Parasound
®
ZoneMaster
™
1250 Owner’s Manual
Page 14
Front Panel Power Button and Display
Power Button
Pushing the Power button turns on all channels/zones. When turned on the ring around the Power button
and the 12 channel status indicators will illuminate green. Pushing the Power button again turns off all
channels/zones.
If the rear panel Turn On Options switch is not set to “
Manual All”
the front panel
power button will not operate.
Channel Indicators (1 - 12)
The channel numbers on the front panel illuminate according to each channel’s operational status. Both
channel number indicators for a zone will always illuminate the same color. When a zone is turned on, both
of the channel number indicators for that zone will illuminate green. When the Turn On Options switch is set
to “
Audio/12V By Zone”
only the channel numbers for zones that are triggered on will illuminate green. For
zones that are not turned on the corresponding channel pair indicators will not illuminate.
Channel indicators are illuminated by channel pairs that correspond to six zones:
Ch 1-
2 = Zone 1 Ch 3-
4 = Zone 2 Ch 5
-
6 = Zone 3
Ch 7-
8 = Zone 4 Ch 9
-10 = Zone 5 Ch 11-
12 = Zone 6
Green:
Indicates normal operation.
Red:
Indicates the protection circuit has suspended operation of that channel pair to protect them from an
overload or because one or both of their speaker wires are short-circuited. The indicators might also
alternate flashing green and red, depending on the musical content and volume levels. This also indicates a
problem. Both channel number indicators for a zone will always illuminate the same color. Causes for the
front panel indicators to illuminate red are:
The speaker outputs for one or both channels of that zone are short-circuited (negative
to positive) either at the amplifier, at the speaker or somewhere along the speaker wire.
The negative speaker terminals have been combined (negative to negative).
Too many speakers are connected and the combined impedance is below 2 ohms.
The unit has overheated.
The AC line voltage has exceeded the maximum allowed (132V when set for 115V or
264V when set for 230v, depending on your region’s mains voltage).
The amplifier has been damaged.
Checking for Short Circuits on the Speaker Outputs
If your ZoneMaster 1250’s front panel indicators are illuminated red or alternate illumination between green
and red this indicates a problem. Your first step is to immediately turn off the amp with its master AC power
switch (above the AC cord inlet). The most likely cause will be a shorted circuited speaker connection. To
check for this type of fault temporarily unplug both of the zone’s two green speaker connecting blocks (A
and B). Now turn the amp back on and play music. If the front panel lights now illuminate green then
you’ve eliminated the amp as the source of the problem. Please check your speaker wires and attached
speakers for short circuits.