background image

User Manual - 

Typhoon Open – 

12/2013 edition

                                           

                                                                                 

 

                                                                                                                                                                               

 

 

                             .   

PARAMINA SA 

– Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1 

                                       Fax: 0030 210 5575868, email: 

[email protected]

 - website: 

www.paramina-compressors.com

 

       

 

   7                                                                                                                                                                        

 

 

 

 

 

Special attention 

 

 

Do not use the compressor in explosive environment. 

  Connect the compressor only to electrical systems that are compatible with its electrical characteristics 

and that are with in it’s rated capacity 

  Comply with the local mains supply company regulations. 

  Use only the recommended fuses. 

  A trained electrician may only execute maintenance in the electrical system. 

  During  any  maintenance  work  in  the  unit,  turn  off  the  power  from  the  mains.  It  is  also  recommended 

posting a notice warning about maintenance works on the compressor. 

  In  case  of  having  to  execute  maintenance  works  on  an  operating  unit,  a  second  person  beside  the 

electrician must be present to handle the main safety switch or the Emergency Stop. Tools to be used 
must be isolated. 

  Regularly check hoses, couplings and fittings for leaks and loose connections. 

  Regularly check tightening of the electrical connections. 

  If you replace any cable, you must use the same type. 

  Decompress  all  hoses,  filters,  pressure  tanks  and,  basically,  the  entire  unit,  before  you  carry  out  any 

work. 

  Never exceed the allowed operating pressure of the cylinders. 

  Immediately replace cylinders with any kind of damage. 

  Do not heat the cylinders or any of their parts, because pressure will rise. 

  For loading 

– lifting of the unit or heavy parts of it, use the proper lift truck that is handled by trained 

stuff. 

  Make sure you have properly secured the unit during its elevation or transport. 

  The  compressor  is  not  made  for  use  by  the  sea.  In  such  a  case,  spray  the  unit  with  anticorrosive 

material. Portable compressors (if used on a boat/ship) must be stored under the deck after use. 

 
 
 

 

Safety Regulations 

 
The 

PARAMINA 

Typhoon

 

Open

 compressor is a high pressure air-compressor and it is made according 

to EU directive 2006/42/EC for the safety of machinery. Noise complies with 2000/14 EC directive. 
 
The manufacturer follows all regulations above and declares that the unit is manufactured accordingly. 
 
Following  the  safety  regulations,  an  authorized  professional  in  site must  supervise  compressors  that  will 
be used as filling stations before starting their operation. 
 
 
 

 

Summary of Contents for Typhoon Open 15D

Page 1: ...n Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 1 USER M...

Page 2: ...n Operation General specifications 8 Installation First start of the compressor 8 Electric version 9 Petrol version 10 Cylinder filling procedure 11 Automatic stop system 12 Dual pressure filling modu...

Page 3: ...this product Fail to observe these instructions may lead to serious injury or even death The manufacturer accepts no liability for damage or injury due to non compliance to all instructions of this m...

Page 4: ...0 m 3 h 250 lit min Maximum ambient temperature 45 C Oil capacity 2 2 lit Speed Rotation 1100 rpm 1300 rpm 1100 rpm 1300 rpm 1100 rpm Piston stroke 60 mm Cylinder bore 1 st stage 80 mm 2 nd stage 36 m...

Page 5: ...VOLTAGE Risk of electric shock Maintenance work to be carried out only by a trained electrician DIRECTION OF ROTATION Make sure for the proper direction of rotation USER INSTRUCTIONS Users must read...

Page 6: ...s for safe operation risks Check the unit on the inside and outside on a daily basis in order to make sure it is in good working condition Do not start the operation of the unit if you do not ensure y...

Page 7: ...y check tightening of the electrical connections If you replace any cable you must use the same type Decompress all hoses filters pressure tanks and basically the entire unit before you carry out any...

Page 8: ...tents of this manual so as to have full knowledge of the product 1 Choose carefully the installation place of the compressor The place must not be burdened by unfavorable environmental conditions toxi...

Page 9: ...out the electrical connections First start 1 Press the reset button if activated 4 2 Press the Start button 1 3 Immediately after switching on the system for the first time check the direction of the...

Page 10: ...he engine turn on the drain switch 2 ENGINE STOP When the final pressure is reached turn the key to position ON so as to stop the compressor and then to position OFF so as to cut the power from the ba...

Page 11: ...to DIN 477 INTERNATIONAL A Clamp Adaptor For pressures at 330 bar only the use of filling hose connector according to DIN 477 with different thread than the one at 220 bar is allowed Use of any kind o...

Page 12: ...wing the same procedure and fill until the maximum filling pressure Never open the filling hose connector valve unless the cylinder is connected to the filling hose Hose whipping due to pressurized ai...

Page 13: ...e and the BA filter The drains are controlled electronically and open automatically The user can adjust the interval time 4 from 0 5 45 min and the discharge time 3 from 0 5 10 sec Max operating press...

Page 14: ...nts should normally be in their place Let the compressor cool down Start the compressor and spray some compressor oil 5 6 c c in the suction while in operation Do not let the compressor heat up stop i...

Page 15: ...oil level through the oil sight glass 1 before every start of the compressor The level should always be at the top of the sight glass leaving a small air bubble at the top of the glass While the compr...

