Sync Channel from Receiver
Ú
Transmitter
STEP 1:
Press the SYNC button of the receiver.
STEP 2:
The receiver’s LCD will display
IRDA DATA SEND
to denote
synchronising signal being sent.
STEP 3:
The channel/frequency of the transmitter will change and then
the synchronisation is complete.
Sync Channel from Transmitter
Ú
Receiver
STEP 1:
Press the synchronising button of the transmitter.
STEP 2:
The transmitter’s LED will glow to denote
transmitting the frequency to the receiver and
synchronising the channels.
STEP 3:
The channel/frequency of the receiver will change
and then the synchronisation is complete.
If it doesn’t work check that you have the IR sensor panels aligned, that they are facing each other, devices are within
30cm of each other, and try again.
Channel Scanning
For an interference-free operation, a cleaner channel might be necessary if the current one receives too much
interference. Before scanning, the transmitter must be switched off.
1.
Press and release
SET
button until the AUTO SCAN page appears.
2.
Press
p
(UP) or
q
(DOWN) button to find a clear, interference-free channel. 5 seconds after selecting a channel,
it will be automatically saved.