OPERATION INSTR UCTIONS
Leak Check
1. Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts water).
2. Apply several drops of solution where hose attaches to regulator.
3. Apply several drops of solution where regulator connects to cylinder.
4. Make sure all fire pit and light valves are OFF.
5. Turn cylinder valve ON
If bubbles appear at any connection, there is a leak.
1. Turn cylinder valve OFF
2. If leak is at hose/regulator connection: tighten connection and perform another leak test. If bubbles
continue appearing, the hose should be returned to the place of purchase.
3. If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform another leak
check. If you continue to see bubbles after several attempts, cylinder valve is defective and should be
returned to cylinder´s place of purchase
If NO bubbles appear at any connection, the connections are secure.
NOTE:
Whenever gas connections are loosened or removed, you
must
perform
a
complete
leak
test
Complete installation
Regulator / Cylinder
connection
Hose / Regulator
connection
·Perform all leak tests outdoors
·Extinguish all open flames.
·NEVER leak test when smoking.
·
een
Do not use the fire pit until all connections have b
leak tested and do not leak.
WARNING
13