Summary of Contents for SD1000U

Page 1: ...Parani SD1000U User Guide Version 2 0 4 2014 12 15...

Page 2: ...Users When a system failure may cause serious consequences protecting life and property against such consequences with a backup system or safety device is essential The user agrees that protection aga...

Page 3: ...ark Initial Writing V1 0 1 2011 01 04 JH Park Modify Working Distance V2 0 2 2012 01 18 JH Park Modify contents about page timeout and node switching mode V2 0 3 2012 02 24 JH Park Modify AT MULTI com...

Page 4: ...tility 16 3 10 ParaniWIN 16 3 11 ParaniUpdater 22 3 12 Terminal Program 22 4 Multiple Connection Mode 24 4 1 Overview 24 4 2 Configuration 25 4 3 AT Commands 26 4 3 1 AT MULTI n 26 4 3 2 AT MLIST 26 4...

Page 5: ...D 37 A 3 26 AT BTFP n 37 A 3 27 AT BTSEC Authentication Encryption 38 A 3 28 AT BTNAME string 38 A 3 29 AT BTLPM n 38 A 3 30 AT BTRSSI n Single Connection Mode Only 38 A 3 31 AT V 39 A 3 32 ATSnn 39 A...

Page 6: ...t Connected Device 44 B 29 S57 Slave Disconnect Timeout default 3 44 B 30 S58 MAX TX POWER default 0 44 B 31 S59 Current Slave in Communication default 0 45 B 32 S60 Reconnect Time Interval default 5...

Page 7: ...ikelihood of over air hijacking Parani SD1000U also supports authentication and data encryption Parani SD1000U can be configured and controlled by a set of AT commands Users can easily configure Paran...

Page 8: ...imited warranty Note Bluetooth v2 0 supports improved AFH function AFH function is to mitigate the interference between WiFi and Bluetooth radios by automatically avoiding the active WiFi channel from...

Page 9: ...program running on the PC 2 1 Panel Layout This section describes the panel layout of the Parani SD1000U Figure 2 1 The panel layout of Parani SD1000U 2 2 Connecting the Hardware This section describe...

Page 10: ...ip com Drivers VCP htm Supported operating systems are as follows Operating System x86 32bit x64 64bit PPC ARM MIP SII MIP SIV SH4 Windows O O X X X X X Linux O O X X X X X Mac OS X O O O X X X X Wind...

Page 11: ...Port The user can use the Parani SD1000U adapter connected as a virtual serial port after done to install the USB drivers It is possible to check the available serial port at the Device Manager of the...

Page 12: ...et to Mode0 Mode1 Parani SD1000U tries to connect the last connected Bluetooth device Parani SD1000U in Mode1 is to be a master and tries to connect the last connected Bluetooth device Parani SD1000U...

Page 13: ...ox are the factory defaults The flow control setting is configurable only through dip switch 3 4 Data Bit Parani SD1000U supports only 8 data bit In the case of 7 data bit and even odd parity use SD 8...

Page 14: ...with a narrow pointed tool like paper clip Reset works only when SD1000U is connect to usb port 3 7 Dipswitch With the combination of 4 slot dipswitches baud rate and hardware flow control can be set...

Page 15: ...h other whenever they are connected to usb port Using a pair of Parani SD1000U in this fashion is similar to that of using a wireless serial cable Note When using the pairing buttons the Command Respo...

Page 16: ...e Software Purpose Operating System ParaniWIN Configuration MS Windows 98SE or Higher ParaniUpdater Firmware Update MS Windows 98SE or Higher 3 10 ParaniWIN ParaniWIN is a program that runs on Microso...

Page 17: ...Figure 3 4 Information Window Serial port settings can be changed by Start Configuration and ParaniWIN Configuration of ParaniWIN in the menu bar at upper left corner of the window without re running...

Page 18: ...ption If you enable the Authentication option you must also enter a Pin Code value If the authentication is enabled the connection between the Master and Slave device must share the same Pin Code In c...

Page 19: ...command mode the Baud Rate menu will be disabled Click Apply button to apply any changes made to the Parani SD1000U Connection out icon will show the following window to search and connect other Bluet...

Page 20: ...STOP button at anytime in order to terminate the signal strength test The signal strength test will continue until the STOP button is pushed If you close the ParaniWIN Window without pushing the STOP...

Page 21: ...Connection Wizard icon is clicked an easy to use pairing menu will appear Figure 3 10 Connection Wizard Window In this example we will refer to the two Parani SD1000Us as SD1 and SD2 respectively To...

Page 22: ...ni SD1000U at http www sena com With the ParaniUpdater you can update the firmware of Parani SD1000U by selecting the firmware image file and pushing Start button After complete to firmware update rep...

Page 23: ...ams accessories communication HyperTerminal Select the Serial port that Parani SD1000U is connected to Select the Serial port setting in the window displayed please make sure the serial settings in Hy...

Page 24: ...e and they transfer data bi directionally as in Figure 4 1 Figure 4 2 Node Switching Mode In Node Switching Mode the master unit maintains multiple connections with maximum 4 slave units but only one...

Page 25: ...atic Connection ATD000195000001 CONNECT000195000001 OK ATD000195000002 CONNECT000195000002 OK ATD000195000003 CONNECT000195000003 OK ATD000195000004 CONNECT000195000004 ATS46 000195000001 OK ATS54 000...

Page 26: ...nnect the slave which belongs to the TASK x ATHbdaddr ATH000195000001 Disconnect the slave with specified BD address 4 3 4 ATOx ATObdaddr Using the ATO command the communication status with the last a...

Page 27: ...ons The master unit would try to connect all slave units specified by S register 46 54 55 and 56 If non existing or inactive slave addresses are entered in these S registers the overall performance wi...

Page 28: ...posure limits set forth for an uncontrolled environment This device and its antenna must not be co located or operation in conjunction with any other antenna or transmitter 5 1 3 Do not Any changes or...

Page 29: ...odulation Method GFSK Gaussian filtered Frequency Shift Keying Pi 4 DQPSK pi 4 rotated Differential Quaternary Phase Shift Keying 8DPSK 8 phase Differential Phase Shift Keying 6 5 Radio Output Power P...

Page 30: ...kinds of message OK ERROR CONNECT and DISCONNECT A 1 3 Operation Mode Mode Description Mode0 Waiting for AT commands Mode1 Attempting to connect the last connected Bluetooth device Mode2 Waiting for t...

Page 31: ...UARTCONFIG b p s BLUETOOTH Information 5 6 7 8 9 10 AT USEDIP AT BTINFO AT BTINQ AT BTLAST AT BTVER AT MLIST Mode 11 12 AT BTMODE n AT MULTI n Status 13 14 15 16 17 18 19 AT SETESC nn ATO AT BTCANCEL...

Page 32: ...quipment is operating normally The serial parameters of Parani SD must be same as those of host equipment If not the Parani SD will not respond or ERROR message will appear or an abnormal sequence of...

Page 33: ...112233445566 FriendlyName CoD 112233445566 FriendlyName CoD OK Purpose Search Bluetooth devices nearby Description The Bluetooth devices in Inquiry scan mode nearby are displayed with their BD addres...

Page 34: ...ription Set single connection mode multi drop mode or node switching mode A 3 13 Response OK Purpose Convert the operation status of Connect to Standby Description In Connect status data from host is...

Page 35: ...iry scan and Page scan then converts the operation status to Standby A 3 17 AT BTSCAN Response OK CONNECT 112233445566 Purpose Wait for inquiry and connection from other Bluetooth devices Description...

Page 36: ...en connection is made with the Bluetooth device response will be CONNECT with its BD address If there is no connection made within this time duration response is ERROR and the operation status becomes...

Page 37: ...pin code Parani SD generates a link key which is used in actual authentication process Example AT BTKEY apple A 3 24 AT BTSD Response 112233445566 OK Purpose Display a list of Bluetooth devices shari...

Page 38: ...identification The name allows up to 30 alpha numeric characters Example AT BTNAME My Parani SD A 3 29 AT BTLPM n Response OK Purpose Set low power mode Parameters n 0 Inactivate Default n 1 Activate...

Page 39: ...e displayed A 3 33 ATSnn mm Response OK Purpose Change S register value Parameters nn Address of S register mm New value of S register Description Some S registers are optimized for the overall perfor...

Page 40: ...T BTNAME Name AT BTKEY nnnn AT BTINFO AT BTLPM n AT BTSD AT BTCSD AT BTFP n AT UARTCONFIG b p s AT USEDIP AT BTVER AT BTRSSI n Valid only when Parani SD is not connected to other Bluetooth device Vali...

Page 41: ...effective Just for reference the buffer length for receiving data is 2 Kbytes B 3 S4 Enable Remote Name Query default 1 S4 0 Parani SD will query only the BD address This speeds up the inquiry process...

Page 42: ...ecides whether Bluetooth connection is released when DTR signal drops or not If this value is 1 you can use DTR signal in order to disconnect Bluetooth connection B 11 S22 Faster Connection default 0...

Page 43: ...mes the more quickly Parani SD can detect an abnormal disconnection But when the communication is suspended it may be regarded as disconnection This value should be greater than the Slave Disconnect T...

Page 44: ...ce This saves the Task3 BD address of the Bluetooth device connected most recently in a multiple connection mode B 28 S56 BD Address of Last Connected Device This saves the Task4 BD address of the Blu...

Page 45: ...0 means the maser unit never connected to a slave The master will connect to a slave whatever responses first B 32 S60 Reconnect Time Interval default 5 This value defines reconnect time interval in...

Page 46: ...by way of the dipswitch Parani SD does not support RS 232 break signal C 2 Data Loss or Malfunctioning C 2 1 Hardware Flow Control When transmitting large amounts of data with No Hardware Flow Contro...

Page 47: ...Appendix D Parani SD1000U mechanical drawing D 1 Parani SD1000U mechanical drawing mm...

Page 48: ...ES INCLUDING BUT NOT LIMITED TO DIRECT INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES WHETHER IN AN ACTION IN CONTRACT OR TORT INCLUDING NEGLIGENCE AND STRICT LIABILITY SUCH AS BUT NOT LIMITED T...

Page 49: ...y component capacity degradation due to usage aging and with some chemistry lack of maintenance E 4 SOFTWARE PRODUCT WARRANTY DETAILS WARRANTY PERIOD SENA warranties software Product for a period of o...

Reviews: