Parasound HCA-2200II Owner'S Manual Download Page 2

Placement of your HCA-2200II

Keep your Parasound HCA-2200II out of direct sunlight and away from windows which could ever be left open to let
in rain. It should be placed away from heat sources such as hot air ducts or radiators. Make sure your cabinet or shelf
can support its weight!

Do not place the unit directly on a pile carpet that could interfere with air flow into its bottom vent openings or heat
sinks. If you place the HCA-2200II on the floor near your speakers, put it on a piece of wood to elevate it above the pile
of the carpet. If you stack your components, it is better to place the HCA-2200II alongside your other components.

The HCA-2200II is biased well into Class A, resulting in noticeably warm operation which could disturb components
stacked on top of it. If it is inside a cabinet, allow ample ventilation. Very sensitive low level sources placed too close
might pick up some hum radiated from its enormous powersupply.

Rack Mounting the HCA-2200II

The HCA-2200II can be mounted in a standard EIA 4 unit 19" rack. Make sure you select heavy duty mounting bolts
and nuts and use washers under the heads of the bolts to avoid scratching the amplifier's anodized front panel. Do not
attempt to hold the unit in place yourself while you attach the bolts and nuts - have someone support the unit while it is
being attached to the rack.

Making Connections

 

Before making any signal or speaker connections, make sure your power amplifier is turned off.

When making connections, make sure there is no strain or tension on input leads or speaker wires that could cause them
to pull loose later on.

lnput connections

In most stereo systems, you will use the gold-plated RCA jacks for the Right and Left channels. Make sure these are
consistent with the right and left outputs from your preamplifier.

For professional applications you can use the alternate XLR (often called "Cannon") input connectors. The XLR inputs
are for balanced lines whose ground is a third wire, separate from the audio and - wires. The HCA-2200II
employs this industry standard pin configuration:

Pin 1    Ground  Balanced signal lines are preferred for long signal runs to reduce hum pickup
Pin 2    + signal   They are also useful in areas where excessive RF or 60 Hz television
Pin 3    - signal    broadcast synch. signals might interfere.

Some of the finest high end preamplifiers, including the Parasound P/FR-2000 and P/LD- 1500, provide balanced line
outputs. If your preamplifier is so equipped, you may prefer to use the balanced connections which increase immunity
to external noise. Be certain to check the pin configuration for your preamplifier's balanced line outputs and, if neces-
sary, reverse the wires at one end of the right and left cables so each preamp goes to the HCA-; each
preamplifier - goes to the HCA-2200II's - ; each preamplifier ground goes to the HCA-2200II ground.

Note Balanced/Unbalanced lnput Select Switches

Select the inputs, XLR or RCA jack, which you have connected to the HCA-2200II Do not change the left and right

channel input selector switches while the amplifier is operating!

Summary of Contents for HCA-2200II

Page 1: ...dboard cartons Save your cartons and the styrofoam inserts for future safe transport in case you move or the unit ever requires shipping for repair Note the inner printed carton is not itself strong e...

Page 2: ...plifier is turned off When making connections make sure there is no strain or tension on input leads or speaker wires that could cause them to pull loose later on lnput connections In most stereo syst...

Page 3: ...ced or unbalanced inputs 4 Mono Bridging Selector 5 Speaker Terminals 6 Main Fuse 7 AC Power cord receptacle 8 Right channel B B rail fuses 9 Left channel B B rail fuses 10 Carry handles Front Panel 1...

Page 4: ...ker terminal and the Right channel red speaker terminal The Left and Right black terminals are not connected You must also move the Mono Stereo toggle switch up to mono before turning on the amplifier...

Page 5: ...he current draw exceeds the ratings of most preamplifier s power switches and power cords and could cause premature failure of the switch not to mention degrada tion of the sound If you use an externa...

Page 6: ...heat LEDs The Overheat LEDs for Right and Left channels will only illuminate if the HCA 2200II starts to approach its maximum safe operating temperature Multiple temperature sensors continuously monit...

Page 7: ...mplifier turn it off before moving wires If the same channel stays out it indicates trouble with the power amplifier itself We suggest you contact your authorized Parasound dealer or call Parasound Te...

Page 8: ...Rate 135V second Frequency Response 2Hz 95kHz 0 1 5dB Total Harmonic Distortion 0 05 at full power 0 009 typical levels TIM Unmeasurable IM Distortion 0 03 Dynamic Headroom 1 5dB lnterchannel Crosstal...

Page 9: ...direct coupled without inductors DC servo direct coupled audio circuits with 0 3Hz rolloff Linear tracking instantaneous acting DC servos Pure Class A operation up to 6 watts output Class AB 1 therea...

Page 10: ...ive articles on advanced circuit design and the influence of different capacitor types on the reproduction of music He designed the Symmetry electronic crossover SOTA head amplifier and collaborated w...

Page 11: ...fier In many cases this will eliminate the problem If this fails to cure the hum it will be necessary to reverse the way theAC plug of the HCA2200II inserts into the wall socket Please do not cut off...

Page 12: ...used in residential non commercial situations The warran tor assumes no liability for property damage or any other incidental or consequential damage whatsoever which may result from the failure of t...

Reviews: