Parasound D/AC-1100 HD Owner'S Manual Download Page 6

-6-

Rewiring for 220-240 V 50 Hz Operation

The D/AC-1100 HD can be rewired for operation abroad. Please refer this conversion to a skilled
electronics technician to avoid injury or possible harm to the unit.

The main power supply printed circuit board has three separate power transformers. Nearby the
transformers you will find jumper wires that correspond to the various primary windings of each power
transformer.

A total of six jumper wires are connected to the circuit board for 120 V operation.  Two jumpers are
connected near each transformer; each jumper has 120 V printed alongside it on the circuit board.

Only 3 jumpers are connected to the circuit board for 220-240 V operation  One jumper is connected
near each transformer; each jumper has 220 V printed alongside it on the circuit board.

For 220-240 V operation, you must also disconnect the six 120 V jumpers.

Parasound Limited Warranty  (USA only)

Parasound Products, Inc. warrants products purchased from authorized Parasound Dealers and Custom
Installers to the original owner for two years from the date of purchase. In the event of a defect in
materials or workmanship, the product will be repaired promptly without charge. At Parasound’s option,
product may be replaced with new product of equal or superior value to the defective product according
to the condition that it was received by Parasound.

The warranty excludes parts subject to normal wear such as fuses, laser pickups, or cosmetic parts.

The warranty also excludes damage resulting from abuse, shipping damages, failure to use products
within specifications or instructions.

The warranty is void in the event of unauthorized repair or modification, removal or defacing of the
serial number.

Dealer stock will be warranted to a maximum of 2 years from date of purchase.

In no case will Parasound accept warranty claims for any purchaser’s unit after 38 months from date of
original dealer’s purchase from Parasound.

For Returns:  Call, write, or fax Parasound’s Technical Services Department. If it is decided that the
unit should be returned for inspection at Parasound, it must be packed in its original carton as well as an
additional outer carton. An RA number will be issued which must appear on the outer carton. A note
stating the nature of the defect should accompany the unit. Units that arrive with evidence of
mispacking (internal rattling, damaged carton) will be refused by Parasound.

HDCD

  

and High Definition Compatible Digital

 

are registered trademarks of Pacific Microsonics, Inc.

ST’ is a registered trademark of AT&T Corporation

Parasound Products, Inc. 950 Battery Street, San Francisco, CA 94111

415-397-7100 / FAX 415-397-0144

Summary of Contents for D/AC-1100 HD

Page 1: ... of your D AC 1100 HD carefully and inspect the unit for possible shipping damage Report any damage to your dealer immediately You will find the detachable AC line cord packed separately inside the carton Save the plastic bag inserts and carton You may need these later for transporting the D AC 1100 HD or for shipment in the event it ever requires factory service Record the serial number on rear p...

Page 2: ...OSlink connectors AES EBU Balanced XLR Connection AES EBU Audio Engineering Society European Broadcast Union balanced connections have become the standard digital connection for professional digital audio equipment Balanced AES EBU XLR connectors are also becoming increasingly popular with high end consumer equipment AES EBU connections are thought to be superior to coaxial TOSlink and even ST con...

Page 3: ...main off on standard recordings Sampling Frequency LEDs Your D AC 1100HD will recognize the digital signal of whatever type of digital source you connect and will switch to the correct sampling rate automatically The 44 1 Hz sampling rate is standard for compact discs 32 Hz is for digital broadcast 48 Hz is for DAT De Emphasis LED Some digital recordings are encoded with pre emphasis contouring Yo...

Page 4: ...pack the unit in its original carton and cardboard packing plus an additional outer box for protection in transit The Return Authorization number must be clearly marked on the outer carton only You should ship the unit by UPS with adequate insurance specified You must include a copy of your purchase receipt to validate your ownership Units that arrive without your specific Return Authorization num...

Page 5: ...Input 32 kHz 4 1 kHz 48 kHz Consumer standard SPDIF Digital Filters PMD 100 High Definition Compatable Digital Digital Process Decoder Absolute Polarity 0 or 180 switchable Digital Inputs Coaxial 75 Ω RCA TOSlink fiber optic EIAJ Standard CP 340 RC 5720 660 nm typical wavelength AES EBU Balanced XLR Outputs Unbalanced Analog Line Out 3 0 V nominal 600 Ω Digital 75 Ω RCA coaxial 0 5 V peak to peak ...

Page 6: ...placed with new product of equal or superior value to the defective product according to the condition that it was received by Parasound The warranty excludes parts subject to normal wear such as fuses laser pickups or cosmetic parts The warranty also excludes damage resulting from abuse shipping damages failure to use products within specifications or instructions The warranty is void in the even...

Reviews: