Parasound HCA-2205A Owner'S Manual Download Page 5

-5-

Introduction

Congratulations on your purchase of this precision audio component and thank you for your selection
of Parasound. Your Parasound power amplifier was designed by renowned circuit designer John Curl
to meet or surpass the stringent standards required by Lucasfilm for use in THX Home Cinema
systems. Please take a few moments to read these instructions so that you may fully understand the
capabilities of your new Parasound power amplifier.

Unpacking

Carefully unpack your amplifier and remove all the enclosed accessories. Be sure to inspect the unit
for any possible shipping damage. If you see any, contact your Parasound Dealer immediately. Save
all the packing material in case you need to ship the amplifier for repair. Before you proceed, find the
serial number located on the rear panel of your amplifier and record it here for reference:

Serial #____________________

Date of Purchase____________________

Installation and Rack Mounting

Locate your amplifier away from heat sources such as air ducts and radiators. Always mount the
amplifier horizontally and make sure that your cabinet or shelf can support its weight. It is best to
provide a separate shelf for your amplifier rather that stacking it directly above or below your other
components.

The HCA-2205A occupies four rack spaces (7") in a standard 19 inch equipment rack. Be sure to use
heavy duty mounting bolts to and nylon shoulder washers on both sides of the faceplate to avoid
scratching the amplifier’s front panel and also to help prevent ground loops. Contact Middle Atlantic
Products at (201) 839-1011 to obtain any rack mounting hardware you may need. When rack
mounting the HCA-2205A, have someone help support the unit while you bolt the component to the
rack rails.

Ventilation Requirements

To insure safe and reliable operation, it is very important that the amplifier has plenty of ventilation to
prevent overheating and automatic shut down from its thermal protection circuitry. Please observe the
following ventilation guidelines when installing your amplifier in a cabinet or other enclosed area:

1)  If you are not using a fan, allow at least six inches on each side and above the amplifier, and do not

close off the front with a cabinet door or panel.

2)  If you are enclosing the amplifier within an equipment cabinet, use a fan to draw in cool air and

exhaust warm air. Two vent holes are required: one for intake and one for exhaust.

3)  Do not place the amplifier on carpeting that will obstruct the air flow into the bottom of the

amplifier chassis and heatsinks.

4)  Avoid stacking components. If you do stack components, you must use a fan to circulate the warm

air that will quickly become trapped between them when they are powered on.

Summary of Contents for HCA-2205A

Page 1: ...A N U A L HCA 2205A Five Channel High Current Power Amplifier Power H C A 2 2 0 5 A H i g h C u r r e n t M u l t i A m p l i f i e r L U C A S F I L M L U C A S F I L M Normal AC Line 3 4 5 2 1 L U...

Page 2: ...r the HCA 2205A 6 Speaker Connections 6 AC Power Connections and AC Grounding 6 DC Trigger Connection 7 Operating Your HCA 2205A 7 Maintaining Your Parasound Amplifier 8 In Case of Trouble 8 Special F...

Page 3: ...This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of...

Page 4: ...r Consumption 2000 W Fuse T15A 250 V CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN AC 120V 50 60Hz Input Ch 1 Ch 1 Ch 1 Ch 1 Ch 1 Carry Handle Input Connectors and Level Controls AC Cord Connector Speake...

Page 5: ...nents The HCA 2205A occupies four rack spaces 7 in a standard 19 inch equipment rack Be sure to use heavy duty mounting bolts to and nylon shoulder washers on both sides of the faceplate to avoid scra...

Page 6: ...e terminated with 1 4 spade lugs or banana plugs to the five way binding posts of your power amplifier If you use bare wire without terminals make sure you remove only enough insulation so the wire ca...

Page 7: ...n Press the upper side to turn the unit on manually press the lower side to turn the unit off Automatic Turn On When the power switch is in the off position the power amplifier can be turned on with a...

Page 8: ...uires no periodic maintenance and has no user serviceable parts inside To avoid the risk of electric shock do not remove the top cover The amplifier s exterior can easily be cleaned with a soft cloth...

Page 9: ...the unit will be returned to you via prepaid UPS In the case of a non warranty repair contact us and we will advise you of the repair charges before you ship the unit to us The same packing and Return...

Page 10: ...nic Distortion 0 03 at full power 0 01 typical levels IM Distortion 0 03 TIM Unmeasureable Dynamic Headroom 1 5 dB Interchannel Crosstalk 80 dB at 1 kHz 60 dB at 20 kHz Input Impedance 33 k Input Sens...

Page 11: ...ty becomes void if the product has been damaged by alteration misuse accident or neglect Alteration includes any removal obscuration or defacement of its serial number This warranty becomes void if th...

Reviews: