![Paramount Polymers SWACHH PIYO User Manual Download Page 4](http://html1.mh-extra.com/html/paramount-polymers/swachh-piyo/swachh-piyo_user-manual_3623743004.webp)
Rated voltage
Power consumption for normal water
1
Danger: Do not force in/out the power cable to avoid damage to the cable and
consequential danger to yourself.
2.
Do not wipe the product with water or oil to avoid damage on the product surface!
Wipe the surface with soft and dry cloth to keep clean.
3.
Danger: Do not alter power socket or overextend power cable to prevent possible
fire hazard.
4.
Danger: Do not power on/off the unit by directly plugging in/out the socket.
5.
Keep away from heater, and out of room exposed to direct sunlight, rain, or
steam. Keep away from explosive materials.
6.
Connected with pipe with the water disappear will cause the center of gravity shift
sideward, must stabilize the dispenser firmly before use.
7.
If the supply cord is damaged, it must be replaced by the manufacture or seller, or
its service agent or similarly qualified persons in order to avoid hazard.
8.
The product is for household use only.
9.
This appliance is not intended for use by persons(include children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
10. Children should be supervised to ensure that they do not play with the appliance.
All tanks and pipes had received in factory sterilizing treatment, but user
are advised to clean them on a regular basis.
1. Regular cleaning: Keep the product heating for 30 minutes, the turn off
the ball valve, switch off power source, open draining cap and 2 taps to
release residual water(Caution: Avoid direct contact with hot water because
scald may occur).
Not work
No pure water or
waste water while
it is working
Pure water flow is
very small
Waste water is too
much or only waste
water
Taste is bad
Abnormal voice
Water heating
Pure water TDS
valve is abnormal
1. No power
2. Transformer damaged or did not
connected well
3. High pressure or low pressure which
damaged
4. Pump damaged
5. Water pressure is low
1. Pre-filter before RO membrane is
blocked
2. RO membrane is blocked
PE pipe band badly or fixing is blocked
1. Filter is blocked
2. RO membrane is blocked
3. Water temperature is very cold
4. PE pipe band badly
5. Pump is damaged
1. Power connect is not well (Auto flush
will finishing 30 seconds while start
2. Check valve both pressure
1. UOF and T33 flours life worked overtime
2. It stops working for long time
3. RO membrane blocked or breaking
1. Pipe line had air inside
2. Pump abnormal voice
1. Pump water leaking
2. Filling water leaking
3. T33 flour water leaking
4. RO membrane water leaking
1. RO membrane is damaged
2. RO membrane housing is damaged
3. RO membrane small ring is damaged
4. Not work for long time
1. Plug in power
2. Replace transformer or connect it well
3. Replace high pressure or low pressure
switch
4. Replace pump
5. Increase up water pressure
1. Replace the filter
2. Flushing the RO membrane, if invalid
please replace the RO membrane
3. Check the PE pipe and fittings, remove
blocking
1. Clean or replace the filters
2. Clean or replace RO membrane
3. Increase the water temperature andprotect it well
4. Check the PE pipe line, remove blocking
5. replace the pump
1. Connect the power well
2. Replace check valve
1. Replace UOF and T33 filters
2. Clean filters, replace the filters is invalid
3. Flush or replace the RO membrane
1. Tight the pipe line well again and
drain the air
2. Smaller abnormal voice can solved
by adjust the pump fixing screws,
or replace the pump
1. Replace the pump
2. Replace the fittings
3. Replace T33 filter
4. Replace membrane housing
1. Replace RO membrane
2. Replace RO membrane housing
3. Replace RO membrane seal ring is
damaged
4. Drain the water in the tanks and flush
1. Shot off the water supply ball valve of 5-7 stage water purifier.
2. Open the tap