
29
Troubleshooting Guide for
Paramount In-Floor Systems
Problem
Diagnosis
Solution
The water valve
stays on one
circuit. One
circuit of nozzles
running constantly
and not switching.
• Run/Pause switch is in the
pause position.
• The module gear mechanism
could be jammed.
• System could have incor-
rectly sized nozzles
• System could have a plugged
circuit
• Turn the run/pause switch to
run.
• Take the module out of the
water valve (refer to Water
Valve Instructions) and con-
firm that the gear mechanisms
turn freely. If it does not, re-
move all debris. If it still does
not work, replace the module.
• Check for pressure above
25 psi (172 kPa) at the water
valve. If the pressure does
not change or changes very
slowly (longer than 3 min-
utes) and if the nozzle(s) have
been removed they may have
been replaced in the wrong
locations. Nozzle(s) are size
and location specific to your
system.
• Remove nozzle(s) refer to
the Nozzle/Installation and
Removal section. Turn the
system pump on to blow out
the circuit. Replace Nozzle(s).
It is always best to call a trained professional to service your pool
Further information on your cleaning system can be found at: www.1paramount.com