or both of their speaker wires are short-circuited.  The indicators might also 
alternate flashing green and red, depending on the musical content and volume levels.  This also indicates a 
problem.  Both channel number indicators for a zone will always illuminate the same color.  Causes for the 
front panel indicators to illuminate red are: 
 

 

The speaker outputs for one or both channels of that zone are short-circuited (negative 
to positive) either at the amplifier, at the speaker or somewhere along the speaker wire.

 

 

The negative speaker terminals have been combined (L- to R-). 

 

Too many speakers are connected and the combined impedance is below 2 ohms. Or 
below 4 ohms when that zone is set to Bridged Mode. 

 

The unit has overheated.  Provide more ventilation or use a fan. 

 

The AC line voltage has exceeded the maximum allowed (132V when set for 115V or 
264V when set for 230v, 

depending on your region’s mains voltage). 

 

The amplifier has been damaged. 

 

Checking for Short Circuits on the Speaker Outputs 

If your ZoneMaster 450

’s front panel indicators are illuminated red or alternate illumination between green 

and red this indicates a problem.  Your first step is to immediately turn off the amp.  The most likely cause 
will be a short circuited speaker connection.  To check for this type of fault temporarily unplug both of the 
green speaker output connecting blocks.  Now turn the amp back on and play music.  If the front panel 
lights now illuminate green then 

you’ve eliminated the amp as the source of the problem.  Please check 

your speaker wires and attached speakers for short circuits or impedance below 2 ohms in Stereo Mode or 
4 ohms in Bridged Mode. 
 

Summary of Contents for ZoneMaster Model 450

Page 1: ...TM M M ZoneMaster Model 450 Universal Four Channel Amplifier Owner s Manual...

Page 2: ...Parasound ZoneMaster 450 Owner s Manual Page 2...

Page 3: ...e prong grounding plug This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat...

Page 4: ...Parasound ZoneMaster 450 Owner s Manual Page 4...

Page 5: ...dealer invoice and store it inside the ZoneMaster 450 s carton If the ZoneMaster 450 should require warranty repair you will need its original carton and foam packing inserts to ship it Please do not...

Page 6: ...Speaker Level Input Connector 9 Speaker Impedance and Paralleling Multiple Speakers 10 Rear Panel Mode Switch 11 Channel Level Controls and Uses 12 Turn On Options 13 Selecting Audio Trigger or 12V T...

Page 7: ...k or any other enclosed space You should never install the ZoneMaster 450 in an unventilated equipment cabinet or compartment because hot air will not exhaust adequately to prevent overheating Even a...

Page 8: ...ng Mexico as well as in Taiwan In some countries such as Brazil AC voltage varies by region Most other countries require setting this switch to 230V With the 230V setting the ZoneMaster 450 can operat...

Page 9: ...akers that are already connected directly to the host receiver or amplifier Audio connected to the Speaker Level input connector will be routed to the Left and Right inputs of zone 1 Speaker level aud...

Page 10: ...onnect multiple speakers to each channel This is done by simply twisting the two positive speaker wires together and connecting them to the positive speaker output on the 450 The same should be done w...

Page 11: ...dged mode can be used to drive larger or less efficient speakers in large spaces where more power is needed A typical use of the bridged mode would be to run Zones 1 and 2 in Bridged Mode to power a s...

Page 12: ...450 s Level controls until the volume level in the room or zone is as high as you or the home owner might ever want it to be This is the most appropriate setting for the Level controls because it will...

Page 13: ...vent the amplifier from being turned on or off manually or by mistake Note The 12V turn on trigger circuit in the ZoneMaster 450 requires a mere 5mA from the 12V trigger source Audio Each zone can be...

Page 14: ...nt and volume levels This also indicates a problem Both channel number indicators for a zone will always illuminate the same color Causes for the front panel indicators to illuminate red are The speak...

Page 15: ...e channel sees only 4 ohms If two 4 ohm speakers are attached the channel sees only 2 ohms The zone may have overheated and will not resume operation until it cools down Ensure that you have provided...

Page 16: ...re outside the Warranty Unit is not eligible for repair under the terms of the Parasound warranty if 1 Unit was not purchased from a Parasound Authorized Dealer 2 You do not have the original bill of...

Page 17: ...50 Watts 8 Total gain 29 dB Level controls set to Maximum S N Ratio 112 dB input shorted IHF A weighted DC Trigger Requirements 9 Vdc to 12 Vdc 5 mA Audio Trigger Requirements 2 mV audio signal AC Po...

Page 18: ...____________ ____________________________________________ ____________________________________________ ____________________________________________ ____________________________________________ _______...

Page 19: ...Parasound ZoneMaster 450 Owner s Manual Page 19...

Page 20: ...Parasound ZoneMaster 450 Owner s Manual Page 20 Parasound Products Inc 2250 McKinnon Ave San Francisco CA 94124 Customer Service 415 397 7100 www parasound com...

Reviews: