background image

HCA-1200 Specifications

                                 

                             Specifications subject to change without notice.

Continuous Power output - stereo

200 watts RMS x 2, 20Hz-20kHz, 8 

300 watts RMS x 2, 20Hz-20kHz, 4 

Continuous Power output - mono

600 watts RMS, 20Hz-20kHz, 8 

600 watts RMS, 20Hz-20kHz, 4 

Current Capacity

40 amperes continuous
57 amperes peak, up to 200msec.

Slew Rate

100V/

µ

second

Frequency response

8Hz-90kHz, +0/-3dB

Total Harmonic Distortion

< 0.08% at full power
< 0.03% typical levels

TIM

Unmeasurable

IM distortion

< 0.1%

Dynamic Headroom

> 1.5dB

Input impedance

30 k

S/N ratio

>110dB, input shorted, IHF A weighted

Damping factor

Over 120 at 20Hz

Dimensions

17 1/4" wide x 5 1/2" high x 12" deep; 19" wide using RMK-1000 rack mount

Weight

38 lbs.

Special Features

1kVA toroid power transformer

60,000

µ

fd gold capacitors in power supply

60MHz output transistors, in AB mode

Cascode Class A J-FET input stage

- 7 -

Linear Hi-Z FET driver stage

Gold-plated input jacks

Multiple relay protection

Mono bridgeable

Summary of Contents for HCA-1200

Page 1: ...stage assure flawless reproduc tion You have made an excellent choice Please take a few moments now to read these instructions thoroughly so you may fully understand the sophisticated capabilities of...

Page 2: ...ice personnel WARNING To prevent fire or shock hazard do not expose this unit to rain or moisture Rear Panel I RCA input jacks 2 1 4 input phone jacks 3 Stereo mono bridging switch 4 Speaker terminals...

Page 3: ...ck to accommodate it properly To attach the RMK 1000 first remove the three bolts at each side of the cover closest to the front panel Use the 6 longer bolts supplied in the rack mount kit to attach b...

Page 4: ...the amplifier functions for either the or half of the musical waveform Thus each channel sees one half the speaker s impedance Use of an 8 speaker means that the load for each channel is 4 And for a...

Page 5: ...rogram material High Temp LEDs These will alert you to a pending thermal overload of the unit If the amplifier is overdriven as it builds up heat thermal tracking sensors will activate protection circ...

Page 6: ...is unit first recheck all your connections If one channel is inoperative the trouble maybe caused by another component or even a defective hookup cable If only one channel is out for all sources try r...

Page 7: ...B Total Harmonic Distortion 0 08 at full power 0 03 typical levels TIM Unmeasurable IM distortion 0 1 Dynamic Headroom 1 5dB Input impedance 30 k S N ratio 110dB input shorted IHF A weighted Damping f...

Page 8: ...tuations The warrantor assumes no liability for property damage or any other incidental or consequential damage whatsoever which may result from the failure of this product Any and all warranties of m...