Page 16: ...MINA compressors operate at environmental temperatures from 5 0 C to 45 0 C Higher temperatures could cause changes in the quality of breathing air lower temperatures may cause a malfunction CAUTION B...

Page 17: ...ch on the cartridge connector while unscrewing the cartridges 3 Lay a small amount of silicone grease on the o ring of the filter s base If there is a trace of damage on the o ring replace 4 Remove th...

Page 18: ...he filter s base If there is a trace of damage on the o ring replace 5 Install the new coalescing cartridge on filter s base by fastening it down with your hand 6 Wrap a small amount of Teflon around...

Page 19: ...Filter s part numbers Part Nr Description Qty 208000022 Filter housing 1 208000002 Filter base 1 137000040 AC MS cartridge active carbon molecular sieve 2 137000090 AC MS HP cartridge active carbon mo...

Page 20: ...210 5575868 email service paramina gr website www paramina compressors com 20 Air Flow Diagram Item Description 1 Air inlet 2 Coalescing cartridge 3 Connector 4 Tube connector 5 Purifier 1 42x180 AC...

Page 21: ...th 6 Remove the new A C M S cartridge from their protective case Be sure that packaging is not punctured If it is damaged do not use it 7 Lay a small amount of silicone grease on the o ring of the new...

Page 22: ...ilter s base If there is a trace of damage on the o rings replace 9 Install the new coalescing cartridge on filter s base by fastening it down with your hand 10 Wrap a small amount of Teflon around th...

Page 23: ...ADJOINED ON TOP WHEN REINSTALLING BA Filter s part numbers Part Nr Description Qty 208611492 Filter complete 1 208620002 Filter housing aluminum 1 208620022 Filter base 1 208620012 Filter head 1 13700...

Page 24: ...hoon Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 24 Ai...

Page 25: ...0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 25 BA Cartridge lifetime BA cartridge lifetime may change as humidity temperature levels change...

Page 26: ...eplace the BA cartridge Filter 110 x 495 Open 15 35 hrs X Open 18 28 hrs X Replace the coalescing cartridge X X Check Valves X Replace Valves X Replace pistons and piston rings X Replace filling hoses...

Page 27: ...compressors com 27 Maintenance Calendar Operating Hours Check V Belt tension Change oil Change Air Filter Change Coalescing pre filter Change BA filter Check Valves Pistons and piston rings Date Sign...

Page 28: ...leaking 1 Tighten and reseal 2 Premature opening of final safety valve 2 Clean final safety valve and readjust 3 Excessive piston clearance 3 Replace and regulate again 4 The safety lock opens premat...

Page 29: ...listrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 29 6 Spare Parts Catalog Electric Version Image 1 1 3 5...

Page 30: ...stage 80 bar N O 1 8 2 140000080 Filling hose 1 9 1 190000240 1 st stage intercooler 1 10 1 103030072 Electric Motor 5 5kW 103030102 Electric Motor 7 5kW 1 11 4 128703012 Anti vibration pads 1 12 1 21...

Page 31: ...alarm option 2 5 1 177747072 High Temperature alarm option 2 6 1 177747072 Thermal switch enabled 2 7 1 163000102 Hour meter 2 8 1 109000032 Exhaust filter 2 9 1 211640041 Oil sight glass 2 10 2 1900...

Page 32: ...as str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 32 Petrol Version Image 3 2 3 4 1 8 7 10 15 6 11 12 13 14 17...

Page 33: ...004522 3 rd Stage Safety valve 350 bar 3 9 1 154122241 Auto drain 2 nd stage 80 bar 12V 3 10 1 104270092 Petrol engine 6 0 kW 1 104390132 Petrol engine 8 2 kW 3 11 4 128703012 Anti vibration pads 3 12...

Page 34: ...elistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 34 Diesel Version Image 4 2 4 1 8 7 10 15 6 11 12 13 1...

Page 35: ...uto drain 3 rd stage 350 bar 12V 4 9 1 219004552 3 rd Stage Safety valve 250 bar 1 219004522 3 rd Stage Safety valve 350 bar 4 10 1 154122241 Auto drain 2 nd stage 80 bar 12V 4 11 1 104515032 Diesel e...

Page 36: ...300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 36 Optional equipment Item Qty Part Nr Description 1 1 208704200 4 th...

Page 37: ...013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 37 Compressor Block...

Page 38: ...12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 38 Drawing 1b...

Page 39: ...20 12 211410031 Crankcase Screw M10 21 2 141600202 Piston Crosshead 2 nd 3 rd Stage 22 2 211430031 Piston Pin 2 nd 3 rd Stage 23 6 211440031 Piston Pin Lock 24 3 211530031 Crankcase Cylinder Gasket 2...

Page 40: ...Valve 3 rd Stage 53 1 154000280 Discharge Valve 3 rd Stage 54 1 127054362 O Ring Discharge Valve 3 rd Stage 55 1 190000272 Valve Head 3 rd Stage 56 1 190000282 Top Cover 3 rd Stage 57 6 193108902 All...

Page 41: ...yphoon Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 41...

Page 42: ...n 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 42 8 Cooling...

Page 43: ...anual Typhoon Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 44: ...phoon Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 44 9...

Page 45: ...anual Typhoon Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 46: ...anual Typhoon Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 47: ...anual Typhoon Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 48: ...anual Typhoon Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 49: ...anual Typhoon Open 12 2013 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Reviews: