SDX2 Retro

High Flow Safety Drain for Concrete

Installation Manual

Contents

Safety Instructions..................1
Introduction............................3
Installation.............................4
Bulb Replacement.................14
Troubleshooting....................16
Replacement Parts.................17
Warranty................................19

 004-027-8746-00 R04 

ECN_2418 PUB062823

VGB Compliant ANSI/APSP/ICC-16 2017 LISTED

USE ONLY PARAMOUNT GENUINE REPLACEMENT PARTS

Summary of Contents for SDX 2

Page 1: ...afety Drain for Concrete Installation Manual Contents Safety Instructions 1 Introduction 3 Installation 4 Bulb Replacement 14 Troubleshooting 16 Replacement Parts 17 Warranty 19 004 027 8746 00 R04 EC...

Page 2: ...t from hair entanglement or limb entrap ment Keep clear of pool and spa drains Hair sucked into pool or spa drains will tangle and knot trapping the swimmer under water Avoid placing your hair near a...

Page 3: ...ing drain cover This could result in swelling of the limb and or trapping a swimmer underwater Avoid mechanical entrapment of jewelry swimsuit hair decorations finger toe or knuckle in a drain pipe wi...

Page 4: ...following issues when designing and installing a proper filtration system Properly bond grounded pumps time clocks switches and any other metal in or near water This is required to address Electrical...

Page 5: ...water See parts breakdown at end of this manual for specific compo nent service life notations Any SOFA component that is severely faded chalking or brittle when flexed shall be replaced even if it h...

Page 6: ...ty The SDX2 cover and support materials are far more durable than ABS the typical plastic used in swimming pool drain covers In addition to fading the Buna in ABS is prone to UV degrada tion resulting...

Page 7: ...l require reevaluation of the cover grate and sump to ensure that the flow rating of the Suction Outlet Fitting Assembly SOFA is not exceeded Compliance with this standard requires that these SO FA co...

Page 8: ...Wall Min Flow Rating of Each Cover Max System Flow Rate One SDX2 High Flow Safety Drain 180 gpm 681 lpm 140 gpm 529 lpm 100 Two SDX2 High Flow Safety Drains 180 gpm 681 lpm 140 gpm 529 lpm 100 Three...

Page 9: ...Disable the Single Outlet provided the system piping and skimmer s shall be capable of handling the full system flow and minimum turnover rates are achieved Installation NOTICE The pipe size must to a...

Page 10: ...d the suction pipe which ring does not have threaded screw hole inserts or the pool or spa surface has an indented sump without threaded screw hole inserts and the distance between the pool or spa sur...

Page 11: ...the handle of wire strippers cut screw to the correct length 3 Install screw through the support plate into the sump until the support plate is snug to the pool surface and there is no gap behind the...

Page 12: ...trimmed flush for the part to fit snugly in the support plate WARNING FAILURE TO PROPERLY INSTALL THE PLUGS COULD DISABLE THE SAFETY FEA TURES OF THE SDX2 RETRO Fig 10 5 Attach the drain cover to the...

Page 13: ...ONLY PARAMOUNT GENUINE REPLACEMENT PARTS 12 Fig 11 Trim tabs flush to fit in support plate Fig 10 Attached without spacers and threaded inserts Attached with both spacers and threaded inserts A B Fig...

Page 14: ...cludes Screws Trim Pack TORX Wrench T 25 Security Replace cover within 5 installed years Please indicate your color choice by placing the appropriate color code in place of the XX at the end of the pa...